Axion Detection with Resonant Cavities Kelsey Oliver-Mallory 1 Content Axions (why resonant cavities are an effective way to detect them) Resonant Cavities (how they work) ADMX (limits that cut into region of plausible axion


slide-1
SLIDE 1

Axion Detection with Resonant Cavities

Kelsey Oliver-Mallory

1

slide-2
SLIDE 2

Content

  • Axions (why resonant cavities are an effective way to detect them)
  • Resonant Cavities (how they work)
  • ADMX (limits that cut into region of plausible axion theories)

2

slide-3
SLIDE 3

Axions

  • pseudoscalar

dark matter candidate

  • probably light
  • probably cold

3

slide-4
SLIDE 4

Peccei-Quinn Theory

  • Strong force only breaks charge

parity

  • Strong CP problem
  • Breaks hidden global U[1]

symmetry

  • pseudo-Nambu-Goldstone boson
  • meets dark matter requirements:

cold, non-baryonic, weak coupling to normal matter

  • Forms a Bose_Einstein

condensate

4

slide-5
SLIDE 5

Mass

  • fA is the decay constant
  • constrained cosmic observation

and particle physics experiments

  • SN1987A: lower bound fA
  • cosmic energy density: upper

bound on fA

  • Axion mass in range: ueV-meV
  • Lifetime much greater than age
  • f universe

5

slide-6
SLIDE 6

Coupling to photon (KSVZ and DFSZ models)

  • is the fine structure constant
  • g is a model dependent coupling constant

6

slide-7
SLIDE 7

Inverse Primakoff Effect

  • Use B0 as a virtual photon
  • Increase decay rate by increasing external magnetic field

7

slide-8
SLIDE 8

Resonant Cavities for Axion Detection

  • Use a long

cylindrical resonant cavity

  • Apply uniform

magnetic field throughout cavity

  • Can detect

photons at resonant frequencies

8

slide-9
SLIDE 9

Resonant Cavities for Axion Detection

  • Maxwell’s equations and

boundary conditions result in standing waves

  • Only certain resonant modes

allowed

  • Energy of axion must align

with frequency of resonant mode

  • Usually looking for TM010

mode.

9

slide-10
SLIDE 10

Resonant Cavities for Axion Detection

  • Want tunable resonant

cavities

  • Position of rods

changes the resonant frequency

10

slide-11
SLIDE 11

Tuning Resonant Modes

  • Magnitude electric field

11

slide-12
SLIDE 12

Tuning Resonant Modes

  • Power produced in cavity

from axion

  • a: local energy density of

axion field

  • V: volume of the cavity
  • QL: loaded quality factor
  • Cmnp: coupling form

factor of the axion to a specific mode

12

slide-13
SLIDE 13
  • Projected limits for

ADMX move into band of viable theories.

Comparison Resonant Cavity Experiments

13

slide-14
SLIDE 14

ADMX Detector

  • Superconducting solenoid
  • 7.6 Tesla magnetic field
  • Cylindrical resonant cavity:

r=21cm and z= 100cm

  • Black body and axion

photons picked up by antenna at top of cavity

  • Cryogenically cooled

14

slide-15
SLIDE 15

ADMX Detector

15

slide-16
SLIDE 16

Receiver and Electronics

  • HFET noise temperature: 2K
  • KSVZ axions: 1.9-3.3 ueV
  • SQUID noise temperature: 100mk

at 500MHz and 200mK

  • KSVZ axions: 3.3-3.53 ueV
  • Newest version: cooling with

3He/4He dilution refrigerator

16

slide-17
SLIDE 17

SQUIDs

17

slide-18
SLIDE 18

Signal

  • Warm power spectrum

with cavity resonance

  • Monte Carlo with axions

18

slide-19
SLIDE 19

ADMX Sensitivity

19

slide-20
SLIDE 20