fe65 p2 threshold stability for atlas pixel layer upgrade
play

FE65-P2 Threshold Stability for ATLAS Pixel Layer Upgrade Katie - PowerPoint PPT Presentation

FE65-P2 Threshold Stability for ATLAS Pixel Layer Upgrade Katie Dunne July 29, 2016 Analog Islands (2x2 pixels) FE65-P2 64 x 64 Pixels 2 Quad Columns per Digital Sea flavor (8x64 pixels) 2 Katie Dunne July 29, 2016 Hybrid Pixel


  1. FE65-P2 Threshold Stability for ATLAS Pixel Layer Upgrade Katie Dunne July 29, 2016

  2. Analog Islands (2x2 pixels) FE65-P2 64 x 64 Pixels 2 Quad Columns per Digital Sea flavor (8x64 pixels) 2 Katie Dunne July 29, 2016

  3. Hybrid Pixel Detectors [e] threshold charge I mage: L.Rossi / Pixel detectors: From fundamentals to applications single readout channel 3 Katie Dunne July 29, 2016

  4. Threshold Scan Varying charge is injected ● Occupancy for each pixel at each charge ● forms a sigmoid curve Threshold s-curve mean Bad = same pixel threshold threshold value but at different inputs. Steepness-> different noise Bad Good values Wide range of inputs Inputs closer together Steepness noise Uniform noise 4 Katie Dunne July 29, 2016

  5. Tuned Threshold Threshold cont’d Small width - most pixels within mean Threshold Mean ~800e 5 Katie Dunne July 29, 2016

  6. Untuned Threshold Threshold cont’d Threshold Mean shifts Large width, chip-wide threshold can’t be described accurately 6 Katie Dunne July 29, 2016

  7. Cold/Dry Box Several chips irradiated at Los ● Alamos National Lab in Spring 2016. Tested temp between 40°C and ● Temperature -40°C HL-LHC operating temps ○ won’t vary much around -7°C Temp tests on 2 chips irradiated ● to ~150 Mrad and ~350 Mrad FE65-P2 7 Katie Dunne July 29, 2016

  8. Column Flavor 4 (RH+LCC) 20°C Tuning Column Flavor 4 (RH+LCC) -10°C 0 Mrad 0 Mrad 150 Mrad 150 Mrad 350 Mrad 350 Mrad Distributions Column Flavor 8 (LCC) 20°C Tuning Column Flavor 8 (LCC) -10°C 8 Katie Dunne July 29, 2016

  9. Results: Threshold Shift 9 Katie Dunne July 29, 2016

  10. Results: Detuning 10 Katie Dunne July 29, 2016

  11. 88” Cyclotron Irradiation June 2016 Irradiation Device installed in ● temperature and humidity secure box Ran for ~8 hours in 50 Mev ● proton beam at -10°C Beam Beam was stopped ● periodically then threshold Cold scans were taken Box Reached ~1.3 Mrad dose ● HL-LHC will reach 1 Mrad in ● 1 run (~10 hours) 11 Katie Dunne July 29, 2016

  12. Results: Threshold Shift Retuned at 1 Mrad Effect from temp increase to 20°C 12 Katie Dunne July 29, 2016

  13. Results: Detuning Effect from temp increase to 20°C Retuned at 1 Mrad 13 Katie Dunne July 29, 2016

  14. Table of rates taken from linear fit of data from 20°C to -20°C Flavors with similar features averaged together ● August irradiation will give more information ● Results 14 Katie Dunne July 29, 2016

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.