FE65-P2 Threshold Stability for ATLAS Pixel Layer Upgrade Katie - - PowerPoint PPT Presentation

fe65 p2 threshold stability for atlas pixel layer upgrade
SMART_READER_LITE
LIVE PREVIEW

FE65-P2 Threshold Stability for ATLAS Pixel Layer Upgrade Katie - - PowerPoint PPT Presentation

FE65-P2 Threshold Stability for ATLAS Pixel Layer Upgrade Katie Dunne July 29, 2016 Analog Islands (2x2 pixels) FE65-P2 64 x 64 Pixels 2 Quad Columns per Digital Sea flavor (8x64 pixels) 2 Katie Dunne July 29, 2016 Hybrid Pixel


slide-1
SLIDE 1

FE65-P2 Threshold Stability for ATLAS Pixel Layer Upgrade

Katie Dunne July 29, 2016

slide-2
SLIDE 2

FE65-P2

2 Quad Columns per flavor (8x64 pixels) Analog Islands (2x2 pixels) Digital Sea

Katie Dunne July 29, 2016

64 x 64 Pixels

2

slide-3
SLIDE 3

Katie Dunne July 29, 2016

Hybrid Pixel Detectors

single readout channel

Image: L.Rossi / Pixel detectors: From fundamentals to applications

[e]

threshold charge

3

slide-4
SLIDE 4

Threshold

Katie Dunne July 29, 2016

Threshold Scan

  • Varying charge is injected
  • Occupancy for each pixel at each charge

forms a sigmoid curve Bad

same threshold value but at different inputs. Steepness-> different noise values

Bad

Wide range of inputs Steepness noise

Good

Inputs closer together Uniform noise

s-curve mean = pixel threshold

4

slide-5
SLIDE 5

Threshold cont’d

Tuned Threshold

Small width - most pixels within mean Threshold Mean ~800e Katie Dunne July 29, 2016

5

slide-6
SLIDE 6

Katie Dunne July 29, 2016

Threshold cont’d

Untuned Threshold

Large width, chip-wide threshold can’t be described accurately Threshold Mean shifts

6

slide-7
SLIDE 7

Temperature

Katie Dunne July 29, 2016

  • Several chips irradiated at Los

Alamos National Lab in Spring 2016.

  • Tested temp between 40°C and
  • 40°C

HL-LHC operating temps won’t vary much around -7°C

  • Temp tests on 2 chips irradiated

to ~150 Mrad and ~350 Mrad

Cold/Dry Box FE65-P2

7

slide-8
SLIDE 8

Distributions

0 Mrad 150 Mrad 350 Mrad

Katie Dunne July 29, 2016 Column Flavor 4 (RH+LCC) 20°C Tuning Column Flavor 4 (RH+LCC) -10°C Column Flavor 8 (LCC) -10°C Column Flavor 8 (LCC) 20°C Tuning

0 Mrad 150 Mrad 350 Mrad

8

slide-9
SLIDE 9

Results: Threshold Shift

Katie Dunne July 29, 2016

9

slide-10
SLIDE 10

Results: Detuning

Katie Dunne July 29, 2016

10

slide-11
SLIDE 11

88” Cyclotron Irradiation

  • Device installed in

temperature and humidity secure box

  • Ran for ~8 hours in 50 Mev

proton beam at -10°C

  • Beam was stopped

periodically then threshold scans were taken

  • Reached ~1.3 Mrad dose
  • HL-LHC will reach 1 Mrad in

1 run (~10 hours)

Beam Cold Box

June 2016 Irradiation

Katie Dunne July 29, 2016

11

slide-12
SLIDE 12

Results: Threshold Shift

Katie Dunne July 29, 2016 Retuned at 1 Mrad Effect from temp increase to 20°C

12

slide-13
SLIDE 13

Results: Detuning

Katie Dunne July 29, 2016 Retuned at 1 Mrad Effect from temp increase to 20°C

13

slide-14
SLIDE 14

Results

Katie Dunne July 29, 2016

Table of rates taken from linear fit of data from 20°C to -20°C

  • Flavors with similar features averaged together
  • August irradiation will give more information

14