antineutrino detectors
play

Antineutrino Detectors Vojtech Bednar, Michaela Fendrychova - PowerPoint PPT Presentation

Report from Student Practice at JINR Testing of Scintillation Antineutrino Detectors Vojtech Bednar, Michaela Fendrychova Supevisor: V. Egorov Dzhelepov Laboratory of Nuclear Problems 25.7.2014 Testing of Scintillation Antineutrino Detectors


  1. Report from Student Practice at JINR Testing of Scintillation Antineutrino Detectors Vojtech Bednar, Michaela Fendrychova Supevisor: V. Egorov Dzhelepov Laboratory of Nuclear Problems 25.7.2014

  2. Testing of Scintillation Antineutrino Detectors 2 Antineutrino 25.7.2014

  3. Testing of Scintillation Antineutrino Detectors 3 Antineutrino 25.7.2014

  4. Testing of Scintillation Antineutrino Detectors 4 DANSS project 25.7.2014

  5. Testing of Scintillation Antineutrino Detectors 5 Detector Cube 1 m 3 from stripes (100x4x1 cm) or plates (40x20x1 cm) • Plates with different amount of pTP • Our task was to determine which are the best • 25.7.2014

  6. Testing of Scintillation Neutrino Detectors 6 Scintillator plates The best plate – the best energy resolution • Energy resolution depends on the fotoelectron yield • The number of photoelectrons per 1 MeV energy deposit was • measured Different reflective materials were examined • Responce dependence on the energy deposit position • 25.7.2014

  7. Testing of Scintillation Antineutrino Detectors 7 Measurement Signal collected with • optical fibers Troubles with • breaking of fibers 25.7.2014

  8. Testing of Scintillation Antineutrino Detectors 8 Measurement 25.7.2014

  9. Testing of Scintillation Neutrino Detectors 9 Measured spectra Response on 2,2 MeV cosmic muons • 100000 10000 1000 counts plate 100 stripe 10 1 0 200 400 600 800 1000 channel number 25.7.2014

  10. Testing of Scintillation Neutrino Detectors 10 Results Stripes: 10 PE/MeV • Plates: • 45 40 35 PE/MeV 30 none PMT1 25 none PMT2 20 aluminium 15 teflon 10 5 0 0 1 2 3 4 PTP concentration [%] 25.7.2014

  11. Testing of Scintillation Neutrino Detectors 11 Conclusion The best results for plates with 2 % - 2,5% of pTP • Plates are 4x better than stripes • Further step – effect of different POPOP concentration • 25.7.2014

  12. Thank you for your attention

  13. Questions ?

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.