1
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
AT
N
Power Systems
Photo-Voltaic Array Power Conversion Systems The information of this - - PowerPoint PPT Presentation
PowerGate TM TM AT N Power Systems Power System s Photo-Voltaic Array Power Conversion Systems The information of this document is the confidential information of SatCon Power Systems 1 SPS 05/10/04 and is not to be reproduced without
1
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
2
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
* Pending
3
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
PV Array
Controls ST 4 Line Display & Key Pad
To Utility Interface
4
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
Heavy duty 11 gauge steel enclosure Seismic Zone 4 Surfaces Primed with 2 coats of rust inhibitor & UL listed RAL 7032 Outdoor NEMA 3R Ventilation top entry, bottom exit reduces intake debris clogs Washable intake filter Input / Output disconnect sections integral to enclosure Top, bottom and side cable entries Removable gland plates for ease of installation Top lifting eye-bolts Sloped roof prevents standing water Lockable disconnect & enclosure door
5
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
PV Array Input 270-660Vdc
Controls ST
Input Contactor for sleep mode and array fault isolation Input Disconnect Eliminates on site work Adjustable DC ground fault DC Surge Protection
4 Line Display & Key Pad
6
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
Input Disconnect(s) interlocked with PCS DC Field terminals RS485 terminals Top bottom & side entry into rear power cable duct Input compartment reduces field installation time & cost Additional integrated combiners available 2 Pole disconnect for floating
7
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
PV Array
Controls ST 4 Line Display & Key Pad
PV Inverter per UL 1741 & IEEE P1547 AC fuse protection with indicators for diagnostics
8
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
9
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
Backwards Impeller Blower One blower for entire system cooling reduces moving parts failures Thermostatically controlled Continuously rated for 5 years 50 C rated Thermally protected Low noise & high efficiency Diminished flow detected by reliable differential pressure switch
10
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
PV Array
Controls ST 4 Line Display & Key Pad
Fiber optic gating & feedback diagnostics
Building Management or Data Acquisition System (if used) RS485 ModBus
11
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
Common Controls Platform used in all SatCon PCS s Proven track record in over 50MW worth of military frequency converters and 20MW worth of alternative energy PCS s Advanced DSP & FPGA Controls for Leading Performance and High Reliability Versatile programming allows parameter adjustments to suit varying customer demands On board RS485 communication port Low sleep mode power consumption increases net energy delivered to the grid All PCB s are conformally coated, manufactured to IPC-A-610 class 3 industrial controls
12
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
13
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
Highly accurate peak power tracking, samples every line cycle and changes every 0.5 sec. Fast responding algorithm responds to cloud cover, prevents array voltage collapse, increasing power production run time. Intelligent wake up and sleep algorithms at dusk and dawn squeeze out maximum kWhr exported Automatic grid synchronization and reconnect on grid restoration PowerGate s software is certified for UL1741 anti-island detection on numerous gird connect applications Remote control functions: Enable / disable PCS E-Stop PCS reset VAR Control
14
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
PV Array
Controls ST 4 Line Display & Key Pad
NC Remote Trip contact High Efficiency Transformer Line Isolation Breaker with Shunt Trip Line Contactor Eliminates transformer magnetizing losses when in sleep mode. Soft Charge Network Limits inrush current To Utility Interface AC Surge Protection
15
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
High efficiency transformer and low loss line inductor with 1.10service factor, 220 C rated Transformer may be converted for various line frequency and voltages Transformer option available with taps to extend lower DC input voltage operation Easily accessible component layout, reduces MTTR Screened NEMA 3R exhaust
16
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
17
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
PV Array Input 270-660Vdc
Controls ST NC Remote Trip contact High Efficiency Transformer Line Isolation Breaker with Shunt Trip Line Contactor Eliminates transformer magnetizing losses when in sleep mode. Soft Charge Network Limits inrush current PV Inverter per UL 1741 & IEEE P1547. Uses Film type capacitors for long life. To Utility Interface Input Contactor for sleep mode isolation Input Disconnect Eliminates on site work Building Management or Data Acquisition System (if used) RS485 ModBus
Adjustable DC ground fault DC Surge Protection AC Surge Protection 4 Line Display & Key Pad
18
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
19
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems
Photovoltaic Battery Energy Storage Fuel Cell Wind Turbine Micro Turbine T G Flywheel Energy Storage AC Loads DC Loads
20
The information of this document is the confidential information of SatCon Power Systems SPS 05/10/04 and is not to be reproduced without written permission by SatCon Power Systems
Power Systems