Stab able le Rel eliabl iable Cons
- nsis
istent nt Rep epeat eatabl ble Effici icien ent Cos
- st Effe
Effectiv ive Long L
- ng Life
Introducing - cy High igh Accu Accura racy VEN PRO ROVEN ROI - - PDF document
le Stab able iable Rel eliabl nt Cons onsis istent ble Rep epeat eatabl ent Effici icien ive Cos ost Effe Effectiv ife Long L ong Life Introducing - cy High igh Accu Accura racy VEN PRO ROVEN ROI Easily Achieved in the 1st
Header Pressure Swing – 14 PSI 115 PSI 101 PSI Larger Compressor - 2nd Shift
BLUE | HEADER & PLANT PRESSURE BLACK RED ORANGE PINK | COMPRESSOR CURRENT DRAW
Plant and Header pressure experiences a
14 PSI swing.
2nd shift experiences a 14 PSI pressure
drop across the filters affecting plant delivery.
The two large compressors (75hp & 125hp)
constantly battle for control resulting in increased current draw and excessive compressor operation.
The compressors struggle to maintain a
buffer in the tank - thus, eliminating all potential capacitance.
During 2nd shift, the 125hp compressor
load-on-load cycle runs constantly.
The rate of decay is virtually instantaneous,
increasing overall workload across the two large compressors.
2 | PROPORTIONAIR.COM • Call Now for Application Assistance 877.331.1738
In fact, the company represented in these graphs was one
installing the Proportion-Air Pro-Air Mizer.
The energy cost of a compressor is roughly 10% of the #KW Example: 250KW compressor cost € 25 per/hour to operate. With Pro-Air Mizer, a 7% energy savings is easily attainable. Savings: 2,500 operating hours saves € 4,375 per year on energy costs alone! Plus: Less maintenance and longer lifetime In The United States In Europe & The World
Control - Set at 85 PSI Proportion-Air’s
1550 Gal. Receiver Volume Changes with Plant Demand
Steady, Reliable and Repeatable - Header System Pressure
Smaller Compressor - 2nd Shift Energy Savings
PROPORTIONAIR.COM • Call Now for Application Assistance 877.331.1738 | 3 Header pressure maintains a buffer and remains
stable and consistent, thus providing optimal capacitance.
Average amp draw is greatly decreased. All three compressors work together and share
the load/demand cycles while decreasing current draw and increasing pump life.
2nd shift maintains optimal header and plant
pressure using the smaller compressor alone.
Plant pressure is set at 85 psi and the Pro-Air
Mizer delivers 85 psi to all drops with virtually zero variance for both shifts.
Artificial demand is eliminated and excess
capacity is stored as reserve energy. WHAT TO EXPECT with
±0.2% of Full Scale
Up to 10,000 SCFM
Rebates, Energy Savings and Consistent Products
Lowest Cost Solution
CONTROL PACKAGE COMPONENTS & POTENTIAL RANGES
Electro-Pneumatic Pressure Regulator (QB2 shown) Up to 1000 psig (69 bar) direct control available DS Pressure Transducer Accuracy up to ±0.2% (DSY Shown) Volume Booster (R-Series Shown) Flows up to 10,000 SCFM (4,720 lit/sec) Control Box (box is optional)
ISO 9001-2008 Certified