Rate Indicator/Dual Totalizer
with Modbus and Data Logging
Hoffer Flow Controls, Inc.
Introducing Introducing … ….. .. HIT HIT-
- 4U
4U
Revised 03/07/2018 Revised 03/07/2018
Introducing .. .. Introducing HIT- -4U 4U HIT Revised - - PowerPoint PPT Presentation
Hoffer Flow Controls, Inc. Introducing .. .. Introducing HIT- -4U 4U HIT Revised 03/07/2018 Revised 03/07/2018 Rate Indicator/Dual Totalizer with Modbus and Data Logging HIT- -4U Key Features 4U Key Features HIT 11 Key Features
Hoffer Flow Controls, Inc.
Revised 03/07/2018 Revised 03/07/2018
Feature #1
LCD display for Total, Flow Rate, and Grand Total
Feature #2
Large character height. 3/8” for Total ½” for Rate
Feature #3
Full operation with magnetic pointer thru ex-enclosure
Feature #4
Data Logging: Hourly Total, Daily Total, Event Logs
Feature #6
Two Two-
Way/Active MODBUS MODBUS Communication Communication via RS485 via RS485
Feature #5
20 Point 20 Point Linearization Linearization
Feature #7
4 4 – – 20 mA 20 mA Analog Analog Output Output
Feature #9
Dual set point Dual set point Alarm Output Alarm Output
Feature #8
Scaled Pulse Scaled Pulse Output Output
Feature #10
Internal 3.6V Internal 3.6V C C-
Size battery backup backup
Feature # 11
Configuration and Total stored in non-volatile memory
Magnetic Reset Switch Magnetic Reset Switch Total Total Flow Rate Flow Rate Magnetic Menu Magnetic Menu Switches Switches
Loop Powered 8 to 30 Vdc 8 to 30 Vdc Battery powered 2 x C-size 2 x C-size Total 8 digit 8 digit Rate 6 digit 5 digit Operating temperature
Inputs MAG, Isolated Pulse & RF MAG, Isolated Pulse
Grand Total 8 digits n/a Total Units GAL, LIT, ACF, ACFx1000, M3, BBL, *Mass units: KG, LB, SCF, NM3 GAL, LIT, FT3, M3, BBL Linearization 20 points 20 points Pulse Out 0-5V (TTL), OC OC Alarm Out 0-5V (TTL), OC Hi, Lo, Dual Set Point Rate or Total OC Hi, Lo Rate or Total
HIT-4U HIT-2A
Data Logging 768 Hourly Logs 378 Daily Logs 345 Event Logs N/A Communication RS485, MODBUS RTU RS232, Proprietary Magnetic pointer allows operation without opening Ex enclosure All front panel functions, configuration, reading last 100 logs Only Reset
M
LOW BAT x1000
UNCOMPENSATED
GAL L LB KG ACF M3 SCF NM3 BBL /MIN /HR /DAY
Total Rate Operate Mode: Enters Configuration Mode Configuration Mode: Scrolls through menus Accepts numerical entry Operate Mode: Saves Totals Configuration Mode: Selects group of menus Selects value for each menu Moves to the next digit Operate Mode: Displays Grand Total Configuration Mode: Moves one level up Increments digits
Flow Rate Flow Rate Alarm Alarm Output Output Min Flow Min Flow Max Flow Max Flow
Alarm ON Alarm ON Alarm ON Alarm ON Alarm OFF Alarm OFF
RS RS-
485 to USB Adapter Adapter
Records Records Date, Date, Time, Time, Total Total flow flow and and Run time Run time Records configuration Records configuration parameters affecting parameters affecting measurement measurement
Operating -40 to +80 C Operating -40 to +70 C DC Power/ Loop/AC + Battery DC Power/Loop + Battery Analog Output 4-20mA Analog Output 4-20mA Raw frequency and Scaled Pulse Out: 0-5V TTL, OC Relay Raw frequency OC N/A with analog output Dual Set Alarm None Grand Total (non-resettable) None Full operation without
Reset total only
ENCLOSURE ENCLOSURE INPUT POWER INPUT POWER MOUNTING MOUNTING PULSE INPUT PULSE INPUT ALARM ALARM COMPENSATION METHOD COMPENSATION METHOD COMMUNICATION PORT COMMUNICATION PORT PULSE OUTPUT PULSE OUTPUT SPECIAL FEATURES SPECIAL FEATURES
SEE PRICE LIST FOR FULL DETAILS ON FEATURE COMBINATIONS
ENCLOSURE
(2) NEMA 4X (2) NEMA 4X OPTIONS FOR ENCLOSURE STYLE 3 AND 7 OPTIONS FOR ENCLOSURE STYLE 3 AND 7 (3) EXPLOSION (3) EXPLOSION-
PROOF (_M) M20 CONDUIT THREAD (NOT ALLOWED FOR USE (_M) M20 CONDUIT THREAD (NOT ALLOWED FOR USE (7) STAINLESS STEEL EXPLOSION (7) STAINLESS STEEL EXPLOSION-
PROOF IN CANADA IN CANADA (P) PANEL MOUNT (P) PANEL MOUNT – – IP40 IP40 (_S) SUNSHADE (_S) SUNSHADE (PD) PANEL MOUNT WITH CLEAR DOOR W/LOCK (PD) PANEL MOUNT WITH CLEAR DOOR W/LOCK (PF) PANEL MOUNT W/CLEAR FLEXIBLE PVC COVER (PF) PANEL MOUNT W/CLEAR FLEXIBLE PVC COVER
INPUT POWER
(B) BATTERY POWERED (B) BATTERY POWERED (L) 4 (L) 4-
20 MA LOOP POWERED (D) 12 TO 30 VDC EXTERNAL POWER (D) 12 TO 30 VDC EXTERNAL POWER (AC_) UNIVERSAL 100 (AC_) UNIVERSAL 100-
240 VAC @ 0.15A 50/60 HZ
PULSE INPUT
(M) MAG COIL (M) MAG COIL (R) ISOLATED PULSE, RPM, RPR, HALL EFFECT COILS (R) ISOLATED PULSE, RPM, RPR, HALL EFFECT COILS (RF) MODULATED CARRIER COIL (RF) MODULATED CARRIER COIL
SEE PRICE LIST FOR FULL DETAILS ON FEATURE COMBINATIONS
PULSE OUTPUT
(5*) 0 (5*) 0-
5 V TTL/CMOS (OC*) OPEN COLLECTOR (OC*) OPEN COLLECTOR * INSERT (R) FOR RAW FREQUENCY PULSE OUTPUT * INSERT (R) FOR RAW FREQUENCY PULSE OUTPUT
ALARM
(5) 0 (5) 0-
5 V TTL/CMOS (OC) OPEN COLLECTOR (OC) OPEN COLLECTOR
COMPENSATION METHOD
(X) NONE (X) NONE
MOUNTING
(X) REMOTE MOUNTING (X) REMOTE MOUNTING¹ ¹ (FX) STYLE 3 ENCLOSURE NOT CERTIFIED FOR HAZARDOUS AREA (FX) STYLE 3 ENCLOSURE NOT CERTIFIED FOR HAZARDOUS AREA MOUNTED ON METER WITH X MOUNTED ON METER WITH X-
RISER. (FXHT) STYLE 3 NOT CERTIFIED FOR HAZARDOUS AREA WITH HIGH (FXHT) STYLE 3 NOT CERTIFIED FOR HAZARDOUS AREA WITH HIGH-
TEMPERATURE 8” ” RISER. X
RISER REQUIRED ON METER. (F) STYLE 2 ENCLOSURE MOUNTED ON METER WITH X (F) STYLE 2 ENCLOSURE MOUNTED ON METER WITH X-
RISER. (FHT) STYLE 2 ENCLOSURE WITH 8 (FHT) STYLE 2 ENCLOSURE WITH 8” ” HIGH TEMPERATURE RISER HIGH TEMPERATURE RISER MOUNTED ON METER. X MOUNTED ON METER. X-
RISER REQUIRED ON METER. (NP) NEMA 4X ENCLOSURE PIPE MOUNTING KIT. 2 (NP) NEMA 4X ENCLOSURE PIPE MOUNTING KIT. 2” ” PIPE OR SMALLER. PIPE OR SMALLER. NOTE 1 NOTE 1 – – REMOTE MOUNTING IS REQUIRED FOR CERTIFIED HAZLOC REMOTE MOUNTING IS REQUIRED FOR CERTIFIED HAZLOC INSTALLATIONS FOR THE FOLLOWING AMBIENT TEMPERATURE RANGES: INSTALLATIONS FOR THE FOLLOWING AMBIENT TEMPERATURE RANGES: HIT4: < HIT4: < -
40° °C AND > +78 C AND > +78° °C C
MOUNTING – – CONTINUED CONTINUED
– – SYSTEM HAZARDOUS AREA CERTIFIED MOUNTING OPTIONS FOR STYLE SYSTEM HAZARDOUS AREA CERTIFIED MOUNTING OPTIONS FOR STYLE 3 AND 7 ENCLOSURES ONLY. 3 AND 7 ENCLOSURES ONLY. (MX_) METER MOUNTED. USED WITH STANDARD X (MX_) METER MOUNTED. USED WITH STANDARD X-
RISER (MA_) METER MOUNTED. USED WITH ATEX X (MA_) METER MOUNTED. USED WITH ATEX X-
RISER (RX_) REMOTE MOUNTED. (USE C (RX_) REMOTE MOUNTED. (USE C-
EXP OPTION ON METER) (RA_) REMOTE MOUNTED. USE WITH ATEX X (RA_) REMOTE MOUNTED. USE WITH ATEX X-
RISER & E2 ENCLOSURE ON METER. METER. UNION OPTIONS UNION OPTIONS (__U1) 1 (__U1) 1” ” MALE X 1 MALE X 1” ” FEMALE EX FEMALE EX-
PROOF UNION. USE WITH MX & RX OPTIONS OPTIONS (__U2) (__U2) ¾” ¾” MALE X MALE X ¾” ¾” FEMALE EX FEMALE EX-
PROOF UNION. USE WITH MA & RA OPTIONS. OPTIONS.
COMMUNICATION PORT
(T) INTERNAL TERMINAL BLOCK (T) INTERNAL TERMINAL BLOCK (U) EXTERNAL USB STYLE CONNECTOR (NEMA 4X ENCLOSURE ONLY) (U) EXTERNAL USB STYLE CONNECTOR (NEMA 4X ENCLOSURE ONLY) (X) NONE (X) NONE
SPECIAL FEATURES
(CE) CE MARK REQUIRED FOR EUROPE (CE) CE MARK REQUIRED FOR EUROPE (SP) ANY SPECIAL FEATURE NOT COVERED IN THE MODEL NUMBER (SP) ANY SPECIAL FEATURE NOT COVERED IN THE MODEL NUMBER (X) NO SPECIAL FEATURES (X) NO SPECIAL FEATURES
CERTIFIED HAZARDOUS AREA CERTIFIED HAZARDOUS AREA SYSTEM RATINGS SYSTEM RATINGS
Style 3 and 7 Enclosures Only Style 3 and 7 Enclosures Only CSA/FM: Class I, Div. 1, GR. C,D; Class II, Div. 1, GR. E CSA/FM: Class I, Div. 1, GR. C,D; Class II, Div. 1, GR. E,F,G; Class III T6; Type 4X ,F,G; Class III T6; Type 4X Class I, Zone 1 AEx db IIB, T6 Gb, IP66 Class I, Zone 1 AEx db IIB, T6 Gb, IP66 Zone 21 AEx tb IIIC T80 Zone 21 AEx tb IIIC T80° °C Db; IP66 C Db; IP66 Ex db IIB T6; Ex tb IIIC T80 Ex db IIB T6; Ex tb IIIC T80° °C Gb; IP66 C Gb; IP66 ATEX/IECEx: II 2 G Ex db IIB T6 Gb; IP66 ATEX/IECEx: II 2 G Ex db IIB T6 Gb; IP66 II 2 D Ex tb IIIC T80 II 2 D Ex tb IIIC T80° °C Db; IP66 C Db; IP66 SEE TECHNICAL MANUAL OR LINK BELOW FOR INSTALLATION CONFIGURATIO SEE TECHNICAL MANUAL OR LINK BELOW FOR INSTALLATION CONFIGURATION N DETAILS. DETAILS.