product range
play

PRODUCT RANGE Cellswitch Infinity GSM Intercom Complex GSM - PowerPoint PPT Presentation

PRODUCT RANGE Cellswitch Infinity GSM Intercom Complex GSM Intercom Index GSM Intercom Mini GSM Intercom 2Button CELLSWITCH Infinity 1 year free airtime, data, smses and activated Vodacom and MTN simcards included. No


  1. PRODUCT RANGE • Cellswitch Infinity • GSM Intercom Complex • GSM Intercom Index • GSM Intercom Mini • GSM Intercom 2Button

  2. CELLSWITCH Infinity • 1 year free airtime, data, sms’es and activated Vodacom and MTN simcards included. • No activation and registration fees. Simply install the device and start using it. • Dual sim - Both sim cards are online at the same time to control separate outputs. • Unlimited alarm and control messages with our Instant Messenger App. • Free welcome sms’es to new users. • Energizer keypad data interface for remote programming, control and alarms.

  3. CELLSWITCH Infinity • A missed-call on sim 1 can control output 1 and a missed-call on sim 2 can control output 1 or 2. • 2 x Outputs (Control 2 separate gates). 4 x Inputs (Monitor various sensors). • 12/24V Battery voltage monitoring and notifications. • 10 000 programmable access control users. • Restricted time-based access control for domestic and gardening services. • Guest house feature with expiry date and access control notification. • Daily Peak-hour gate open/close timers with 'Public and School Holiday feature’. • Beam obstruction alarms and open/close notification from gate controller. • Low airtime, low battery and offline notifications. • Detailed access control reports from the ultra fast Accentronix Cloud 9.0 online platform. • Free welcome sms’es to new users – Message contains a web link that will give user-specific information with a list of all the devices they can use and how to use them, including time-based restrictions that may apply to the user. • Connects to ‘gate status’ output on gate controller for open/close monitoring. • Unlimited alarm and control messages with our Accentronix Instant Messenger app. • Alarms and events are sent by SMS, instant messenger and email. • Advanced Electric Fence monitoring and control by connecting Directly to the energizer Keypad Data Interface. • Monitor electric fence alarms, fence voltages, battery voltage, power-fail and tamper alarms on all popular energizers. • Energizer remote keypad commands by SMS. Send multiple commands in one SMS 012345*0# 261# *#

  4. CONNECTION TO GATE AND GARAGE FOR ACCESS CONTROL • Connect the gate controller’s status indicator directly to Input 1 or 2 to monitor gate open/close status. • Permanent beam-obstruction alarms can be done by using any of the 4 Inputs. • Connect the entrance or exit loop to Output 1 to force a car to be at the gate before allowing access. • Set the integrated output timers to trigger the exit loop for 120 seconds to allow for enough time for a visitor to reach the exit gate. • Use the output timers to automatically open the gate during peak hours but keep them closed during the weekend and public and school holidays. • Connect a Mag Lock directly to Output 1 ( n/c) and ( com) terminals of the integrated relay (2Amp @ 32Vac/dc) and set the integrated output delay timer to 10 seconds. • Connect Output 2 directly to the Pedestrian trigger . Output 2 is an ‘open collector’ output which means it gives 0V to what ever it is connected to while it is switched on. (max 1 Amp @ 32Vdc) . To drive heavier loads, connect the one end of the coil of an external (12/24Vdc coil) relay to 12/24Vdc and the other end of the external relay’s coil to Output 2. If output 2 is switched on, it will supply 0V to the relay and turn it on.

  5. QUICK CONNECTION TO ENERGIZER KEYPAD DATA INTERFACE Use Keypad Codes to communicate with your Energizer • Status: ? • ON/OFF: 1234# • ON: On • OFF: Off • Low Power: LP • High Power: HP • Connects and communicates directly with the Keypad Data Bus of most Send multiple keypad commands in energizer makes and models. Select the specific model in Advanced Settings. • Please note that some energizer models may display more or less info in the one sms by separating them with a status and alarm messages than others. space i.e. • Do NOT connect anything to Output 2 of the Infinity while in energizer mode. • A gate may be connected to Output 1 and be controlled by calling SIM 2 012345*0# 261# *# while the Infinity is in energizer mode. A call on SIM 1 will switch the energizer on or off. A keypad and Infinity can be Advanced options Only applicable to some energizers: Two energizers can be connected to each other in master/slave mode connected to an energizer and still be controlled separately with one Cellswitch Infinity. simultaneously. Zone 1 on: On1 Zone 1 off: Off1 Zone 2 on: On2 Zone 2 off: Off2

  6. ACCENTRONIX INSTANT MESSENGER FOR UNLIMITED ALARM AND CONTROL MESSAGES • Enjoy unlimited notification and control messages from and to your Cellswitch Infinity. • Install the Accentronix Messenger app from the Android Play Store on your smart phone free of charge. • If your phone temporarily loses its data connection you will receive messages by normal sms as a backup service. These messages are deducted from your subscription (60 sms’es per month). • Search for AccentroniX in the Play Store

  7. ADVANCED FEATURES • An energizer and gate can be connected simultaneously to an Infinity. The gate must be connected to output 1. A missed call on sim 1 will control the energizer and missed call on sim 2 will control the gate on output 1. • Long range remote feature : Two or more Infinities can communicate with each other via the internet (not by sms). This allows for unlimited communications. For example if input 1 on one Infinity is triggered it will control output 1 on another Infinity 1000 kilometers away. Multiple inputs can be routed to multiple remote outputs. • Mimic panel feature : Connect our 8in / 8out IO Expansion board to the Cellswitch Infinity to create a mimic panel that indicates alarm status of up to eight energizers. • Low power feature: (Only available on Infinity Eon devices) • Battery life of 10+ years depending on application. Water level control, Utility meter monitoring (water and electricity) and water trough monitoring on large farms. Device wakes up once a day to send in its status. Can also be set to wake up on input trigger alarms i.e. ‘Water Level Low’.

  8. GSM INTERCOM SYSTEMS

  9. GSM INTERCOM SYSTEMS • Calls directly to your cellphone or landline. • Includes activated and RICA registered Vodacom pre-paid sim card with R5.00 pre-loaded airtime. • Up to 10 000 programmable users. • 2 x Relay outputs (For main and pedestrian gates). • 2 x Digital inputs (To monitor power and gate status). • High quality stainless steel enclosure (GRADE 316). • Operating voltage 12/24Vdc 500mA. • Crystal clear sound. • Backlit keypad. • Cloud-based access control logs. • Restricted time-based access control. • Effortlessly manage a large number of access control users with our online Cloud 9.0 access control platform. • Manage one access control list for multiple linked devices. • If someone presses the programmed intercom button assigned to you, you will receive a call on you phone. Answer, and after you identified the person simply press ‘1’ on your phone to open Gate 1. Press ‘2’ on your phone to open Gate 2 (if applicable). Calls from the intercom to your number is charged to the sim in the intercom at standard network rates. Maximum call duration can also be set. Pressing button ‘9’ on your phone will also open Gate 1. • Free welcome sms’es to new users – The message contains a unique web link that will give user specific information with a list of all the devices they are linked to, intercom buttons assigned to them and how to use them.

  10. GSM Optional Connections: • Connect a 220Vac coil relay to the Power Fail input. INTERCOM • The Watchdog input is used for detecting if the gate is opened for longer than 3minutes. CONNECTION DIAGRAM Online Settings PCB • Output 1 and Output 2 are dry-contact (Normally Open) and (Common) relay outputs. • Power the Intercom with 12 or 24Vdc directly from the gate battery.

  11. • Restrict access control to specific days and times for Domestic and Gardening Service . RESTRICTED • Only allow access to main or pedestrian gates. • ACCESS Guesthouse feature – expire after allocated time and date. • Free welcome sms’es to new users – Message contains a web link that will give user CONTROL specific information with a list of all the devices they can use including applicable restrictions.

  12. ACCESS CONTROL • Detailed time-stamped access control logs can be accessed online or automatically emailed daily, weekly or monthly. LOGS

  13. • Detailed time-stamped access control and button press logs can be accessed online or automatically emailed daily, weekly or monthly. INTERCOM LOGS • ‘ Top 10 users ’ and ‘ total number of calls per user ’ statistics.

  14. REGISTERING A www.cellswitchportal.co.za DEVICE ON • Step 1: Make sure device is switched on with green led flashing slowly . • CLOUD 9.0 Step 2: Enter any name and the cell number of the device. • Step 3: Accept T&C. • .

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.

Recommend


More recommend