Product Range to be presented, Product Range to be presented, 1. - - PowerPoint PPT Presentation

product range to be presented product range to be
SMART_READER_LITE
LIVE PREVIEW

Product Range to be presented, Product Range to be presented, 1. - - PowerPoint PPT Presentation

Product Range to be presented, Product Range to be presented, 1. Static Blower 1. Static Blower Static Blower 1. 2. Roof Top 2. Roof Top Roof Top 2. 3. Mini-chiller 3. Mini Mini- -chiller chiller 3. 4. Fan Coil Units 4. Fan Coil


slide-1
SLIDE 1

Engineered for flexibility and performance. ™

  • 1. Static Blower
  • 2. Roof Top
  • 3. Mini-chiller
  • 4. Fan Coil Units
  • 5. Smart Manager
  • 6. Horizontal WSHP

1.

  • 1. Static Blower

Static Blower 2.

  • 2. Roof Top

Roof Top 3.

  • 3. Mini

Mini-

  • chiller

chiller 4.

  • 4. Fan Coil Units

Fan Coil Units 5.

  • 5. Smart Manager

Smart Manager 6.

  • 6. Horizontal WSHP

Horizontal WSHP

Product Range to be presented, Product Range to be presented,

slide-2
SLIDE 2

Engineered for flexibility and performance. ™

Ducted Split Blower, MDB Ducted Split Blower, MDB Ducted Split Blower, MDB

slide-3
SLIDE 3

Engineered for flexibility and performance. ™

MDB75/ 100 MDB75/ 100 MDB600/ 750 MDB600/ 750 MDB250 MDB250-

  • 500

500 MDB125 MDB125-

  • 150

150

Ducted Split System – I ndoor Units Ducted Split System Ducted Split System – – I ndoor Units I ndoor Units

slide-4
SLIDE 4

Engineered for flexibility and performance. ™

Ducted Split System – Outdoor Units Ducted Split System Ducted Split System – – Outdoor Units Outdoor Units

MMC 75/ 100/ 125B MMC 75/ 100/ 125B MMC75C MMC75C MMC75/ 100/ 125/ 150D MMC75/ 100/ 125/ 150D MMC200/ 250/ 300D MMC200/ 250/ 300D

slide-5
SLIDE 5

Engineered for flexibility and performance. ™

Ducted Split System – B/ D series Ducted Split System Ducted Split System – – B/ D series B/ D series

Std Air Throw Changeable?

SB75B/D Horizontal NO SB100B/D Horizontal NO SB125B Horizontal YES SB125D Horizontal NO SB150B Horizontal YES SB150D Horizontal NO SB200B Horizontal YES SB200D Vertical YES SB250-500B/D Vertical YES SB600-750B Vertical YES

Standard Air Throw Standard Air Throw

slide-6
SLIDE 6

Engineered for flexibility and performance. ™

Model Cooling / Heating Capacity (Btu/h) 50Hz 60Hz SB75B/BR 74,000 / 74,000 C/HP C/HP SB100B/BR 96,500 / 98,000 C/HP C/HP SB125C/CR 116,000 / 120,000 C/HP C/HP SB150B1 150000 / - C only C only SB150B2/BR2 148,000 / 148,000 C/HP C/HP SB200B2/BR2 193,120 / 197,600 C/HP C/HP SB250B2/BR2 232,000 / 240,000 C/HP C/HP SB300B3/BR3 289,500 / 296,400 C/HP C/HP SB350B3/BR3 330,800 / 335,500 C/HP C/HP SB400B4/BR4 386,000 / 395,200 C/HP C/HP SB450B4 450.000 / - C only

  • SB500B4/BR4

464,000 /480,000 C/HP C/HP SB600B4 600,000 / - C only

  • SB750B5

750,000 / - C only

  • Product Range (MDB

Product Range (MDB-

  • B Series)

B Series)

Ducted Split System – B/ D series Ducted Split System Ducted Split System – – B/ D series B/ D series

slide-7
SLIDE 7

Engineered for flexibility and performance. ™

Model Model Cooling / Heating Capacity (Btu/h) Cooling / Heating Capacity (Btu/h) 50Hz 50Hz 60Hz 60Hz SB 75 D/DR SB 75 D/DR 77,000 / 85,000 77,000 / 85,000 C/HP C/HP C/HP C/HP SB100 D/DR SB100 D/DR 96,000 / 106,000 96,000 / 106,000 C/HP C/HP C/HP C/HP SB125 D1/DR1 SB125 D1/DR1 116,000 / 130,000 116,000 / 130,000 C/HP C/HP C/HP C/HP SB125 D2/DR2 SB125 D2/DR2 110,000 / 117,000 110,000 / 117,000 C/HP C/HP

  • SB150 D1/DR1

SB150 D1/DR1 150,000 / 160,000 150,000 / 160,000 C/HP C/HP C/HP C/HP SB150 D2/DR2 SB150 D2/DR2 154,000 / 170,000 154,000 / 170,000 C/HP C/HP C/HP C/HP SB200 D2/DR2 SB200 D2/DR2 192,000 / 212,000 192,000 / 212,000 C/HP C/HP C/HP C/HP SB250 D2/DR2 SB250 D2/DR2 232,000 / 260,000 232,000 / 260,000 C/HP C/HP C/HP C/HP SB300 D2/DR2 SB300 D2/DR2 300,000 / 320,000 300,000 / 320,000 C/HP C/HP C/HP C/HP SB400 D4/DR4 SB400 D4/DR4 384,000 / 424,000 384,000 / 424,000 C/HP C/HP C/HP C/HP SB500 D4/DR4 SB500 D4/DR4 464,000 /520,000 464,000 /520,000 C/HP C/HP C/HP C/HP

Product Range (MDB Product Range (MDB-

  • D Series)

D Series)

Ducted Split System – B/ D series Ducted Split System Ducted Split System – – B/ D series B/ D series

slide-8
SLIDE 8

Engineered for flexibility and performance. ™

Model Cooling / Heating Capacity (Btu/h) 50Hz 60Hz SB 75 D/DR 73,000 / 81,000 C/HP N/A SB100 D/DR 91,000 / 109,000 C/HP N/A SB125 D/DR 108,000 / 124,000 C/HP N/A SB150 D1/DR1 145,000 / 150,000 C/HP N/A SB150 D2/DR2 146,000 / 162,000 C/HP N/A SB200 D2/DR2 182,000 / 218,000 C/HP N/A SB250 D2/DR2 216,000 / 248,000 C/HP N/A SB300 D2/DR2 290,000 / 300,000 C/HP N/A SB400 D4/DR4 364,000 / 436,000 C/HP N/A SB500 D4/DR4 432,000 / 496,000 C/HP N/A

Product Range (R407C MDB Product Range (R407C MDB-

  • D Series)

D Series)

Ducted Split System – B/ D series Ducted Split System Ducted Split System – – B/ D series B/ D series

slide-9
SLIDE 9

Engineered for flexibility and performance. ™

  • Scroll Compressor

Scroll Compressor

  • Horizontal and vertical throw

Horizontal and vertical throw

  • Belt driven (for SB125 and above)

Belt driven (for SB125 and above)

  • Sequential Controller for > 1 refrigerant

Sequential Controller for > 1 refrigerant circuit system. circuit system.

  • Wide range

Wide range

  • Phase Sequencing Protector

Phase Sequencing Protector

Ducted Split System – B/ D series Ducted Split System Ducted Split System – – B/ D series B/ D series

Product Features Product Features

  • Sq. Controller
  • Sq. Controller

SLM SLM

slide-10
SLIDE 10

Engineered for flexibility and performance. ™

07 07-

  • 28

28 30 30-

  • 61

61 75 75-

  • 150

150

  • R410A
  • R407C

Currently Available Outdoor Model (Btu/h)

R22 (MLC007C up to MMC300D2) R407C (M4LC007B up to M4MC150D) R410A (M5LC007C up to M5LC028C)

Summary for Outdoor Condensing Unit Summary for Outdoor Condensing Unit

Refrigerant Type and Range Refrigerant Type and Range 200 200-

  • 300

300

  • R22
slide-11
SLIDE 11

Engineered for flexibility and performance. ™

Air Cooled Rooftop Unit, MRT Air Cooled Rooftop Unit, MRT Air Cooled Rooftop Unit, MRT

slide-12
SLIDE 12

Engineered for flexibility and performance. ™

Air Cooled Rooftop Packaged Air Cooled Rooftop Packaged Air Cooled Rooftop Packaged

MRT 80/ 100/ 150/ 200 A MRT 80/ 100/ 150/ 200 A MRT 250/ 300 A MRT 250/ 300 A

slide-13
SLIDE 13

Engineered for flexibility and performance. ™

Model Capacity (Btu/h) 50Hz Cooling only Cooling / Heating RT060A/AR 59,000 56,000 / 68,000 C/HP RT080A/AR 75,000 78,600 / 80,000 C/HP RT100A/AR 100,000 105,000 /100,000 C/HP RT120A/AR 116,000 105,000 / 118,000 C/HP RT150A/AR 150,000 155,000 /150,000 C/HP RT200A/AR 200,000 208,000 /200,000 C/HP RT250A/AR 250,000 235,000 /252,000 C/HP RT300A/AR 300,000 290,000 /295,000 C/HP

Air Cooled Rooftop Packaged Air Cooled Rooftop Packaged Air Cooled Rooftop Packaged

Product Range (MRT Product Range (MRT-

  • A Series)

A Series)

slide-14
SLIDE 14

Engineered for flexibility and performance. ™

  • One complete set concept

One complete set concept

  • Air Discharged Flexibility

Air Discharged Flexibility

  • Belt driven, flexibility of air discharged

Belt driven, flexibility of air discharged

  • Sequential Controller (MRT150 & above)

Sequential Controller (MRT150 & above)

  • Scroll Compressor

Scroll Compressor

  • Phase Sequencing Protector

Phase Sequencing Protector

Product Features Product Features

Air Cooled Rooftop Packaged Air Cooled Rooftop Packaged Air Cooled Rooftop Packaged

slide-15
SLIDE 15

Engineered for flexibility and performance. ™

Container Loading (units) Container Loading (units) 60A 60A 80A 80A 100A 100A 120A 120A 150A 150A 200A 200A 250A 250A 300A 300A

  • 40

40’

’ Container (90

Container (90”

”x 90

x 90”

”x 470

x 470”

”)

) 28 28 16 16 16 16 16 16 6 6 6 6 4 4 4 4

  • 40

40’

’ Hi

Hi-

  • Cube (104

Cube (104”

”x 90

x 90”

”x 470

x 470”

”)

) 28 28 16 16 16 16 16 16 12 12 12 12 4 4 4 4

  • Flat Top Design, Stackable

Flat Top Design, Stackable

Product Features Product Features

Air Cooled Rooftop Packaged Air Cooled Rooftop Packaged Air Cooled Rooftop Packaged

slide-16
SLIDE 16

Engineered for flexibility and performance. ™

McQuay Chilled Water System & Product Range McQuay Chilled Water System McQuay Chilled Water System & Product Range & Product Range

slide-17
SLIDE 17

Engineered for flexibility and performance. ™

McQuay Offers: McQuay Offers:

Chilled Water System and Products Chilled Water System and Products Chilled Water System and Products

  • 1. Air Cooled Mini Chiller
  • 1. Air Cooled Mini Chiller
  • 2. Various choices of Fan Coil Units
  • 2. Various choices of Fan Coil Units
  • 3. Chilled Water I ntelligent Controller
  • 3. Chilled Water I ntelligent Controller –

– Smart Manager Smart Manager

  • 4. HydroPro Selection software
  • 4. HydroPro Selection software
slide-18
SLIDE 18

Engineered for flexibility and performance. ™

20 40 60 80 100 120 140 160 R22 5.9 11.7 17.6 29.3 35.2 41.0 R407C R410A 23.5 46.9 Btu/hr x 103 kW

McQuay Air Cooled Chiller Product Range McQuay Air Cooled Chiller Product Range

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

slide-19
SLIDE 19

Engineered for flexibility and performance. ™

M(4)AC 80/ 100/ 120/ 150 C M(4)AC 80/ 100/ 120/ 150 C

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

M(4)AC 20/ 25/ 30C M(4)AC 20/ 25/ 30C M(4)AC 40/ 50/ 60 C M(4)AC 40/ 50/ 60 C

slide-20
SLIDE 20

Engineered for flexibility and performance. ™

Model Cooling Only Cooling/ Heating 50Hz AC020C/CR 18,000 18,000/22,000 C/HP AC025C/CR 23,500 23,000/25,000 C/HP AC030C/CR 27,500 27,500/31,500 C/HP AC040C/CR 40,000 40,000/43,000 C/HP AC050C/CR 50,000 46,000/52,000 C/HP AC060C/CR 53,000 53,000/59,000 C/HP AC080C/CR 78,000 77,000/90,000 C/HP AC100C/CR 93,000 94,000/110,000 C/HP AC120C/CR 116,000 113,000/120,000 C/HP AC150C/CR 138,000 138,000/132,000 C/HP

Product Range (MAC Product Range (MAC-

  • C Series)

C Series)

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

slide-21
SLIDE 21

Engineered for flexibility and performance. ™

Model Height (mm) Length (mm) Depth (mm) MAC20-30 C 800 1160 460 MAC40-60 C 1410 1160 460 MAC80-100 C 1452 1732 1032 MAC120-150 C 1452 2032 1282

Product Dimension Product Dimension

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

slide-22
SLIDE 22

Engineered for flexibility and performance. ™

MAC/ M4AC 20/ 25/ 30 C/ CR MAC/ M4AC 20/ 25/ 30 C/ CR

  • Approx. Capacity: 20,000
  • Approx. Capacity: 20,000-
  • 30,000 Btu/ hr

30,000 Btu/ hr Refrigerant Circuit: Single Refrigerant Circuit: Single

MAC/ M4AC 40/ 50/ 60 C/ CR MAC/ M4AC 40/ 50/ 60 C/ CR

  • Approx. Capacity: 40,000
  • Approx. Capacity: 40,000-
  • 60,000 Btu/ hr

60,000 Btu/ hr Refrigerant Circuit: Single Refrigerant Circuit: Single

MAC/ M4AC 80/ 100/ 120/ 150 C/ CR

  • Approx. Capacity: 80,000-150,000 Btu/ hr

Refrigerant Circuit: Double

Air Cooled Mini Chiller Product Range Air Cooled Mini Chiller Product Range Air Cooled Mini Chiller Product Range

Product Range (MAC & M4AC) Product Range (MAC & M4AC)

slide-23
SLIDE 23

Engineered for flexibility and performance. ™

  • 1. Compactness
  • 1. Compactness
  • is designed with the consideration;

is designed with the consideration;

  • Less Foot Print Occupied

Less Foot Print Occupied

  • Less Space Required

Less Space Required

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

Product Features Product Features

slide-24
SLIDE 24

Engineered for flexibility and performance. ™

  • 2. Scroll Compressor
  • 2. Scroll Compressor
  • To offer quieter & reliable performance (except size 20)

To offer quieter & reliable performance (except size 20)

  • For 3 phase models, phase protector is provided.

For 3 phase models, phase protector is provided.

  • 3. Brazed Plate Heat Exchanger
  • 3. Brazed Plate Heat Exchanger
  • Made of AI SI 316 Stainless Steel

Made of AI SI 316 Stainless Steel

  • High heat exchange efficiency

High heat exchange efficiency

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

Product Features Product Features

slide-25
SLIDE 25

Engineered for flexibility and performance. ™

  • 4. Microprocessor Control
  • 4. Microprocessor Control
  • Equipped with microprocessor controller

Equipped with microprocessor controller

  • Precise operation and temperature control

Precise operation and temperature control

  • 5. Partial Loading
  • 5. Partial Loading
  • For MAC/ M4AC 80

For MAC/ M4AC 80-

  • 150 C/ CR can perform in 2 stages loading

150 C/ CR can perform in 2 stages loading capability of compressor at 50% capability of compressor at 50% -

  • 100%

100%

  • I mprove reliability & energy efficiency

I mprove reliability & energy efficiency

  • Useful in the low load condition

Useful in the low load condition

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

Product Features Product Features

100 50

  • Comp. Loading %

Step Capacity

slide-26
SLIDE 26

Engineered for flexibility and performance. ™

  • 6. Antifreeze Protection
  • 6. Antifreeze Protection
  • Built

Built-

  • in Heater I n BPHE

in Heater I n BPHE

  • Antifreeze sensors

Antifreeze sensors

  • Water Pressure Differential Switch

Water Pressure Differential Switch

  • 7. Sequencing Control
  • 7. Sequencing Control
  • Compressor cut in & cut out depending on their accumulative

Compressor cut in & cut out depending on their accumulative

  • perating time
  • perating time

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

Product Features Product Features

slide-27
SLIDE 27

Engineered for flexibility and performance. ™

  • 8. Safety Protection
  • 8. Safety Protection
  • High & Low Pressure Switches

High & Low Pressure Switches

  • Water Pressure Differential Switches

Water Pressure Differential Switches

  • Discharge Temperature Sensor

Discharge Temperature Sensor

  • Compressor Pump & Fan Motor Overload Protector

Compressor Pump & Fan Motor Overload Protector

  • Anti Freeze Protection Sensor

Anti Freeze Protection Sensor

  • Over Pressure Relief Valve

Over Pressure Relief Valve

  • Antifreeze heater on BPHE

Antifreeze heater on BPHE

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

Product Features Product Features

slide-28
SLIDE 28

Engineered for flexibility and performance. ™

  • 9. Modular I nstallation
  • 9. Modular I nstallation
  • System flexibility for future

System flexibility for future Expansion Expansion

  • 50 units of chiller can be

50 units of chiller can be linked together linked together

Water In Water Out Up to 50 Chillers Chiller Bus

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

Product Features Product Features

slide-29
SLIDE 29

Engineered for flexibility and performance. ™

  • 10. Chiller Control Panel
  • 10. Chiller Control Panel
  • Allows user to have customized control of each connected unit

Allows user to have customized control of each connected unit

  • User Friendly, versatile control features

User Friendly, versatile control features

Operation Menu Operation Menu Setting Menu Setting Menu Timer Menu Timer Menu Alarm Menu Alarm Menu Display Menu Display Menu

  • Main Menu includes;

Main Menu includes;

  • Whole system configuration

Whole system configuration

Air Cooled Mini Chiller Air Cooled Mini Chiller Air Cooled Mini Chiller

Product Features Product Features

slide-30
SLIDE 30

Engineered for flexibility and performance. ™

McQuay Offers: McQuay Offers:

Chilled Water System and Products Chilled Water System and Products Chilled Water System and Products

  • 1. Air Cooled Mini Chiller
  • 1. Air Cooled Mini Chiller
  • 2. Various choices of Fan Coil Units
  • 2. Various choices of Fan Coil Units
  • 3. Chilled Water I ntelligent Controller
  • 3. Chilled Water I ntelligent Controller –

– Smart Manager Smart Manager

  • 4. HydroPro Selection software
  • 4. HydroPro Selection software
slide-31
SLIDE 31

Engineered for flexibility and performance. ™

Wall Mounted (WM-FW) Wall Mounted (WM-FW)

Capacity : 1.41 – 6.15 kW 4,800 – 21,000 Btu/hr Model : MWM 05/07/10/15/20/25 FW 7.03 kW 24,000 Btu/hr MWM 301W * 3 Stage Filter (Except MWM301W) * Automatic Air Swing (Up & Down) * NI M-able * Self Diagnosis

Standard

Chilled Water Fan Coil Units Chilled Water Fan Coil Units Chilled Water Fan Coil Units

Optional

slide-32
SLIDE 32

Engineered for flexibility and performance. ™

Ceiling Cassette (MCK-AW/ BW/ CW) Ceiling Cassette (MCK-AW/ BW/ CW)

Capacity : 7.03 – 11.72 kW 24,000 – 40,000 Btu/hr Model : MCK 20/25/30/40/50 AW

* Built- I n High Head Drain Pump * Stylish and Slim Panel * Self Diagnosis Features * NI M-able

3.66 – 6.74 kW 12,500 – 23,000 Btu/hr MCK 15/20/25 BW 2.52 – 4.83 kW 8,600 – 16,500 Btu/hr MCK 10/15/20 CW

* Choice of 2 pipes and 4 pipes * Wide Range of Offerings * 4 Way Air Discharge & Air Swing

Standard Optional

Chilled Water Fan Coil Units Chilled Water Fan Coil Units Chilled Water Fan Coil Units

slide-33
SLIDE 33

Engineered for flexibility and performance. ™

Ceiling Convertible (MCM-DW) Ceiling Convertible (MCM-DW)

Capacity : 5.86 – 13.77 kW 20,000 – 47,000 Btu/hr Model : MCM 20/25/30/40/50 DW * Ceiling & Floor I nstallation Option * Automatic Air Swing * Self Diagnosis * NI M-able * Two Way Air Discharge

Standard Optional

Chilled Water Fan Coil Units Chilled Water Fan Coil Units Chilled Water Fan Coil Units

slide-34
SLIDE 34

Engineered for flexibility and performance. ™

Ceiling Concealed (MCC-CW) Ceiling Concealed (MCC-CW)

Capacity : 2.93 – 15.83 kW 10,000 – 54,000 Btu/hr Model : MCC 10/15/20/25/28/30/38/40/50/60 CW * Microprocessor Controlled * Self Diagnosis * NI M-able * Double Protection Drainage System * Duct Accessories Provided (Optional)

Chilled Water Fan Coil Units Chilled Water Fan Coil Units Chilled Water Fan Coil Units

Standard

slide-35
SLIDE 35

Engineered for flexibility and performance. ™

Ducted Blower (MDB) Ducted Blower (MDB)

Capacity : 22.27 – 47.77 kW 76,000 – 163,000 Btu/hr Model : MDB 75/100/125/150 BW * Strong & Robust Structure * High CFM * Self Diagnosis * NI M-able

Chilled Water Fan Coil Units Chilled Water Fan Coil Units Chilled Water Fan Coil Units

slide-36
SLIDE 36

Engineered for flexibility and performance. ™

Ceiling Concealed (MCW) Ceiling Concealed (MCW)

Capacity : 2.26 – 11.9 kW 7,710 – 40,650 Btu/hr Model : MCW 200/300/400/600/800/1000/1200 C * Left and right hand pipe handling * ESP of: 30, 50, 80 pascal * Choice of 2 pipes, 4 pipes * Simple design * Extended drain pan

Chilled Water Fan Coil Units Chilled Water Fan Coil Units Chilled Water Fan Coil Units

* NI M-able

slide-37
SLIDE 37

Engineered for flexibility and performance. ™

McQuay Offers: McQuay Offers:

Chilled Water System and Products Chilled Water System and Products Chilled Water System and Products

  • 1. Air Cooled Mini Chiller
  • 1. Air Cooled Mini Chiller
  • 2. Various choices of Fan Coil Units
  • 2. Various choices of Fan Coil Units
  • 3. Chilled Water I ntelligent Controller
  • 3. Chilled Water I ntelligent Controller –

– Smart Manager Smart Manager

  • 4. HydroPro Selection software
  • 4. HydroPro Selection software
slide-38
SLIDE 38

Engineered for flexibility and performance. ™

A Chilled Water System I ntelligent Controller A Chilled Water System I ntelligent Controller A Chilled Water System I ntelligent Controller Smart Manager Smart Manager Smart Manager

slide-39
SLIDE 39

Engineered for flexibility and performance. ™

Support up to 50 Chillers in one chiller BUS and up to 120 Support up to 50 Chillers in one chiller BUS and up to 120 FCUs FCUs in in

  • ne NI M BUS.
  • ne NI M BUS.

Networking Networking

Smart Manager Smart Manager Smart Manager

slide-40
SLIDE 40

Engineered for flexibility and performance. ™

Chiller Chiller – – One set of 7 days programmable operating schedules One set of 7 days programmable operating schedules (2 ON/ OFF timers per day) (2 ON/ OFF timers per day) FCUs FCUs – – Five set of 7 days programmable operating schedules. Five set of 7 days programmable operating schedules. (2 ON/ OFF timers per day) (2 ON/ OFF timers per day)

Programmable Energy Saving Timer Programmable Energy Saving Timer

Smart Manager Smart Manager Smart Manager

slide-41
SLIDE 41

Engineered for flexibility and performance. ™

  • 10

10 holidays with duration of

holidays with duration of 99

99 days each can be set. All

days each can be set. All FCUs FCUs & Chiller will be turned OFF during the holiday period. & Chiller will be turned OFF during the holiday period.

  • Timer Schedules are disabled during holiday period.

Timer Schedules are disabled during holiday period.

Holiday Setting (FCU) Holiday Setting (FCU)

Smart Manager Smart Manager Smart Manager

slide-42
SLIDE 42

Engineered for flexibility and performance. ™

Whenever Smart Manager receives a new alarm from Chiller or Whenever Smart Manager receives a new alarm from Chiller or FCUs FCUs, an alarm message will pop up on the LCD screen; shows , an alarm message will pop up on the LCD screen; shows type of alarm, alarm occurred time, date and unit. type of alarm, alarm occurred time, date and unit. Backlight blinking and alarms buzzer produces beeping sound (if Backlight blinking and alarms buzzer produces beeping sound (if it it’ ’s set s set ‘ ‘ON ON’ ’) )

Display up to 46 types of Chiller Fault/ Alarm and 6 Display up to 46 types of Chiller Fault/ Alarm and 6 types of types of FCUs FCUs Fault/ Alarm Fault/ Alarm

Smart Manager Smart Manager Smart Manager

New Alarm 1 Comp 1 Overload 06/04/05 12:00 am [Ch 3]

slide-43
SLIDE 43

Engineered for flexibility and performance. ™

Memory Backup, Alarm Memory for Chiller & Memory Backup, Alarm Memory for Chiller & FCUs FCUs Real Time Clock (RTC) Settings Real Time Clock (RTC) Settings

  • Allows user to set the time and date

Allows user to set the time and date

Password Protection Password Protection

  • For advance parameter settings (Chiller)

For advance parameter settings (Chiller)

  • Setting Protection

Setting Protection

Smart Manager Smart Manager Smart Manager

slide-44
SLIDE 44

Engineered for flexibility and performance. ™

Defrost & Discharge Sensor Temp Display (Chiller) Defrost & Discharge Sensor Temp Display (Chiller) Accumulative Compressor Run Time Accumulative Compressor Run Time

  • Servicing purpose

Servicing purpose

Smart Manager Smart Manager Smart Manager

Defrost Sensor Comp 1 : 12.8 °C Discharge Sensor Comp 1 : 36.5 °C

slide-45
SLIDE 45

Engineered for flexibility and performance. ™

Priority Setting FCU System Configuration FCU controls the running mode of Chiller

  • No FCUs ON – Chiller Turns OFF automatically
  • One FCU ON – Chiller Turns ON automatically

Switching Chiller mode (Cooling/Heating) based on threshold value. Chiller Chiller controls the running mode of FCU

  • No Chiller ON – FCU Turns OFF automatically
  • One Chiller ON – FCU can be turned ON

Priority Setting Priority Setting

Smart Manager Smart Manager Smart Manager

slide-46
SLIDE 46

Engineered for flexibility and performance. ™

  • Priority Must set to FCU

Priority Must set to FCU

Example: Example:

  • 1. Chiller Mode = Heat
  • 1. Chiller Mode = Heat

2.

  • 2. Cool Threshold Setting

Cool Threshold Setting ≤ ≤ 60% , Heat Threshold 60% , Heat Threshold ≤ ≤ 50% 50% 3.

  • 3. Chiller will only turn to COOL mode if

Chiller will only turn to COOL mode if

  • At least 60% of the operating

At least 60% of the operating FCUs FCUs require Cool Mode require Cool Mode

Threshold Value Setting Threshold Value Setting

Smart Manager Smart Manager Smart Manager

slide-47
SLIDE 47

Engineered for flexibility and performance. ™

FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU

COOL COOL COOL COOL COOL COOL COOL COOL COOL COOL COOL COOL HEAT HEAT HEAT HEAT HEAT HEAT HEAT HEAT

CHILLER CHILLER CHILLER

FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU FCU

OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF

Chiller will operate in the Cool Mode Chiller will operate in the Cool Mode

Example Example

Smart Manager Smart Manager Smart Manager

slide-48
SLIDE 48

Engineered for flexibility and performance. ™

McQuay Offers: McQuay Offers:

Chilled Water System and Products Chilled Water System and Products Chilled Water System and Products

  • 1. Air Cooled Mini Chiller
  • 1. Air Cooled Mini Chiller
  • 2. Various choices of Fan Coil Units
  • 2. Various choices of Fan Coil Units
  • 3. Chilled Water I ntelligent Controller
  • 3. Chilled Water I ntelligent Controller –

– Smart Manager Smart Manager

  • 4. HydroPro Selection software
  • 4. HydroPro Selection software
slide-49
SLIDE 49

Engineered for flexibility and performance. ™

HydroPro Selection Software HydroPro Selection Software HydroPro Selection Software

  • Equipment selection software

Equipment selection software

  • Piping Selection software

Piping Selection software

  • All new product database can be downloaded from e

All new product database can be downloaded from e-

  • distributor

distributor

slide-50
SLIDE 50

Engineered for flexibility and performance. ™

Horizontal Water Source Heat Pump MWH-B/ BR Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump MWH MWH-

  • B/ BR

B/ BR

slide-51
SLIDE 51

Engineered for flexibility and performance. ™

Product I ntroduction Product I ntroduction

  • Water Cooled Product

Water Cooled Product

  • Packaged types

Packaged types

  • Capacity: 3.4kW

Capacity: 3.4kW – – 23.0kW 23.0kW

  • 11,600 Btu/ hr to ~ 78,480 Btu/ hr

11,600 Btu/ hr to ~ 78,480 Btu/ hr

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

MODEL

MWH011BR MWH012BR MWH015BR MWH020BR MWH025BR

NOMINAL COOLING CAPACITY kW 3.4 3.5 4.2 5.7 7.6 Btu/h 11600 12000 14400 19500 26000 NOMINAL HEATING CAPACITY kW 3.8 3.7 4.3 5 8.4 Btu/h 13000 12700 14800 17000 28800 MODEL

MWH030BR MWH040BR MWH050BR MWH060BR MWH070BR

NOMINAL COOLING CAPACITY kW 9.0 13.0 15.0 19.0 23.0 Btu/h 30710 44360 51510 64820 78480 NOMINAL HEATING CAPACITY kW 9.5 15.5 17.0 20.5 23.0 Btu/h 32410 52890 58000 69950 78480

slide-52
SLIDE 52

Engineered for flexibility and performance. ™

MWH11/ 12/ 15/ 20/ 25/ 30/ 40/ 50/ 60/ 70 B/ BR MWH11/ 12/ 15/ 20/ 25/ 30/ 40/ 50/ 60/ 70 B/ BR MWH11/ 12/ 15/ 20/ 25/ 30/ 40/ 50/ 60/ 70 B/ BR

10 20 30 40 50 60 70 Btu/hr x 103 80 2.93 5.86 8.79 14.65 17.59 20.52 11.72 23.45 kW

Product Name Product Name

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-53
SLIDE 53

Engineered for flexibility and performance. ™

  • Multi space commercial

Multi space commercial Buildings Buildings

  • Piping connecting all of the

Piping connecting all of the WSHP to a closed water loop. WSHP to a closed water loop.

  • The system includes, cooling

The system includes, cooling tower/ dry cooler, boiler, piping, tower/ dry cooler, boiler, piping, pumps, expansion tank and related pumps, expansion tank and related accessories. accessories.

Product Application Product Application

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-54
SLIDE 54

Engineered for flexibility and performance. ™

  • 1. Low Height Profile
  • 1. Low Height Profile
  • 1. Low Height Profile
  • MWH-11 B/ BR using Horizontal

Compressor

  • Flexibility in I nstallation

WH11 B/ BR WH11 B/ BR

250 mm!! 250 mm!!

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-55
SLIDE 55

Engineered for flexibility and performance. ™

WH WH-

  • B/BR

B/BR Height (mm) Height (mm) 11 11 250 250 12 12 325 325 15 15 337 337 20 20 353 353 25 25 340 340 30 30 370 370 40 40 440 440 50 50 440 440 60 60 475 475 70 70 500 500

  • 2. Height of the MWH-B/ BR
  • 2. Height of the MWH
  • 2. Height of the MWH-
  • B/ BR

B/ BR 250 mm to 500 mm 250 mm to 500 mm 250 mm to 500 mm

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-56
SLIDE 56

Engineered for flexibility and performance. ™

  • 3. Developed on Less Vibration Design
  • 3. Developed on Less Vibration Design
  • 3. Developed on Less Vibration Design
  • Double I solation Panel

Upper Panel Lower Panel Compressor Grommet

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-57
SLIDE 57

Engineered for flexibility and performance. ™

  • 4. No Outdoor Fan is Required
  • 4. No Outdoor Fan is Required
  • 4. No Outdoor Fan is Required
  • Extremely quiet design

Extremely quiet design

  • No visible outdoor unit

No visible outdoor unit

  • Avoid the air well effect

Avoid the air well effect Example

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-58
SLIDE 58

Engineered for flexibility and performance. ™ Hot Air Hot Air Building A Building A Building B Building B Building C Building C Building D Building D Building E Building E Building F Building F

I mproper arrangement of

  • utdoor unit (air cooled) in the

building will trap the hot air which will affect the performance of the air conditioner. I mproper arrangement of I mproper arrangement of

  • utdoor unit (air cooled) in the
  • utdoor unit (air cooled) in the

building will trap the hot air building will trap the hot air which will affect the which will affect the performance of the air performance of the air conditioner. conditioner.

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-59
SLIDE 59

Engineered for flexibility and performance. ™

  • 5. High Heat Exchange Efficiency
  • 5. High Heat Exchange Efficiency
  • 5. High Heat Exchange Efficiency
  • Tube in Tube Heat Exchanger

Tube in Tube Heat Exchanger

  • High Energy Efficiency Rating (EER) with

High Energy Efficiency Rating (EER) with

  • MWH11

MWH11-

  • WH30: Panasonic Rotary Compressor

WH30: Panasonic Rotary Compressor

  • MWH30

MWH30-

  • WH70: Mitsubishi Rotary Compressor

WH70: Mitsubishi Rotary Compressor

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-60
SLIDE 60

Engineered for flexibility and performance. ™

High COP and EER High COP and EER High COP and EER

1 2 3 4 5 6 W H 1 1 W H 1 2 W H 1 5 W H 2 W H 2 5 W H 3 W H 4 W H 5 W H 6 W H 7 0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 W H 1 1 W H 1 2 W H 1 5 W H 2 W H 2 5 W H 3 W H 4 W H 5 W H 6 W H 7

Heating COP Heating COP vs vs Models Models Cooling EER Cooling EER vs vs Models Models Range: 3.3 Range: 3.3 – – 5.4 5.4 Range: 12.6 Range: 12.6 – – 16.3 16.3

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-61
SLIDE 61

Engineered for flexibility and performance. ™

  • 6. Application Flexibility
  • 6. Application Flexibility
  • 6. Application Flexibility
  • Wide Operating Range of Temperature

Wide Operating Range of Temperature 13 13° °C C ≤ ≤ EWT EWT ≤ ≤ 45 45° °C C 10 10° °C C ≤ ≤ EWT EWT ≤ ≤ 32 32° °C C Cooling Cycle EWT Range Cooling Cycle EWT Range Heating Cycle EWT Range Heating Cycle EWT Range

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-62
SLIDE 62

Engineered for flexibility and performance. ™

  • 7. Protection Features
  • 7. Protection Features
  • 7. Protection Features

HP & LP Switches HP & LP Switches

  • Compressor Overload Protection

Compressor Overload Protection Water Outlet Sensor Water Outlet Sensor

  • Monitoring the Leaving Water Temperature

Monitoring the Leaving Water Temperature Suction Sensor Suction Sensor

  • Compressor will cut out if the suction Temperature is less

Compressor will cut out if the suction Temperature is less than than -

  • 6

6° °C C

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-63
SLIDE 63

Engineered for flexibility and performance. ™

  • 8. Part Loading Capability (MWH25-MWH70)
  • 8. Part Loading Capability (MWH25
  • 8. Part Loading Capability (MWH25-
  • MWH70)

MWH70)

  • 2 stage loading capacity at 50%

2 stage loading capacity at 50% -

  • 100%

100%

  • Less Noise during low load condition

Less Noise during low load condition

  • Energy Saving

Energy Saving

100 50

  • Comp. Loading %

Step Capacity

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump

slide-64
SLIDE 64

Engineered for flexibility and performance. ™

  • 8. Sequencing Control of the Compressor

(MWH25-MWH70)

  • 8. Sequencing Control of the Compressor
  • 8. Sequencing Control of the Compressor

(MWH25 (MWH25-

  • MWH70)

MWH70)

  • Accumulative compressor operating time

Accumulative compressor operating time can be monitored can be monitored

  • Even loading of the compressor

Even loading of the compressor

  • I mprove compressor reliability

I mprove compressor reliability

COMP1 COMP1 COMP2 COMP2

Product Features Product Features

Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump Horizontal Water Source Heat Pump