Kon ar Power Transformers Ltd. Joint Venture of Siemens and Kon - - PowerPoint PPT Presentation

kon ar power transformers ltd
SMART_READER_LITE
LIVE PREVIEW

Kon ar Power Transformers Ltd. Joint Venture of Siemens and Kon - - PowerPoint PPT Presentation

Kon ar Power Transformers Ltd. Joint Venture of Siemens and Kon ar TP comprising all products of HV substations including their electrical integration to systems Gas insulated substation Air insulated substation Power quality


slide-1
SLIDE 1

Končar – Power Transformers Ltd.

Joint Venture of Siemens and Končar

slide-2
SLIDE 2

June, 2019 Page 2 Končar – Power Transformers Ltd.

TP comprising all products of HV substations including their electrical integration to systems

Transformer Arrester Circuit Breaker Current Transformer Circuit Breaker Disconnector Disconnector Coils Bushing GIS

Gas insulated substation

Reactors

Power quality

Phase Shifter Line Traps Insulators VoltageTransformer

Air insulated substation System Product Sensors and connectivity; control, protection and automation; medium voltage; parameterization, system engineering; HV connection between AIS/GIS and transformers

slide-3
SLIDE 3

Page 3 June, 2019 Končar – Power Transformers Ltd.

Manufacturing Places Siemens TP

Toronto, CA Jackson, US Guanajuato, MX Querétaro, MX Cairo Mont., IT Troisdorf, DE Berlin, DE Dresden, DE Bamberg, DE Nuremberg, DE Leonding, AT Linz, AT Weiz, AT Voronesh, RU Shenyang, CN Jinan, CN Trento, IT Jundiaí, BR Zagreb, HR Kalwa, IN Aurangabad, IN Hyderabad, IN Guangzhou, CN Pravets, BG Wuxi, CN Shanghai, CN Hangzhou, CN Wuhan, CN Saint-Louis, FR Jakarta, ID (in set up)

Ø Clear global product responsibility in Lead Factories for highest performance of entire factory network

Factory Network

Lead Lead Lead

Air Insulated Switchgear Gas Insulated Switchgear Power Transformers

Guangzhou, CN Wuxi, CN Shanghai, CN Hangzhou, CN

slide-4
SLIDE 4

June, 2019 Page 4 Končar – Power Transformers Ltd.

Siemens Transformers Merged strengths - our history

slide-5
SLIDE 5

June, 2019 Page 5 Končar – Power Transformers Ltd.

1921 1946 1991 1995

Ø Production and repair of rotating machines and transformers Ø First assinchrone machine with the winding from enamel copper wire Ø 1947 – 1960 Transformers voltage class up to 123kV Ø From 1962 Transformers voltage class up to 245kV Ø 1965 New factory production capacity 3500 MVA/y Ø From 1970 Transformers voltage clas up to 420 kV, ratings up to 725MVA Ø 1991 Independent Končar Power Transformers Ltd. (KPT) Ø 1995 Joint Venture of Siemens and Končar Ø Certificates ISO 9001, ISO 14001, OHSAS 18001, ISO/IEC 27001:2005 Ø Transformers voltage class up to 550 kV, ratings up to 1000 MVA Ø HVDC transformers Ø SVC transformers

KPT Company History

slide-6
SLIDE 6

June, 2019 Page 6 Končar – Power Transformers Ltd.

Manufacturing Program

Generator transformers Ø Up to 1000 MVA Ø Up to 550 kV

Ø Furnace and rectifier

Ø For railways Large transmission transformers and autotransformers Ø Up to 1000 MVA Ø Up to 550 kV Ø Up to 550 kV Ø Customer support Ø Diagnostic and maintenance HVDC transformers Special transformers Transformer life management

slide-7
SLIDE 7

Page 7 June, 2019 Končar – Power Transformers Ltd.

Production 1949 – 12/2018

Highest operation voltage (kV) Units Total power (MVA) Export (MVA) 72,5 534 17.750,90 17.725,90 123 904 35.110,15 13.497,65 170 409 29.293,25 29.293,25 245 487 82.263,23 69.602,23 420 596 159.709,90 137.117,90 550 76 19.385,32 19.385,32 Total 3.006 343.512,75 286.622,25 Average transformer power / year: 114,28 MVA Rated power (average) 2009 – 2018 182,66 MVA Rated power (average) 2017 – 2018 207,22 MVA Export 2009 – 2018 97,74% Total export 1949 – 2018 83,44%

slide-8
SLIDE 8

Page 8 June, 2019 Končar – Power Transformers Ltd.

Export

Total of 90 countries Export in 2009 – 12/2018 = 97.74%

slide-9
SLIDE 9

June, 2019 Page 9 Končar – Power Transformers Ltd.

Siemens KPT Transformer Factory

Today: Ø Total Area: 48.467 m² Ø Under the roof: 25.125 m²

slide-10
SLIDE 10

Page 10 June, 2019 Končar – Power Transformers Ltd.

Ø Total working area: 1632m² Ø Air conditioned Ø Cuttting to the lenght, core sheet up to 1000 mm width Ø Cutting capacity: 5500 t/y

Core-Sheet Cutting & Stacking Area

slide-11
SLIDE 11

Page 11 June, 2019 Končar – Power Transformers Ltd.

Total working area:

Ø 1800 m²

Winding machines:

Ø Vertical: 4 units Ø Horizontal: 7 units

Overpressure controlled Air conditioned

Winding Workshop

slide-12
SLIDE 12

Page 12 June, 2019 Končar – Power Transformers Ltd.

Total area of 4661 m² Air conditioned Main equipment:

Ø Crane – capacity 150 t, 3 units Ø Crane – capacity 400 t, 1 unit Ø Other cranes: 3 – 32 t, 7 units Ø Movable scafold 5 units Ø Vapour phase drying chamber – 2 units Ø Air cushions, capacity up to 500 t

Assembly Workshop

slide-13
SLIDE 13

Page 13 June, 2019 Končar – Power Transformers Ltd.

Desert Climate & Online Air Quality Monitoring

Desert Climate

Preparation of active part before tanking Performed in controlled environment: Ø Humidity below 10% Ø Temperature 20 – 30 ˚C

Online Air Quality Monitoring

Ø Continuous online measurement of: air pressure, temperature, humidity, low power gas concentration and dust particles density

slide-14
SLIDE 14

Page 14 June, 2019 Končar – Power Transformers Ltd.

The building is 100% Electrostatically (Faraday cage) & noise shielded

Test Laboratory

Testing area Ø 1050 m²

slide-15
SLIDE 15

Page 15 June, 2019 Končar – Power Transformers Ltd.

Test Laboratory

Dimensions of testing area: Ø Surface 30 m × 35 m Ø Height 25 m

slide-16
SLIDE 16

Page 16 June, 2019 Končar – Power Transformers Ltd.

ISO/IEC 27001:2013

Integrated Management System

ISO 9001:2008 ISO 14001:2004 BS OHSAS 18001:2007

slide-17
SLIDE 17

Page 17 June, 2019 Končar – Power Transformers Ltd.

Transport

slide-18
SLIDE 18

Page 18 June, 2019 Končar – Power Transformers Ltd.

On time delivery!

Transport

slide-19
SLIDE 19