Jim’s Insulation Services Insulbloc
High Performance Wall and Closed Cavity Thermal Insulation for existing homes and other buildings
28/05/2013
Insulbloc Presentation (2)
1
Jims Insulation Services Insulbloc High Performance Wall and Closed - - PowerPoint PPT Presentation
Jims Insulation Services Insulbloc High Performance Wall and Closed Cavity Thermal Insulation for existing homes and other buildings 1 Insulbloc Presentation (2) 28/05/2013 Jims Insulation Services Insulbloc High Performance Wall and
28/05/2013
Insulbloc Presentation (2)
1
28/05/2013
Insulbloc Presentation (2)
2
28/05/2013
Insulbloc Presentation (2)
3
Insulbloc Presentation (2)
28/05/2013
4
Insulbloc Features & Benefits
(if you already have the correct roof and underfloor insulation for your climate zone)
Insulbloc Presentation (2)
28/05/2013
5
Insulbloc Features & Benefits
guaranteeing complete coverage. A brick may need to be removed and replaced under wide windows that don’t go to floor level. Insulbloc’s down the wall installation process of achieving complete coverage has been confirmed by independent consultants using thermal imaging techniques. No weight or pressure on plasterboard linings.
installed ‘down the cavity’ have a history of poor coverage with anecdotal evidence of gaps of up to 30%
mineral wool Installation Procedure
Insulbloc Presentation (2)
28/05/2013
6
Insulbloc Features & Benefits
Rockwool is no longer made in Australia and there is anecdotal evidence that there is cheap mineral wool being imported from Asia that is not as hydrophobic as is should be. If in doubt, get a sample tested, don't rely on fake test results.
Insulbloc Presentation (2)
28/05/2013
7
Insulbloc Features & Benefits Long term maintenance
Settlement of insulation will result in gaps and the reduction in effective insulation rating. 5% gaps in insulation coverage can cut the thermal rating in half. Insulbloc exhibits zero settlement due to the installation process and its high compressive strength.
Insulbloc’s insulation rating is less affected by moisture. 1.5% moisture content caused by water vapour reduces fibreglass and mineral wool insulating rating by up to 50% while only affecting polystyrene by approximately 10%. As well, Insulbloc is less likely to become moist as it is 50 times more moisture resistant than mineral wool.
Insulbloc Presentation (2)
28/05/2013
8
Insulbloc Features & Benefits
Insulbloc, being polystyrene, is resistant to fungi and bacteria which can lead sick
building syndrome.
Insulbloc is vermin resistant and less likely to allow large vermin like rats and mice
to live in the wall cavity.
Insulbloc is more moisture vapour resistant resulting in less free moisture
accumulating in the wall cavities reducing the chance of sick building syndrome and timber degradation (which can happen in insulated and uninsulated walls due to the presence of moisture).
Insulbloc is inert with no off gassing of toxic fumes and burns with the same toxicity
as wood.
Insulbloc does not contain any formaldehydes or mineral wool particles. Zero Spread of Flame Fire Rating. Made from fire retarded polystyrene
Insulbloc Presentation (2)
28/05/2013
9
Insulbloc Features & Benefits
Made from 100% recycled fire retarded polystyrene Made in Australia Relatively easy to remove from cavity wall (with
Non-toxic Can be re-used in landfill to improve drainage
Higher Insitu Insulation Rating results in less
Insulbloc Presentation (2)
28/05/2013
10
Peace of Mind
Insulbloc Presentation (2)
28/05/2013
11
Insulb nsulbloc Pro loc Product W duct Warra arranty nty
Jim’s Insulation Services Central Coast War Warra rants nts: ……………………………………................................................................... IN INSULB SULBLOC LOC Insulation installed at the provided address is manufactured to meet the requirements of AS4859.1:2002 and is made from White EPS grade fire retarded polystyrene as per AS 1366 and when installed in the premises at: ………………………………………………………………………………………………... is gu guar arant anteed eed to to be be free fro free from d m def efec ectiv tive mat e material a erial and nd w wor
kmanship, r , rep epel els w wat ater a er and nd wil ill n l not
wick mo ick mois isture a ture acro ross a wal a wall ca l cavity d ity due ue to to its its h hydro rophobi bic p pro ropertie erties, wi , will ll not s not settle and ettle and is is fire fire and and vermin re ermin resis ista tant, a nt, a non non-irrita irritant, ba nt, bacteria teria, fung , fungi, i, moul mould and mi and mild ldew resi resista tant and nt and wil ill l continu
e in in s such uch a stat a state for e for th the exi e existence o tence of th f the e str tructure. ucture. Based on the Australian Wool Testing Authority Test Report 7 – 571317-NN IN INSULB SULBLOC LOC produces a nominal ‘Total/System’ ‘R’ value of R4.5 (with a nominal insulation ‘Material R’ value of R4.0) when installed in a wall or other closed cavity to a thickness of 100mm.‘Total/System’ ‘R’ values include all building materials, air spaces and insulation components. Maximum net coverage of 3.0 m2 per 300 litre bag per 100mm thickness (approx. 3.6 m2 - 4.0 m2 per bag after allowing for wall construction/framing), approximate Thermal Ratings for the following types of wall construction insulated with INSULB SULBLOC LOC: Brick V Brick Venee eneer r with 90mm timber frame and 50mm cavity R6. 6.0 Dou Doubl ble B e Bric rick k with 50mm cavity R2. 2.7 Clad Clad/Weatherboar Weatherboard with 90mm timber frame R4.0 Your IN INSUL SULBL BLOC OC insulation has a ‘hydrophobic’ property which means it repels water and will not track moisture across your wall cavity through capillary or osmotic type action, but the customer is required to maintain all external wall faces free of defects so as not to void this warranty. Mana Manage ger S r Sig ignature nature: …........................................ In Insta tall ll Date: Date: ………………………………………………
36 365 D 5 Day Mo ay Money B ney Back P ack Performa erformance nce Guarantee arantee
Jim’s Insulation Services Central Coast (ABN 37612859793) warrants to: ________________________________________
That our Insulbloc Insulation when manufactured to meet the General and Performance Criteria and Technical Provisions of AS4859.1:2002 and is made from White EPS grade fire retarded polystyrene as per AS 1366 and is installed at
winters day.
Mana Manage ger S r Sig ignat nature ure: ____
____________ ____________ ____
In Insta tall ll Date: Date: ___________________ ______________________________________ ___________________________ _______ Note: Thi
guar arantee w antee wil ill n l not
ffect un unle less sig igned ed and and dat ated ed by t by the M e Mana anage ger
Availability
Insulbloc Presentation (2)
28/05/2013