development of a so x0ray ccd camera system in lhd and
play

Development*of*a*so.*X0ray*CCD* camera*system*in*LHD*and* - PowerPoint PPT Presentation

P067 Development*of*a*so.*X0ray*CCD* camera*system*in*LHD*and* future*plan*to*reinstall*in*KSTAR** C.*Suzuki a ,*K.*Ida a ,*M.*Yoshinuma a ,*S.*Jang b ,*S.*Lee c ,*S.*Hong c ,*and*J.*Kim c * * a Na%onal)Ins%tute)for)Fusion)Science,)Toki,)Japan)


  1. P067 Development*of*a*so.*X0ray*CCD* camera*system*in*LHD*and* future*plan*to*reinstall*in*KSTAR** C.*Suzuki a ,*K.*Ida a ,*M.*Yoshinuma a ,*S.*Jang b ,*S.*Lee c ,*S.*Hong c ,*and*J.*Kim c * * a Na%onal)Ins%tute)for)Fusion)Science,)Toki,)Japan) b Korea)Advanced)Ins%tute)of)Science)and)Technology,)Daejeon,)Korea)) ) c Na%onal)Fusion)Research)Ins%tute,)Daejeon,)Korea)

  2. IntroducLon � ! A*so.*X0ray*imaging*system*using*a*CCD*(Charge*Coupled*Device)*camera*and* beryllium*(Be)*filters*has*long*been*developed*in*the*Large*Helical*Device*(LHD)* at*the*NaLonal*InsLtute*for*Fusion*Science*(NIFS).** ! In*the*imaging*mode,*flux*surface*shape*can*be*reconstructed*from*the* measured*so.*X0ray*image*and*the*equilibrium*database,*from*which*magneLc* axis*posiLon*is*derived.** ! In*the*photon0counLng*mode,*electron*temperature*and*impurity*density*can* be*possibly*derived*from*the*slope*and*line*intensity*of*the*measured*spectra,* respecLvely.* ! Before*launching*deutrium*experiment*in*LHD,*we*are*planning*to*transfer*this* system*to*the*KSTAR*and*reinstall*it*in*an*appropriate*port*flange.** 1 �

  3. Large*Helical*Device*(LHD)* 13.5*m ! Heliotron*type*device*with*NbTi*superconducLng*coils*(<*3*T)* ! Major*radius*=*3.9*m,*Minor*radius*=*0.6*m,*Plasma*volume*=*30*m 3 * ! 5*beamlines*of*NBI*(3*negaLve*and*2*posiLve)* ��

  4. Arrangement*of*a*so.*X0ray*CCD*camera*in*LHD* 3.9*m* Plasma* Viewing*Angle* 6T*port* (tangenLal) * ! The*CCD*camera*was*installed*in*a*tangenLal*viewport*of*the*LHD*to*observe* tangenLal*so.*X0ray*images*of*the*plasmas.* 3 �

  5. Detector*system* Be*filter*disk* 0,*20,*50,*100,*200,* 400,*800,*1600*μm* 4 �

  6. SpecificaLon*of*the*so.*X0ray*CCD*camera* Be*Filter*transmieance*&* CCD*chip* CCD*quantum*efficiency* (frame*transfer)* 99.8%)Be 1 50)µm 70)µm 100)µm 0.8 150)µm 250)µm Transmittance 450)µm 0.6 850)µm 1650)µm QE 0.4 0.2 0 1 10 Photon)Energy)(keV) Model* DO4350BV*(Andor*Technology)* Number*of*pixels* 1024*x*1024*pixels*(frame*transfer)* Pixel*size* 13*μm 2 *(back*illuminated) * Max.*A/D*rate* 1*MHz* Max.*frame*period* 0.25*s*@1MHz,*8x8*binning* 5 �

  7. Previous*installaLon*in*LHD Supersonic*motor* for*the*pinhole* CCD*camera* PneumaLc* Supersonic*motor* shueer* for*the*filter*disk* 6 �

  8. Energy*resolved*imaging*in*a*long*pulse*discharge* 50μm–70μm* Visible*image** So.*X0ray*image** Energy@peak*:*1.9*keV* 50*μm*filter* #84778* 2x2*binning* Z* 850μm–1650μm* R* Energy@peak*:*4.8*keV* AcquisiLon* Lming* ! Frame*transfer*CCD*can*measure*sequenLally*several*images*with*different*cutoff* energies*by*rotaLng*the*filter*disk*during*a*long*pulse*discharge.** ! An*image*for*a*specific*photon*energy*range*can*be*obtained*by*taking*the*difference* between*two*signals*measured*with*adjacent*filter*thicknesses.* 7 � C.#Suzuki,#K.#Ida,#T.#Kobuchi,#and#M.#Yoshinuma,#Rev.#Sci.#Instrum.# 79 #(2008)#10E929.#

  9. DerivaLon*of*magneLc*axis*shi. Be*filter:*450*µm* Measured Pinhole:*0.05*mm R ax v *=*3.85*m repeLLve*pellet best*fit*@*<β>=1.19% Fieed ! MagneLc*axis*shi.*(Shafranov*shi.)*can*be*derived*from*the*best*fit*of*the*pre0calculated* VMEC*equilibria*to*the*measured*so.*X0ray*profile*assuming*that*the*emissivity*profile* could*be*expressed*by*Fourier0Bessel*expansion.* 8 � C.#Suzuki,#K.#Ida,#R.#Sakamoto,#M.#Yoshinuma#and#the#LHD#Experiment#Group,#Nucl.#Fusion# 50 #(2010)#064013.#

  10. Impurity*hole*in*a*high*T i *plasma 2.0–2.25*s Be*filter:*450*µm* Pinhole:*0.1*mm 2.25–2.5*s 50000 2.0–2.253s 40000 30000 Counts 2.25–2.53s 20000 10000 0 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 R3(m) ! Hollow*so.*X0ray*emissivity*profiles*are*o.en*observed*in*high*ion*temperature* discharges*together*with*the*formaLon*of*carbon*impurity*hole. 9 � K.#Ida#et#al.,#Phys.#Plasmas# 16* (2009)#056111.#

  11. Photon*counLng*mode*for*energy*spectra CalibraLon*by*X0ray*Source Dark,charge Energy*spectra*in*LHD 150 Fe 55 Am 241 Ti Cr Fe Mn,K α Number,of,pixels 100 5.89,keV Np,L α 13.93keV 50 Np,L β 17.75keV 0 0 500 1000 1500 2000 2500 3000 Count SensiLvity:*12*eV/count* Energy*resoluLon:*360*eV ! SpaLal*and*energy*resoluLons*higher*than*those*of*PHA*can*be*obtained*by*operaLng* the*so.*X0ray*CCD*camera*in*the*photon*counLng*mode.* ! The*three*K α *lines*from*Ltanium*(4.8*keV),*chromium*(5.7*keV),*and*iron*(6.6*keV)* appear*in*so.*X0ray*energy*spectra*measured*in*LHD.* 10 � Y.#Liang#et#al.,#Rev.#Sci.#Instrum.# 72 #(2001)#717.##

  12. Candidate*viewing*ports*in*KSTAR Seems*not*to*cover* the*edge*region F0port* B0port* Viewing*range* Viewing*range 11 �

  13. Issues*to*be*solved*for*the*installaLon*in*KSTAR � ! Stacking*the*neutron*shield*blocks*to*protect*the*CCD*camera*near*the*port* flange.* ! Supplies*of*evacuaLon*system,*cooling*water,*pressurized*air,*etc.* ! InstallaLons*of*peripheral*devices*such*as*gate*valves,*shueer*and*filter*wheel* would*be*difficult*due*to*narrow*space*around*the*candidate*ports.** ! The*enLre*system*including*the*field*of*view*should*be*redesigned.*More* compact*system*(e.g.,*without*filter0wheel/driving*system)*may*be*favorable.* ! Cross0checking*the*space*availability*and*interference*issues*on*the*CAD* drawing*is*necessary.* 12 �

  14. Summary*&*future*plans* ! The*diagnosLc*system*using*a*so.*X0ray*CCD*camera*and*Be*filters*had*been* uLlized*in*LHD*for*mulLpurpose*uses.* ! Two*operaLng*modes*of*the*camera*can*be*used*properly*for*the*purposes*we* need.*The*camera*had*been*mainly*used*in*the*imaging*mode*for*the*tasks*such* as*Shafranov*shi.*measurement,*energy*resolved*imaging*in*a*long*pulse* discharge,*and*hollow*emissivity*profile*in*a*discharge*with*impurity*hole.* ! The*photon0counLng*mode*is*also*available*for*the*measurements*of*so.*X0ray* energy*spectra*with*high*sensiLvity*and*energy*resoluLon*calibrated*using* standard*X0ray*source.* ! The*system*has*already*been*uninstalled*from*LHD,*and*we*will*transfer*this* system*to*the*KSTAR*and*reinstall*it*in*an*appropriate*port*flange.*The*enLre* system*including*the*field*of*view*should*be*redesigned.** 13 �

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.