innovative environmental solutions I Post-Fire Water Quality I Monitoring at Solid Waste Disposal Facilities C. KBL Post-Fire Hydrogeological Assessment of Site Third party review of the fire monitoring data (Beckingham Hay River Landfill


slide-1
SLIDE 1

innovative environmental solutions

Post-Fire Water Quality Monitoring at Solid Waste Disposal Facilities

I

I

  • C. KBL
slide-2
SLIDE 2

Post-Fire Hydrogeological Assessment of Site

Third party review of the fire monitoring data (Beckingham Hay River Landfill Fire – Environmental Monitoring Report) provided results and recommendations. The Town proposes a Study covering the following:  Surface Water  River Water  Groundwater

O KBL

slide-3
SLIDE 3

Riser

2

sw ,_

SW 11

$ SNP0053-5"

SW10

S-SNP0063-5c

SW2 SNP005:1.-7d

Si

SNP0053-7c

$ /

S Nl'0053-7b

~ _, SNP0053-7a

  • SW?

SW13

S5NP0053-5e

sw,

SW9 River 1

':J.i'.1!>..ru !J! .iJ400 !.f ..iJ.:.JJJ !h:.l!iCtl ':JjYhU 1 Jl.i~oo !J!i.!J..i~ !h:.ltcu JJ.:J fW ';Jj:JJIY.I 1 Jlo~!,,{I !J!.i--~ !h'..l:t-:.-u

~u

':,li.$1.l!F.I !.i!;.:1100 !,,t=..i,:IIJ JJ ~ u '.l..i-{81.1 1 Jli-4:JIY.I !.f ..
  • .:rJJJJ
!.'Av.-J ~ JU F~ li 11,:1(ml

::

. Bediingham El'llliromnental

FIGURE 5:

LOCATIONS OF SURFACE_ RIVER AND GROUNDWATER MONITORING LOCATIONS SUPERIMPOSED ON AERIAL PHOTOGRAPH Date: 4-FEB-2020

PROJECT INFORMATION

LOCATION:

Hay River Municipal Solid Waste Facility H:.ty River, NT

PROJECT NO.:

BE-20003

CLIENT NAME:

KBL Env'ironmental

DRAWN BY: CHECKED BY: y _ Fauli

  • R. Dunkley

r.:.,

  • LEGEND

Groundwater Monitoring We,11 Location

Surface Waier Monitoring Loca1 ion River Wa.ter Mo,, itori.ng Location Estimated Fire Location

slide-4
SLIDE 4
  • 1. Surface Water

 At Landfill Fire Site (SW13, SW1, and SW7):

 Conduct a one-time surface water sampling program on the landfill during the upcoming spring snowmelt runoff event. Analyze for dioxins and furans, total metals, PAHs, VOCs, and routine parameters.  Should the parameters not exceed guidelines no further sampling will be conducted.

 Soil Sampling at Landfill Fire Site:

 Conduct a one-time sampling program and SW13, SW1, and SW7 at 0 – 15cm depth. This is to assess potential residual soil contamination from the fire. Conducted at the same time as the surface water sampling above. Analyze for dioxins and furans, total metals, PAHs, VOCs, and routine parameters.  Should the parameters not exceed guidelines no further sampling will be conducted.

O KBL

slide-5
SLIDE 5
  • 1. Surface Water cont.

 Upstream of the Landfill (SW5 and SW9)

 Conduct confirmatory upstream river sampling program to confirm the elevated total metals and routine parameters found at upstream river samples are background concentrations.

 Downstream of the Landfill Fire (SW2, SW10, SW11, SW12, SW14, SW8, SW6, and SW3)

 The elevated routine parameters found downstream of the landfill were also found upstream and may not be directly related to the 2019 landfill

  • fire. The sampling of the river upstream will confirm if it is background

concentrations.

O KBL

slide-6
SLIDE 6
  • 2. River Water

 Conduct a one-time river sampling program at River-1, River-2 and River-3 after snowmelt runoff and any precipitation event  Analyze for dioxins and furans, total metals, and routine parameters.  If the parameters do not exceed guidelines, there is no need for further sampling

O KBL

slide-7
SLIDE 7

~

Ri~er 'h''aler Monitoring Localion

RIVER SAMPLE LOCATIONS Hay River Municipal Solid Waste Facility, Hay River. NT

JOO No . 6 E-20O::J3 Oatc 4-FEG-2020

0 Surface W ater Monitoring

LDC.3lion 1~

1

=.:=.:============;;;==========~I

DR-.ot,N [;Y: RD

(.J H Fr".KF.D F.l",": 'ti'F
slide-8
SLIDE 8
  • 3. Groundwater

 Routine Water Analysis

 Cl levels will continue to be monitored at the Site as part of the on- going groundwater monitoring program. Will continue to monitor Cl levels.

 Petroleum Hydrocarbons

 Monitor the 0053-5c, 5d, and 5e groundwater wells semi-annually for PHCs.

 Volatile Organic Compounds

 Continue to monitor VOCs at 0053-5c and 5d.

 Dioxin and Furans

 Sample for dioxin and furan sampling for the next spring and fall monitoring events. Results to be assessed after the data has been review.

O KBL

slide-9
SLIDE 9

Results Analysis and Reporting

The findings of the Study will be reported as part of the 2020 Annual Report. Should further actions (i.e. environmental management plan or continued monitoring) it will be submitted to the Board either as soon as it is determined (environmental management plan) or as part of the Study results (continued monitoring).