Third party review of the fire monitoring data (Beckingham Hay River Landfill Fire – Environmental Monitoring Report) provided results and recommendations. The Town proposes a Study covering the following: Surface Water River Water Groundwater
Riser
2
sw ,_
SW 11
$ SNP0053-5"
SW10
S-SNP0063-5c
SW2 SNP005:1.-7d
Si
SNP0053-7c
$ /
S Nl'0053-7b~ _, SNP0053-7a
SW13
S5NP0053-5e
sw,
SW9 River 1
':J.i'.1!>..ru !J! .iJ400 !.f ..iJ.:.JJJ !h:.l!iCtl ':JjYhU 1 Jl.i~oo !J!i.!J..i~ !h:.ltcu JJ.:J fW ';Jj:JJIY.I 1 Jlo~!,,{I !J!.i--~ !h'..l:t-:.-u~u
':,li.$1.l!F.I !.i!;.:1100 !,,t=..i,:IIJ JJ ~ u '.l..i-{81.1 1 Jli-4:JIY.I !.f ..::
. Bediingham El'llliromnental
FIGURE 5:
LOCATIONS OF SURFACE_ RIVER AND GROUNDWATER MONITORING LOCATIONS SUPERIMPOSED ON AERIAL PHOTOGRAPH Date: 4-FEB-2020
PROJECT INFORMATION
LOCATION:
Hay River Municipal Solid Waste Facility H:.ty River, NT
PROJECT NO.:
BE-20003
CLIENT NAME:
KBL Env'ironmental
DRAWN BY: CHECKED BY: y _ Fauli
◊
r.:.,
Groundwater Monitoring We,11 Location
Surface Waier Monitoring Loca1 ion River Wa.ter Mo,, itori.ng Location Estimated Fire Location
At Landfill Fire Site (SW13, SW1, and SW7):
Conduct a one-time surface water sampling program on the landfill during the upcoming spring snowmelt runoff event. Analyze for dioxins and furans, total metals, PAHs, VOCs, and routine parameters. Should the parameters not exceed guidelines no further sampling will be conducted.
Soil Sampling at Landfill Fire Site:
Conduct a one-time sampling program and SW13, SW1, and SW7 at 0 – 15cm depth. This is to assess potential residual soil contamination from the fire. Conducted at the same time as the surface water sampling above. Analyze for dioxins and furans, total metals, PAHs, VOCs, and routine parameters. Should the parameters not exceed guidelines no further sampling will be conducted.
Upstream of the Landfill (SW5 and SW9)
Conduct confirmatory upstream river sampling program to confirm the elevated total metals and routine parameters found at upstream river samples are background concentrations.
Downstream of the Landfill Fire (SW2, SW10, SW11, SW12, SW14, SW8, SW6, and SW3)
The elevated routine parameters found downstream of the landfill were also found upstream and may not be directly related to the 2019 landfill
concentrations.
Conduct a one-time river sampling program at River-1, River-2 and River-3 after snowmelt runoff and any precipitation event Analyze for dioxins and furans, total metals, and routine parameters. If the parameters do not exceed guidelines, there is no need for further sampling
~
Ri~er 'h''aler Monitoring Localion
RIVER SAMPLE LOCATIONS Hay River Municipal Solid Waste Facility, Hay River. NT
JOO No . 6 E-20O::J3 Oatc 4-FEG-2020
0 Surface W ater Monitoring
LDC.3lion 1~
1
=.:=.:============;;;==========~I
DR-.ot,N [;Y: RD
(.J H Fr".KF.D F.l",": 'ti'F Routine Water Analysis
Cl levels will continue to be monitored at the Site as part of the on- going groundwater monitoring program. Will continue to monitor Cl levels.
Petroleum Hydrocarbons
Monitor the 0053-5c, 5d, and 5e groundwater wells semi-annually for PHCs.
Volatile Organic Compounds
Continue to monitor VOCs at 0053-5c and 5d.
Dioxin and Furans
Sample for dioxin and furan sampling for the next spring and fall monitoring events. Results to be assessed after the data has been review.
The findings of the Study will be reported as part of the 2020 Annual Report. Should further actions (i.e. environmental management plan or continued monitoring) it will be submitted to the Board either as soon as it is determined (environmental management plan) or as part of the Study results (continued monitoring).