- Energising India since 1969
An ISO 9001:2008 Company
An ISO 9001:2008 - - PowerPoint PPT Presentation
An ISO 9001:2008 Company Energising India since 1969
An ISO 9001:2008 Company
2
3
(-./: Technical Associates Ltd. is founded (-.-: TA gets it’s first order for manufacturing 5 kVA, 11KV Distribution Transformers (-/0: Present manufacturing location at Lucknow established (-/-: TA sets up first Transformer unit in Punjab at Sangrur (-)1: Indian Transformer Manufacturers’ Association (ITMA) set up with as a (--(: TA gets 23'- certification for complete transformer manufacturing process (: TA becomes regular manufacturer of 40.0 MVA, 132 kV Power Transformers .: Manufacturing activities certified by BSI, UK as complying to 23'-(, standards .,Turnkey Power Projects division set up for executing Transmission & Distribution EPC projects. /,Work commences on setting up a state of the art manufacturing plant in Sitarganj, Uttarakhand for manufacture of Extra High Voltage Power transformers up to 400 kV class. ),State of the art plant commissioned at Sitarganj (Uttarakhand). It will enlarge TAL’s transformer product portfolio to include EHV Transformers up to 400 kV; a quantum leap in manufacturing and technology.
4
Switzerland). (, Both plants of TAL certified for compliance with ISO 9001:2008 standard. ((, TAL delivers it's first 100 MVA 220/132 kV Auto Transformer to APTRANSCO. ((,TAL executes it's first export order for Power Transformers for 4"3#'*4. ((,TAL successfully type tested for 160 MVA, 220/132 kV voltage class Power Transformer by ERDA Vadodra. (,TAL executes export order for Power Transformers for Tokai Power Products Ltd., 5& and Distribution Transformation for ABERME, Republic of 5*% (,TAL installed UP's first 2 MWp Solar Photovoltaic Power plant in District Barabanki Inaugurated by Honorable Chief Minister of Uttar Pradesh. (0, TAL executes export order for Power & Distribution Transformers for "& * (0,TAL received an approval from RDSO for manufacturing and supply of Traction Power Transformers upto 30MVA, 220 KV Voltage class. (0,TAL received an approval from 62. for supply of 1 Ph. & 3
Transformer sales Project Execution
5
Sales Network
8& &#
00 1 3.15 MVA 33/11 kV 2 5 MVA 33/11 kV 3 6.3 MVA 33/11 kV 4 7.5 MVA 33/11.5 kV 5 8.0 MVA 33/11 kV 6 10 MVA 33/11 kV 7 20 MVA 33/11.5G6.25 kV .. 1 12.5 MVA 66/11 kV 2 12.5/ 16 MVA 66/11 kV 100 MVA, 220/132/11 kV Power Transformer
7
3 20 MVA 66/11 kV 4 16/ 20 MVA 66/11 kV 5 25/ 31.5MVA 66/11 kV (0 1 10/16 MVA 132/11 kV 2 12.5 MVA 132/11 kV 3 20 MVA 132/11 kV 4 20/25 MVA 132/33 kV 5 31.5 MVA 132/33 kV 6 40 MVA 132/33 kV
60 MVA 220/132/11 kV 2 100 MVA 220/132/11 kV 3 160 MVA 220/132 kV 12.5 MVA, 66/11 kV Power Transformer 40 MVA, 132/33 kV Power Transformer
37 8& &#
1 10 kVA 11/0.433 kV 2 15 kVA 11/0.433 kV 3 16 kVA 11/0.433 kV 4 25 kVA 11/0.433 kV 5 40 kVA 11/0.433 kV 6 63 kVA 11/0.433 kV 7 100 kVA 11/0.433 kV 8 200 kVA 11/0.433 kV 9 250 kVA 11/0.433 kV 10 250 kVA 33/0.4 kV 11 300 kVA 11/0.433 kV
8
aluminum winding, though copper wound transformers can be manufactured if required
11 300 kVA 11/0.433 kV 12 315 kVA 11/0.433 kV 13 400 kVA 11/0.433 kV 14 400 kVA 6/0.42 kV 15 400 kVA 11/0.42 kV 16 500 kVA 11/0.433 kV 17 630 kVA 11/0.433 kV 18 750 kVA 11/0.433 kV 19 1000 kVA 11/0.433 kV 20 1500 kVA 11/0.433 kV 21 2000 kVA 11/0.433 kV 8 MVA, 33/11 kV Distribution Transformer Distribution Transformers (11 kV) Distribution Transformers (33 kV)
37 8& &#
1 5 kVA 6.3/0.240 kV 2 5 kVA 25/0.240 kV 3 5 kVA 11/√3 kV/240 kV 4 10 kVA 6.3/0.240 kV 5 10 kVA 25/0.240 kV 6 10 kVA 11/0.250 kV 7 16 kVA 6.3/0.240 kV 8 25 kVA 6.3/0.240 kV 9 50 kVA 6.3/0.240 kV
9
copper or aluminum or composite windings
also manufactured
Ready cut core Slitting and cutting Annealing Aluminum / Copper rod Bare Strip / Wire to size Paper covering for Strip / Wire Coil winding LV & HV Press Board, Insulating paper, Permawood Slit paper, blocks, spacers, supports, strips Tanking
Fabricated Tank
11
End frame fabrication Core assembly Coil pre heating & pressing Core coil assembly Ratio check Main assembly connections Ratio Check Vacuum Drying/ Vapour Phase Drying Oil filling Filtration Testing Inspection Dispatch
– Core processing (Slitting, Cutting and Annealing) – Conductor manufacturing (Drawing, Annealing and Paper covering) – Transformer oil processing – Tank fabrications – Winding – Assembly and tanking
12
Distribution Transformer Bay Power Transformer Test Station Paper Covering facility for conductor Power Transformer Bay
## designed especially for high quality large Core Assembly %& for handling heavy weight coil winding at variable speeds upto 10.0 MT capacity
Complete facilities for 2&:&
Complete facilities for &8: 8&#: for use in Transformer windings +& machines for Winding conductor
Cranes of 5, 10, 25, 35, 150 MT lifting capacity
Power Transformer Assembly
Power Transformer Assembly Sheds with adequate space and roof heights for fast processing
11 kV transformer assembly 33 kV transformer assembly 66/ 132 kV Assembly & Testing
Core Slitting, cutting, annealing 66/ 132/ 220/ 400 kV Impulse Test Area 220/ 400 kV Assembly
18 New Plant in Uttarakhand, North India
Central Store
Winding ! Insulation Processing
– Single phase and Three phase 11 kV distributions transformer – Three phase 33 kV distribution transformer – Three phase 66 & 132 kV power transformer – Single phase and three phase 220 to 765 kV power transformer
–
Coil winding
–
Insulation processing
–
Mild steel fabrication
–
Impulse testing setGup
19
–
Impulse testing setGup
transformer per day
Distribution Transformer Bay Power Transformer Test Station Material Handling Facility up to 300MT (2 X 150) Power Transformer Bay
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
"@"8"3267!"7627""8276"
38'768!
products in house
developed inGhouse including the 220 kV & 132 kV transformers
transformer designs are done on the basis of inGhouse developed software
AutoCad & Solidworks are used extensively
Impulse Voltage Withstand Capability tests at 3rd party, Government accredited Laboratories like CPRI (Central Power Research Institute)
cleared 3rd party short circuit tests, amongst companies of TAL s size
37 & A B "= 1
GM (Technical) M.E. (Elect) 38
2
B.Sc. (Elect. Eng.) 45
3
Director B.E. (Elect. Eng.) 42
4
Plant Head B.E. (Elect.) 39
5
General Manager B.E. (Mechanical) 37
6
Deputy General Manager BE (Electrical Engg.) 14
7
Deputy General Manager Diploma in Electrical 15
8
Deputy General Manager B.Tech (Electrical) 18
37
"#$%&'#&#%()&*&&+*,-)&.#& TAL’s size
9
Manager B.Tech (Mechanical) 20
10
B.Tech (Elect) 5
11
B.Tech (Elect)+Pursuing M.Tech 3.6
12
B.A.+ ITI 6
13
B.A.+ ITI 5
14
Engineer BE(Power Electronics) 7
15
Engineer
2
16
Engineer Diploma in Mechanical 3
17
Trainee Engineer B.Tech (Mech)+Pursuing MBA 2
18
Trainee Engineer
1
19
Trainee Engineer M.E. (High Voltage) 0.1
20
Trainee Engineer M.E. (High Voltage) 0.1
21
Draftsman ITI & Diploma (Mech) 3
'"82"%
Lucknow and Sitarganj plant.
routine tests and temperature rise tests as per international standards like IS 2026 and IEC 60076.
Rise & Impulse test, and specialised tests such as FRA, Noise & Vibration measurement, etc.
independent test centers).
generators (1600 kVp, 160 kJ and 900 kVp, 45 kJ) from Haefely, Switzerland with expandable capacity to test transformers of 765 kV voltage class.
Impulse Testing
38
Testing with Yokogawa Power Analyzer Impulse Testing Facility
39
#
Grade of Material Laminations Burr Level Pocket Height & Tolerance Clamp Plate / Tie Road Dimensions & Material
%&
Transposition Concentricity of Blocks G Axially & Radially Proper Ducts for Cooling & Voltage Withstand Measurement of Winding Resistance Pressure & Vacuum Tests
&
Electrical Clearances in Oil & Air Core & Coil Assembly Locking at Tank Base & Tank Cover Core Earthing
8 23,.:2"#,./. # C
RSG Test at Low VoltageG To Ensure Insulation Requirement at Different Points SFRA Test to ensure Healthiness of Core, Coil & AssemblyG At our Works & At Site Temperature Rise Test & Impulse Voltage withstand Tests G at least on one unit of each design
40
Dye Penetration Test on Lifting Components (optional)
#; # ! 6
Radial & Axial Gap Measurements G as per CoreGCoil Drg. Checking of Cable, Flats Dimensions & Paper Insulation Thickness Route of Cables, Flats & their Gaps w.r.t End Fames, Tank, Coils, OLTC, Earth Points etc. Measurement of Ratio, Winding Resistance, Magnetizing Current, Vector Group, %Z & Load Loss, CoreGIsolation All Taps Resistance Measurement to ensure joints Healthiness
&
At 100°C ± 5°C & upto 1.0 torr Vacuum Meggar & PI Values Measurements after Core & Coil Assembly Processing Measurement of Surface Temperature by Non Contact Type Electronic Gun DGA Test before & After Heat Run Test S/C Test as per IS:2026/IEC:60076 – on Customer request Over Excitation of Transformer at 125% Rated Measurement of Magnetizing Current at Low Voltage Magnetic Balance Test Measurement of Polarization Index
enhance and capitalize Technical Associates’ strong presence in the power T&D sector
conceptualization , design, engineering, procurement, erection and commissioning
Distribution & Transmission lines from LT (440 V) to 220 kV, and electrical Substations from 11 kV to 220 kV
66 kV Sub@station with TAL transformer 132 kV Sub@station under construction
42
tendering, engineering, execution, erection, commissioning and testing
66 kV Sub@station at Mohra, Haryana
/, /,
Director Director
44
GM (Sales@ Marketing) GM (Sales@ Marketing) GM (Finance) GM (Finance) GM (Technical) GM (Technical) Quality Head Quality Head Plant Head (Sitarganj) Plant Head (Sitarganj) GM (Production) GM (Production) GM HR GM HR Head@ Material Management Head@ Material Management Head@ IT Head@ IT CEO (Projects) CEO (Projects)
45
TAL Engineers & Managers at the Lucknow Corporate Office
#3'"83"6"73
Key customer segments catered by TAL include:
companies
total turnover of the company
>"B#3'"83
46
total turnover of the company
& Tested successfully for all Routine & Type (including 8! 2&) Tests.
Transformer for PSEB & 31.5/25 MVA, 66/11 KV Transformer for HVPNL have been tested for all Routine, Type & Special Tests; including Short Circuit Test.
at Sitarganj.
kV by UPPTCL.
Impulse Voltage test in (
47
Circuit Test in (
to various customers so far).
since 1997.
dryness of the winding.
Stray Losses Boltless Core – Low No Load & Low Magnetizing Current.
Transformer by ERDA Vadodra.
Power Transformers upto 30MVA, 220 KV Voltage class by 83'
KV Class by 62. (PGCIL)