P50 S50 S11 P ersistence S40 in P50 P erfect S12 S30 P - - PowerPoint PPT Presentation

p50
SMART_READER_LITE
LIVE PREVIEW

P50 S50 S11 P ersistence S40 in P50 P erfect S12 S30 P - - PowerPoint PPT Presentation

P50 S50 S11 P ersistence S40 in P50 P erfect S12 S30 P erformance S22 S20 Competitor SAMSUNG Mindray GE GE Sonoscape DC-8Exp Logiq P9 HS70A P50 Voluson S8 CONTENTS 1 1 2 3 Consistent Quality Exceptional Mobility with


slide-1
SLIDE 1

P50

slide-2
SLIDE 2

S11 S12 S20 S22 S30 S40 S50

P50

Persistence

in

Perfect Performance

slide-3
SLIDE 3

Mindray DC-8Exp Sonoscape P50 SAMSUNG HS70A GE Logiq P9

Competitor

GE Voluson S8

slide-4
SLIDE 4

Exceptional Mobility with Compact Design Consistent Quality Performance Across Applications Tailored Solutions For Various Applications

CONTENTS

1 2 3 1

slide-5
SLIDE 5

Exceptional Mobility with Compact Design

766mm 1325mm

slide-6
SLIDE 6

Exceptional Mobility with Compact Design

21.5 inch high resolution LED color monitor 13.3 inch touch screen, more sensitive

slide-7
SLIDE 7

Exceptional Mobility with Compact Design

30cm

Reduce doctors arm movement and fatigue

slide-8
SLIDE 8

Exceptional Mobility with Compact Design

Patient management and advanced function Standard keyboard Mode keys Space for hand wrist

slide-9
SLIDE 9

Exceptional Mobility with Compact Design

Tailor-made probe holders Cable management Gel-Warmer 5 probe connectors

slide-10
SLIDE 10

Exceptional Mobility with Compact Design

1090mm

  • Built-in battery
  • Easy to move
  • Convenient to transport
slide-11
SLIDE 11

Exceptional Mobility with Compact Design Consistent Quality Performance Across Applications Tailored Solutions For Various Applications

CONTENTS

1 2 3 2

slide-12
SLIDE 12

Consistent Quality Performance Across Applications

C-Field Beam Smart Dynamic Color μ-Scan imaging Single Crystal Transducer

slide-13
SLIDE 13

Single Crystal Transducer

Singles Crystal Transducer

  • Wider bandwidth
  • Higher sensitivity
  • Better penetration
  • Higher S/N
Single Crystal traditional Convex
slide-14
SLIDE 14

Single Crystal Transducer

3C-A C1-6

slide-15
SLIDE 15

μ-Scan imaging

1st 2nd

3rd

4th

Adaptive Edge Identification Adaptive Speckle Noise Reduction Tissue Feature Extraction Edge Judgment Laplacian Pyramid

(Image decomposition)

μ-Scan

slide-16
SLIDE 16

μ-Scan imaging

μ-Scan off μ-Scan on

slide-17
SLIDE 17

C-Field Beam

  • Dynamic continuous focusing
  • Better out-of-focus image resolution and

penetration

- C-Field Beam Former - Traditional US Beam

  • Limited focus area within one image;
slide-18
SLIDE 18

C-Field Beam

Excellent image resolution and penetration

slide-19
SLIDE 19

-Show better color performance by adaptively matching technology -Improve the color sensitivity for Lower velocity

Tissue

Noise

Color

Noise

Tissue Color

Smart Dynamic Color

slide-20
SLIDE 20

Exceptional Mobility with Compact Design Consistent Quality Performance Across Applications Tailored Solutions For Various Applications

CONTENTS

1 2 3 3

slide-21
SLIDE 21

OB/GYN

Tailored Solutions For Various Applications

OB/GYN RADIOLOGY CARDIOVASCULAR

slide-22
SLIDE 22

OB/GYN

01 02 03

◼ S-Live S-Live silhouette S-Depth S-Skeleton Depth Multi-Slice ◼ Multi-Slice C-Plane AVC Follicle Auto face Auto NT ◼ S-Guide

OB/GYN

slide-23
SLIDE 23

OB/GYN

S-Live

More information visible More realistic Shadows Support a virtual light source

slide-24
SLIDE 24

OB/GYN

S-Live

slide-25
SLIDE 25

OB/GYN

S-Live silhouette

Increase the border of tissue Observe the inner structure without edit

slide-26
SLIDE 26

OB/GYN

S-Live silhouette

slide-27
SLIDE 27

OB/GYN

S-Depth

Various color map show the different depth; Convenient to judge the position of the organization along the depth direction

slide-28
SLIDE 28

OB/GYN

S-Skeleton Depth

◼ Removed soft tissue automatically, display skeleton more obviously ◼ Added depth information, display more realistic

slide-29
SLIDE 29

OB/GYN

Multi-Slice

Make the diagnosis more standardized Stack of parallel 2D images in different direction from 3D volume data Easy to interpret anatomical structure A B C

slide-30
SLIDE 30

OB/GYN

C-Plane

Conveniently observe the plane which are not easy to be obtained Provide more abundant and intuitive information A B

slide-31
SLIDE 31

Auto face

OB/GYN

slide-32
SLIDE 32

AVC Follicle

OB/GYN

  • Improve diagnostic efficiency
  • Reduce dependence on operator
  • Improve diagnostic confidence.

( Advanced Volume Calculation )

Auto NT

slide-33
SLIDE 33

S-Guide

OB/GYN

Standard planes Scanning reminder Increase confidence Improve efficiency

slide-34
SLIDE 34

OB/GYN

S-Guide

slide-35
SLIDE 35

OB/GYN

Tailored Solutions For Various Applications

RADIOLOGY CARDIOVASCULAR RADIOLOGY

slide-36
SLIDE 36

Radiology

Contrast Imaging

  • Easy to identify lesion
  • Simultaneous view and timer
  • Available on:3C-A, C1-6
slide-37
SLIDE 37
  • Quick access to the position
  • Rapid calculation of Strain Ratio
  • Intelligent Strain Curve
  • Available on: L742,12L-A,3C-A,6V3,C613, EC9-5,BCC9-5

Radiology

C-xlasto Imaging

slide-38
SLIDE 38

Radiology

Real-time Color Panoramic

  • Available on: L742,12L-A,3C-A,C1-6,6V3,6V3A,C613,VE9-5,VC6-2 (only L742,12L-A support color panoramic)
slide-39
SLIDE 39

OB/GYN

Tailored Solutions For Various Applications

RADIOLOGY CARDIOVASCULAR CARDIOVASCULAR

slide-40
SLIDE 40

Cardiovascular

Tissue Doppler Imaging

  • Show myocardial motion by color code
  • Quantitative analysis of regional myocardial motion
slide-41
SLIDE 41

Anatomic M Mode

Cardiovascular

  • Up to 3 M-Mode lines displayed simultaneously;
  • Easy to get better images for difficult patient
slide-42
SLIDE 42

Color M Mode

Cardiovascular

  • Provide the direction of flow on M mode
slide-43
SLIDE 43

Stress Echo

Cardiovascular

  • Versatile exercise and pharmacologic

protocols;

  • Wall motion scoring and reporting.
slide-44
SLIDE 44

Cardiovascular

Auto EF

  • Automatic calculate LV function through auto

trace

  • Greatly improved the productivity of LV

measurement

  • Improved the efficiency ,accuracy and

repeatability

slide-45
SLIDE 45

Cardiovascular

  • Automatically identify the vessel intima &

media structure and measurement the thickness

  • Improved the efficiency ,accuracy and

repeatability

  • No operator dependent

Auto IMT

slide-46
SLIDE 46

P50

Mobility  Excellent 2D image for high frequency probe  High color flow sensitivity Excellent image quality  slim with battery and 5 probe connector Advanced rendering mod  S-live silhouette  S-skeleton depth

slide-47
SLIDE 47

Thank you