MicroBooNE status Pawel Guzowski The University of Manchester DAQ - - PowerPoint PPT Presentation

microboone status
SMART_READER_LITE
LIVE PREVIEW

MicroBooNE status Pawel Guzowski The University of Manchester DAQ - - PowerPoint PPT Presentation

MicroBooNE status Pawel Guzowski The University of Manchester DAQ uptime POT-weighted DAQ uptime Delivered POT 1 2 Uptime fraction 18 Delivered POT x10 1.8 0.95 1.6 1.4 0.9 1.2 1 0.85 0.8 0.6 0.8 0.4 0.2 0.75 0 Sep 22 Sep


slide-1
SLIDE 1

MicroBooNE status

Pawel Guzowski The University of Manchester

slide-2
SLIDE 2

DAQ uptime

4 October 2018 Pawel Guzowski 2

POT delivered since 9/17: 1.745 e19 POT on tape: 1.603 e19 Fraction on tape: 91.8% We have been taking BNB data since September 17th

Sep 22 Sep 29 Date 0.75 0.8 0.85 0.9 0.95 1 Uptime fraction

POT-weighted DAQ uptime

Sep 22 Sep 29 Date 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 2

18

Delivered POT x10

Delivered POT

slide-3
SLIDE 3

Computing resource use

4 October 2018 Pawel Guzowski 3

Also over summer: As part of tape shortage mitigation, MicroBooNE deleted 500TB of obsolete data

slide-4
SLIDE 4

Summer shutdown activities

  • 15 new DAQ servers installed

– Replacing old ones out of warranty – Old ones are being loaned to SBND for development work

  • 5 power outages

– 3 initially planned – 1 postponed at the last minute, after already ramping down in preparation – 1 unplanned outage due to Feeder 45 glitch

  • Calibration runs

– Laser maintenance work followed by calibration runs over multiple weeks – Unbiased trigger runs at lower drift voltage and purity

  • More off-beam cosmic data taken than in previous summers

– Thanks to our DAQ team for upgrading capability to take a high cosmic trigger rate, following request from physics analysis groups

  • David Caratelli (FNAL) has retired as Run Coordinator; Mark Ross-

Lonergan (Columbia) joins team as Deputy Run Coordinator

4 October 2018 Pawel Guzowski 4

slide-5
SLIDE 5

Recent reduction of argon purity

  • On September 4th, bad argon delivery was made into external

top-up dewar, with ~100ppm O2 contamination

– Levels were recorded but not alarmed on – First time this has happened in >3 years operation

  • 20 gallons entered our cryostat on September 24th

– Caught quickly by shifters and runco team – ND cryo team immediately responded and stopped flow into vessel

  • Top-off is needed to maintain liquid level in vessel. We need

argon dewar drained and refilled before liquid level drops to a point where detector cannot operate. Working with procurement

– Yesterday external vendor came and performed this task

  • MicroBooNE has been running 24/7 and staffing shifts

throughout

– Valuable calibration & systematic evaluation data at lower purity

  • We continue to see tracks throughout this period
  • We currently have ~3ms lifetime

– Estimate ~1 week to return to >15ms lifetime from before the purity degradation

4 October 2018 Pawel Guzowski 5

event display from Sep 27

drift direction

Fiducial width of detector

9/24

20%

10/3

slide-6
SLIDE 6

Recent & upcoming publications

  • Two publications submitted to journals over summer:
  • “Comparison of νµ-Ar multiplicity distributions observed by

MicroBooNE to GENIE model predictions”

– Submitted to Europhysics Journal C; arXiv:1805.06887

  • “A Deep Neural Network for Pixel-Level Electromagnetic Particle

Identification in the MicroBooNE Liquid Argon Time Projection Chamber”

– Submitted to Physical Review D; arXiv:1808.07269

  • In collaboration-wide review:

– “First Measurement of Muon Neutrino Charged Current Neutral Pion Production on Argon with the MicroBooNE LArTPC” – “Rejecting cosmic background for exclusive neutrino interactions studies with LArTPC” – “Design and Construction of the MicroBooNE Cosmic Ray Tagger System”

  • We also released 10 public notes over summer

4 October 2018 Pawel Guzowski 6