A New Energy Solution New England Roundtable Bloom Energy Server Solid Oxide Fuel Cell Clean Reliable Proven Targeted How It Works Convert fuel directly into electricity without combustion Blooms Fuel Cell Conventional


slide-1
SLIDE 1

A New Energy Solution – New England Roundtable

slide-2
SLIDE 2

Bloom Energy Server – Solid Oxide Fuel Cell Clean Reliable Proven Targeted

slide-3
SLIDE 3

How It Works

Inefficient = Less Electricity

Bloom’s Fuel Cell

Efficient = More Electricity

Electrochemical Reaction (Electrical Energy) Natural Gas (Chemical Energy)

Conventional Electrical Generator

Turbine (Mechanical Energy) Alternator (Electrical Energy) Natural Gas (Chemical Energy) Combustion (Thermal Energy)

Bloom offers up to 60%+ electrical efficiency, the highest commercially available.

Convert fuel directly into electricity…without combustion

slide-4
SLIDE 4

Scalable, Flexible, Modular

Fuel Cell

25 W

Stack

1 kW

Module

40 kW

System

200 kW

Solution

200 kW to MW’s

slide-5
SLIDE 5

The Bloom Energy Server: 21st Century Energy Solution

Natural Gas

  • r

Biogas AC Power DC Power Low/No CO2 No NOx or SOx

Deployed in the field for 6 years Validated with blue chip customers 200kW standard design

slide-6
SLIDE 6

Ultra-Low Emissions Profile – No Water

200 400 600 800 1,000 1,200 1,400 1,600 1,800 2,000 CO2 (lb/MWhr)

40% Reduction in CO2

0.5 1 1.5 2 2.5 3 3.5 SOx (lb/Mwhr)

De minimis SOx

0.5 1 1.5 2 2.5 3 3.5 NOx (lb/MWhr) Bloom MA Marginal

Negligible NOx

Source: USEPA eGrid 2010

Bloom Energy Servers require no water during normal operations - only 240 gallons during start up

slide-7
SLIDE 7

Keys to High Reliability

  • Ship / aircraft design strategy
  • Generators in parallel and modular (6 independent power plants)
  • Utilizes UPS-electronics design strategies
  • Chemical reaction without moving parts, low pressure, air cooled
  • Relies on gas grid rather than electric grid

Page 7 | Confidential

slide-8
SLIDE 8

Targeted – Customer or Grid Side of Meter

Page 8

All electric fuel cells do not require a thermal load and can be targeted to improve grid reliability or isolate customers from grid disruptions.

slide-9
SLIDE 9

Preparing for the Future

Fast Charging Vehicles Data Centers

Direct DC Power Source Business Continuity

Uninterruptible Power for Business Processes

slide-10
SLIDE 10

A Growing Customer List

slide-11
SLIDE 11

Improve Incentives for Clean and Reliable DG

  • The digital economy is making electric system reliability more

important every day. Incentive programs should be crafted to encourage both clean energy and reliable energy.

  • All-electric fuel cells can be precisely targeted to improve grid

reliability and can offer uninterruptible power or “grid islanding” capabilities.

  • All-electric fuel cells are competing and winning in other
  • markets. MA has no incentive program in which all all-electric

fuel cells are allowed to compete.

  • All-electric fuel cells should be able to compete for long term

contract and REC programs. Standby rate exemptions and net metering should be available for all clean and reliable DG.

  • The MA “grid modernization” and CT “micro-grid” initiatives are
  • pportunities to add reliability values to incentive programs.