uconn energy conservation
play

UCONN Energy Conservation C.O.R.E Assessment Matrix December 19, - PowerPoint PPT Presentation

UCONN Energy Conservation C.O.R.E Assessment Matrix December 19, 2008 Energy Budget Goals Primary Goal Reduce volatility of gas pricing by increased hedging Currently at near historical low prices Secondary Goals Increase


  1. UCONN Energy Conservation C.O.R.E Assessment Matrix December 19, 2008

  2. Energy Budget Goals • Primary Goal – Reduce volatility of gas pricing by increased hedging – Currently at near historical low prices • Secondary Goals – Increase outreach programs – Reduce average consumption

  3. Energy Expenditures UCONN Storrs Energy Bill Compared to NYMEX $35.00 $10.00 $9.00 $30.00 Energy Spend in Million $$$ $8.00 Gas Price $$$/MMBTU $25.00 $7.00 $6.00 $20.00 $5.00 $15.00 $4.00 UCONN Energy Bill $3.00 $10.00 $2.00 NYMEX Average $5.00 $1.00 $0.00 $0.00 CY99 CY00 CY01 CY02 CY03 CY04 CY05 CY06 CY07 CY08 • CY08 Estimate CY07 $22.32 Million 11,123 Mwh – $ 18.71 Million 1.73 Million MMBTU – 7,354 Mwh CY06 $25.97 Million – 1.81 Million MMBTU 53,648 Mwh 0.79 Million MMBTU (6 mth)

  4. Monitoring Capability • FASER Version 5.0 Software (1999) – Monitors all accounts with energy vendors – Database maintained by Accounts Payable since 2006 by Bruce Gerber/Michael Virone – Updates/Patches required • PowerLogic Square D Software – Monitors on campus sub-meters – Ideally suited for electrical tracking/troubleshooting – Capable of energy use reporting

  5. Monitoring Capability (Continued) • Andover Building Management System – Capable of control, monitoring, and reporting – 150 Buildings can be controlled • Phoenix Control Systems (Lab Hoods) – Used in Labs and Animal Care Facilities where airflow tolerances are critical • CT Water – Monitors campus supplied customers • Metering Program – In process – 30 water meters, minimal users – 20 electrical meters – 10 steam meters

  6. Energy Hogs • Develop lists of Top Ten “Energy Hogs” • Encourage Energy Hog managers to proactively administer conservation efforts • Develop conservation goals addressing issues discovered • Pursue high ROI improvements • Distribute progress reports

  7. CL&P Supplied Energy Hogs July 2007 to Current $18,000.00 $16,000.00 $14,000.00 $12,000.00 $10,000.00 $8,000.00 $6,000.00 Nayden Clinic $4,000.00 $2,000.00 $0.00 SPRING WATER ANIMAL LONGLEY RT. 195 ST MDC Pump OFFICE OF AGRONOMY CAMPUS Celeron Path MANOR TREATMENT ISOLATION BLDG LIGHTS Station Birch SPECIAL SVC PLANT & SOIL SHOPPING FARMS PLANT BARN Rd PLAZA

  8. UCONN Main CL&P Meters $700,000.00 $600,000.00 MAIN CAMPUS DEPOT CAMPUS MAIN $500,000.00 $400,000.00 $300,000.00 $200,000.00 $100,000.00 $0.00 Jul-07 Aug-07 Sep-07 Oct-07 Nov-07 Dec-07 Jan-08 Feb-08 Mar-08 Apr-08 May-08 Jun-08 Jul-08 Aug-08 Sep-08

  9. Sample Monthly Electrical Report Willimantic Well Field UCONN Spring Manor Farms CL&P Electrical FY08-Current $18,000.00 $16,000.00 $14,000.00 $12,000.00 $10,000.00 $8,000.00 $6,000.00 $4,000.00 $2,000.00 $0.00 Jul-07 Aug-07 Sep-07 Oct-07 Nov-07 Dec-07 Jan-08 Feb-08 Mar-08 Apr-08 May-08 Jun-08 Jul-08 Aug-08 Sep-08

  10. CNG Energy Hogs July 2007 to Current $35,000.00 $30,000.00 $25,000.00 $20,000.00 $15,000.00 $10,000.00 $5,000.00 $0.00

  11. Sample Monthly Gas Report Longley Building Natural Gas $18,000.00 $16,000.00 $14,000.00 $12,000.00 $10,000.00 $8,000.00 $6,000.00 $4,000.00 $2,000.00 $0.00 Jul-07 Aug-07 Sep-07 Oct-07 Nov-07 Dec-07 Jan-08 Feb-08 Mar-08 Apr-08 May-08 Jun-08 Jul-08 Aug-08 Sep-08

  12. Converting Gas to Electricity UCONN Central Utility Plant Natural Gas $2,500,000.00 CUP BOILERS COGEN GENERATION COGEN DEMAND $2,000,000.00 $1,500,000.00 $1,000,000.00 $500,000.00 $0.00 Jul-07 Aug-07 Sep-07 Oct-07 Nov-07 Dec-07 Jan-08 Feb-08 Mar-08 Apr-08 May-08 Jun-08 Jul-08 Aug-08 Sep-08

  13. Sample PowerLogic Monthly Report UCONN COGEN Supplied Building Electrical Energy Hogs FY08-Current 2500 2000 Average Power (kw) Demand Peak (kw) 1500 1000 500 0

  14. Conservation Project Types • Lighting – High Efficiency/Low Wattage • VFD – Variable Speed Drive on motors/fans • Occupancy Sensors – Hallways and Stairs • Energy Star Program – Appliances/Equipment • CO2 Sensors- Air change optimization

  15. Previous Conservation Projects Equipment Life Cycle Savings • Biology Physics Building New (2002) • Engineering IT Building New (2003) • Pharmacy Biology New (2005) • North Parking Garage (2006) • South Parking Garage (2006)

  16. New Potential Conservation • • Industry Recruitment/Support Utility Rebate Program – – CCEF - Operational Demonstration Program Connecticut Light & Power - Commercial Energy Efficiency Rebates – New Energy Technology Program – Connecticut Light & Power - Energy Opportunities Efficiency • Leasing/Lease Purchase CCEF - CT Solar Lease Program Program • Property Tax Exemption Property Tax Exemption for – Connecticut Light & Power - Express Rebate Programs Renewable Energy Systems – Connecticut Light & Power - Operation and Maintenance • State Grant Program C Program – CEF - Community Innovations Grant Program • Alternative Fuel and Vehicle Incentives U.S. Department of – CCEF - On-Site Renewable DG Program Energy's Alternative Fuels Data Center – CCEF - Project 150 Initiative • Rules, Regulations & Policies – DPUC - Capital Grants for Customer-Side Distributed • Appliance/Equipment Efficiency Standards Energy Efficiency Resources Standards for Appliances • State Loan Program • Building Energy Code Connecticut Building Energy Code with – CHIF - Energy Conservation Loan Green Building Provisions – DPUC - Low-Interest Loans for Customer-Side Distributed • Contractor Licensing Solar and Wind Contractor Licensing Resources • Energy Standards for Public Buildings Green Building • State Rebate Program Standards for State Facilities – CCEF - Affordable Housing Initiative Solar PV Rebate • Generation Disclosure Fuel Mix and Emissions Disclosure Program • Green Power Purchasing/Aggregation Connecticut - Green – CCEF - Solar PV Rebate Program Power Purchase Plan – Furnace and Boiler Replacement Rebate Program • Net Metering Connecticut - Net Metering • Utility Grant Program The United Illuminating Company - • Energy Conscious Blueprint Grant Program Public Benefits Fund • – RenewablesPortfolio Standard Renewable Portfolio Standard Connecticut Clean Energy Fund – • Connecticut Energy Efficiency Fund Alternative Fuel and Vehicle Policies U.S. Department of Energy's Alternative Fuels Data Center

  17. Building Schedule Reduction Savings Weekend and Holiday Break UCONN Campus Electrical Load 20000 Hourly Average 19000 18000 17000 16000 15000 14000 13000 12000 11000 10000

  18. Building Schedule Reduction Savings Weekend and Holiday Break UCONN Campus Electrical Load 20000 Weekend Hourly Average Weekend 19000 Modified Building Schedule 18000 17000 Kwh Demand 16000 15000 14000 13000 12000 11000 [School In Session 12/01 - 12/12] [School Break 12/12 - 12/22] 10000

  19. Building Schedule Reduction Savings Weekend and Holiday UCONN Campus Steam Use 120 S t 110 e COGEN Hourly Average a 100 m 90 F l 80 o w 70 ( 60 K p 50 p h ) 40

  20. Example Schedule Reductions Breaks & Holidays Percentage Percentage Revised Occupied Total Hours run time of Kwh Monthly Building Name Occupied Hours Reduced Saved on Building’s Reduction Savings Hours AHU/FCU Energy Music Orchestra & 16 10 6 37.5% 40% 1142 $88.19 Library Field House 17 10 7 41.1% 55% 1072 $82.78 Chemistry 17 10 7 41.1% 40% 1800 $139.00 Engineering 16 7 9 43.7% 40% 681 $52.59 & UTEB Student 15 10 5 33.3% 55% 3009 $232.37 Union

  21. Savings Thumb Rule Cooling Thermostat Heating Thermostat

  22. Out Reach Savings Potential Non Automated Lighting Classroom & Office High Tech & Science Assumptions Residential Buildings Buildings Buildings Lighting Load 20% 40% 30% Focused Compliance 25% 25% 25% Example Building South Campus Dorm Torrey Life Science Chemistry Kwh Savings/Month 1700 2300 7800 $$/Mwh @COGEN Cost 10.38 10.38 10.38 Total Savings/Month $ 170.00 $ 230.00 $ 780.00 Annualized Storrs Savings $28,814 $38,980 $132,203

  23. Example Resident Hall Setback 3% Savings Per 1°F (proves Rule of Thumb) December 2008 Kwh Data Average Setback 72°F to 65°F 25% Building Square Thurs. Name Footage Set- Mon. Tues. Weds. Average Delta % Change point Reduced Beard 34,878 462 646 409 326 435 109 -33% Bethune 25,130 419 514 344 254 381 127 -33% Crandall 34,878 258 323 200 147 229 82 -36% Flesche 25,130 171 190 144 119 157 38 -24% French 25,130 256 320 236 192 246 54 -21% Merritt 25,130 181 297 208 147 195 48 -25% Grasso 34,878 638 846 645 505 641 136 -21%

  24. Steam Trap & Line Maintenance Program Potential Savings • 153 Buildings (7M square feet) Supplied • ~5,000 Steam Traps on Campus • Water Make-Up of 33-42 Million Gallons/Year • $2.2 to 3.0 Million/Year Loss – 11-15% of Total Energy Cost • 60% of loss occurs in steam lines & traps • 40% of loss occurs in condensate lines

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.