SLIDE 14 Chemical-Physical Combined Method (CPCM)
14
- A large number of in-house tests using the 3-D consolidation cells were carried out to verify
the effectiveness of CPCM on improvement of MC with higher initial water content.
- Singapore MC with different initial
water content at 2LL, 3LL and 4LL has been used for tests.
- The average Cu value of pure MC
achieved by VP is 21kPa which is used as the reference.
- The Cu values achieved after
CMCP with the selected chemical binders are generally 2 to 3 times
- f that of pure MC under VP only.
- It proves that CPCM can achieve
much higher strength than what vacuum preloading does.
the initial/final water contents have big differences, the final strength looks quite closer.
- FIG. 5a. Testing results of Singapore MC by CPCM
Note: 1: MC(2LL); 2: MC(3LL); 3: MC(4LL); 4: MC(2LL)+4%331E(6-M soaking); 5: MC(2LL)+4%331E+20%IBA(6-M soaking); 6: MC(4LL)+8%331D(1-M soaking); 7: MC(4LL)+8%331E(7-M soaking); 8: MC(4LL)+8%331H(1-M soaking); 9: MC(4LL)+4%331H; 10: MC(3LL)+4%331H; 11: Column, MC(200%)+2%SS-331H(1-M soaking); 12: Column, MC(270%)+2%SS-331H(1-M soaking); 13: Column, MC(270%)+4%SS-331H(1-M soaking).
10 20 30 40 50 60 70 80
0.0 10.0 20.0 30.0 40.0 50.0 60.0 70.0 80.0
40 66 92 118 144 170
Cu (kPa) Final water content, wf (%)
1 2 3 4 5 6 7 8 9 10 11 12 13 Pv = 95kPa, LL=79% 4%cement MC (2LL, 3LL, 4LL)
5 10 15 20 25 30 35 40
2%SS-331 4%SS-331 8%SS-331 MC-IBA matrix
Estimated Ultimate Bearing Capacity (t/m2)