SELF-CLEARING IMPLANTABLE BIOSENSORS FOR NEURODEGENERATION RESEARCH - - PowerPoint PPT Presentation

self clearing implantable biosensors for
SMART_READER_LITE
LIVE PREVIEW

SELF-CLEARING IMPLANTABLE BIOSENSORS FOR NEURODEGENERATION RESEARCH - - PowerPoint PPT Presentation

Towards SELF-CLEARING IMPLANTABLE BIOSENSORS FOR NEURODEGENERATION RESEARCH Hyowon Hugh Lee Assistant Professor Weldon School of Biomedical Engineering Purdue University Acknowledgements first Grad Students: Qi Yang Hyunsu Park


slide-1
SLIDE 1

SELF-CLEARING IMPLANTABLE BIOSENSORS FOR NEURODEGENERATION RESEARCH

Hyowon “Hugh” Lee

Assistant Professor Weldon School of Biomedical Engineering Purdue University

Towards

slide-2
SLIDE 2

Acknowledgements first…

Grad Students: Qi Yang Hyunsu Park Tran Nguyen James Nolan Angel Enriquez Haesoo Moon Jongcheon Lim Jian Xu – Postdoc Jinjia Xu – Postdoc Collaborators: Riyi Shi, Herman Sintim, Bryan Boudouris

slide-3
SLIDE 3

State-of-the-art in implantable sensors

3

LICOX Brain Tissue Oxygenation Monitor Integration Neurosciences: 7-14 days G6, Dexcom CGM: 10 days Eversense, Senseonics: 90 days Abbott Freestyle Libre CGM: 14 days

slide-4
SLIDE 4

Spinal cord injury statistics and facts

347,000 in the US

Annual national cost Demographic Long term complication

$9.7 billions

75 years 0 years

29-42 2.5 millions worldwide

Spinal cord neuron Reactive astrocyte Immune system cell Astrocyte Resting microglia Apotosis Cellular debris Exctitotoxicity and

  • xidative damage

Normal spinal cord Primary injury

itoto

Secondary injury

Demyelination Severe axon

Activated microglia

slide-5
SLIDE 5

Nanocomposite-based flexible biosensor

5 50 µm 100 µm

Nguyen et al., Biosens. Bioelectron. 2019

slide-6
SLIDE 6

Fabrication, in vitro, ex vivo tests

a.

6

Time (s)

1200 1300 1400 1500 1600 1700 1800

Current Density (nA/mm2)

200 400 600 800 1000 1200 1400 1600

50 µM 50 µM 50 µM 200 µM 200 µM PtNPs-MWCNT-PEDOT:PSS-Nafjon-GluOx MWCNT-PEDOT:PSS-Nafjon-GluOx PEDOT:PSS-Nafjon-GluOx

c.

Device in the spinal cord

Nguyen et al., Biosens. Bioelectron. 2019

slide-7
SLIDE 7

Reliability issues à opportunity!

Prevent & Disrupt Biofouling! Strategy: Use Active and Passive Approaches

slide-8
SLIDE 8

Active anti-biofouling strategy

𝜚 = 𝑊

$𝑁𝐼𝑡𝑗𝑜 * + − 𝜚 /k/012

𝑙456$ = 𝐹𝐽 𝑀 , 𝐽 = 𝑥𝑢= 12

𝜚

H = 0 H = 16kA/m

Dynamic responses of microactuators

*

*

Moving forward Moving backwards

Large amplitude actuation for self-cleaning

Removing blood clot obstruction

Yang et al., S&A:B, 2018

slide-9
SLIDE 9

Towards self-clearing biosensors

Unpublished

slide-10
SLIDE 10

Questions?