1
Reducing Cross Infection Risk Through Single Use Human Waste System - - PowerPoint PPT Presentation
Reducing Cross Infection Risk Through Single Use Human Waste System - - PowerPoint PPT Presentation
Reducing Cross Infection Risk Through Single Use Human Waste System 1 Plastic and Stainless Steel Pans and Bottles - Washers $$$$ - Difficult to maintain and clean - Clear cross infection risk - Risk of Bacteria being presented to patient -
2
Plastic and Stainless Steel Pans and Bottles
- Washers $$$$
- Difficult to maintain and clean
- Clear cross infection risk
- Risk of Bacteria being presented to patient
- High Water and Energy use
Extensive maintenance and testing regulations
3
The Single Use System
- Reduced cross infection
- Combats contamination
- Fast, efficient waste disposal
- Minimum human contact
- Cost efficient
- Energy efficient
- Saves Nursing Time
4
Energy Usage comparison based on estimated annual usage of 10,000 pulp items Water Usage Comparison based on 1.5 Pulp items per Patient Per Day, with 1 x Macerator (4 x Pulp items per cycle) serving 20 beds
Haigh Quattro Haigh Quattro
5
UK Sales (Comparison)
In the UK (pop ~70M) there are approximately:
- 20,000 Macerators installed in 95% of Hospitals
- 1 Macerator per 20 Patient Beds
- 1.5 Pulp Items per Patient Per Day
- 1200 Macerator Sales Per Year
SOLO extending the Disposable System into:
- X-Ray departments
- Isolation Wards
- Clinics
- Private Rooms
6
The importance of Brand
The Haigh Solution.
7
Haigh Macerator Range
8
The Quattro Solution
- Easy to operate, maintain and clean
- Fast (82s)
- Reliable
- Quiet
- Small footprint
- Automated Start
- Foot Pedal Opening and Close (touchless)
- Anti-Microbial
- Configurable drain settings
9
The Quattro Vanguard
- Failsafe automatic open and close
- Superfine Maceration
- Controlled Discharge
- Proven rinse protect cycle
- Reduced operation noise
- Night mode
10
The Quattro Vanguard
- Failsafe automatic open and close
Designed and built lid mechanism to withstand the heavy use in busy wards. So if there is an obstruction, the lid will sense it and open again. If closed manually, the machine will also sense and gently drop the lid.
- Superfine Maceration
We’ve developed a high precision impeller with new swept blades that spin at 1500rpm. This means they produce the finest pulp confetti of any macerator, that will flow easily through your drains.
- Controlled Discharge
We’ve made the tolerance on our controlled discharge system even tighter. So now Quattro won’t let anything larger than 5mm enter the drain.
11
The Quattro Vanguard
- Proven rinse protect cycle
At the end of every cycle Quattro injects a micro dose of TECcare CONTROL that kills all related HCAI pathogens and protects the machine for up to 24 hours. Haigh is the only company to have the effectiveness of its macerators’ infection control confirmed by independent laboratory tests.
- Reduced operation noise
All these changes mean Quattro is now the quietest macerator on the market
- Introducing night mode
All these changes mean Quattro is now the quietest macerator on the market – only 54 dB in night mode
12
The Quattro Excel
- Failsafe automatic open and close
- Superfine Maceration
- Controlled Discharge
- Proven rinse protect cycle
- Reduced operation noise
- Aero-Jet Powered Premium Flow
- Aero-jet foam flush
- All-round protection
- One-shot foam flush
13
The Quattro Excel
- Aero-Jet Powered Premium Flow
Our engineers have taken our unique patented Premium Flow action further with new aero-jet powered Premium Flow. This adds a jet of air to the discharged pulp, making it more buoyant and less dense so it flows more freely.
- Aero-jet foam flush
Quattro’s patented aero-jet powered Premium Flow cleans your drains as well as keeping them flowing
- freely. This is because the jet of air causes TECcare CONTROL to foam killing bacteria as it flows through
the drainpipe.
- All-round protection
Our engineers have developed a unique wick system that carries TECcare’s protection to all the internal areas of your macerator, not just the drum One-shot foam flush
14
Disinfectant Products
Macerator Disinfectant
Description: TECcare CONTROL is a safe, non-corrosive, broad spectrum, high level disinfectant that
- ffers cost effective single stage cleaning and
- disinfection. It has been proven to reduce the
risks posed by microbes to their lowest practical levels within the hopper of a Haigh Quattro.
Maceratable Disinfectant Wipes & Spray
Description: In addition to disinfecting the inside of the macerator, ancillary items are available to clean the outside. There are maceratable disinfectant wipes and disinfectant spray – both of which offer single stage cleaning and disinfection, highly effective on bacteria, fungi/yeasts and viruses
15
Haigh Controlled Discharge
Multiple Small Outlets to Drainage. Foreign objects blocks at source Particle size 2mm to 5mm Single large outlet to drainage system. Foreign objects flushed into drains Un-maceratable items can block drains
5mm Slots 5mm Slots
Dependable...
Manufacturers of macerators for over 50 years, with dedicated and technologically advanced manufacturing facilities and a committed service team, the Haigh Quattro provides an unrivalled product package.
50+
Years Manufacturing
Dedicated
design and manufacture
Hygienic...
Designed with infection control in mind, smooth, accessible and easily cleaned surfaces, enhanced with silver-ion antibacterial protection, make the Quattro the most hygienic pulp macerator available.
Silver-ion
Antibacterial Protection Built-In
Efficient...
19%
Less Energy*
*than competitive product
29%
Less Water*
Reduced energy and water usage by the use of efficient motors and optimised cycles makes Quattro cheaper to run in these cost conscious times.
Compact...
32%
Smaller*
*than nearest competitor
Featuring full four pulp item capacity for the busiest
- f wards, Quattro’s compact footprint provides
valuable additional space in the dirty utility (sluice) room.
Lower...
20%
Lower Loading*
*than nearest competitor
Quattro’s low ergonomic loading height improves loading by reducing the chances of spillage and splashing.
22
Typical Sluice/Dirty Utility Room with Pulp and Support Products
23
- Human Faecal Waste
- Any type of Pulp / Paper
- Disposable Item
- All macerator friendly wipes
Not for:
- Plastics (will not function)
- Blood (Hazardous to Health)
- Sharps / Needles / Syringes
Solves high percentage of Waste Disposal Disposal options…
24
The importance of Brand