Radio waves are all around us: TV Radio Mobile phones Wi-Fi, - - PowerPoint PPT Presentation

radio waves are all around us tv radio mobile phones wi
SMART_READER_LITE
LIVE PREVIEW

Radio waves are all around us: TV Radio Mobile phones Wi-Fi, - - PowerPoint PPT Presentation

RADIO WAVES Radio waves are all around us: TV Radio Mobile phones Wi-Fi, They propagate all around us and go through almost any material APLICATION OF RADIO WAVES(RW) Medical: dermatology, gynecology, surgery, etc.


slide-1
SLIDE 1

RADIO WAVES  Radio waves are all around us:  TV  Radio  Mobile phones  Wi-Fi,  They propagate all around us and go through almost

any material

slide-2
SLIDE 2

APLICATION OF RADIO WAVES(RW)

 Medical: dermatology, gynecology,

surgery, etc.

 Aesthetics: non-invasive face and body

treatments (RW skin tightening, body shaping)

slide-3
SLIDE 3

RADIO WAVE APPLICATION IN AESTHETICS

SKIN TIGHTENING - ST AND BODY SHAPING - BS

slide-4
SLIDE 4

TYPES OF RW TREATMENTS

 Monopolar – body shaping, deep penetration, waves go through whole body heating

the tissue, this process affects on fat molecule dissolving and blood circulation. Current goes through whole body, from probe (HandPiece – HP) to neutral electrode, there is no way to predict current flow path through the body. Not safe

  • way. Disputable effects.

 Bipolar – depending on frequency and electrode distance, body shaping or skin

tightening (effect on collagen fibers or fat tissue cells. Safe, efficient and controlled method with results which are repeatable.

slide-5
SLIDE 5

Combined platform for BS i ST!

slide-6
SLIDE 6

RW SKIN TIGHTENING (ST)  Mostly used in aesthetics and cosmetology  Leads to natural regeneration of collagen  Non-invasive, painless and safe method  No consumables – fast ROI

slide-7
SLIDE 7

RW SKIN TIGHTENING (ST)

 Bipolar technology  Precisely controlled depth of penetration  Precise effect on collagen layer with maximal energy density  Active treatment with no undesired effects  No additional costs  Safe, constant and unique results

slide-8
SLIDE 8

RW BODY SHAPING (BS)  Bipolar technology  Precisely controlled depth of penetration and applied energy  Aimed effect on adipose tissue layer of hypoderm  For best results stimulation of lymph system should also be done

(device for automated lymph drainage)

 Safe, unique and efficient treatment with no consumables

slide-9
SLIDE 9

BIOMEDICAL FOUNDATION

 RW below 3MHz cause movement of charged particles (water molecules and

ions) through the tissue in direction of RW (can cause electrollite disbalance in body)

 RW between 3MHz and 5MHz cause molecule vibrations  Electromagnetic field with frequency above 5MHz cause rotation of water

molecules

 Depth of penetration and heat effect depends on electrode distance between

electrodes, frequency, applied RW technology, applied power and electrical features

  • f the tissue
slide-10
SLIDE 10

BIOMEDICAL FOUNDATION

Epidermis Dermis Hypodermis IPL, lasers NIR lasers, NIR pulse light Bipolar

Monopolar Bipolar

Monopolar Monopolar Monopolar

 Depth of penetration

slide-11
SLIDE 11

BIOMEDICAL FOUNDATION  RW devices generate controllable RW energy  Around 75% of human body is made of water  Water molecules are functional dipoles (positive – oxygen, negative

– hydrogen)

 Polarized molecules placed in electrical field have orientation

slide-12
SLIDE 12

BIOMEDICAL FOUNDATION

 ShapeUp! Device works on 4MHz frequency – electromagnetic field

changes direction 4.000.000 times per second

 Water molecules vibrate, causing heat and temperature increase in tissue,

their friction (between molecules) causes therapeutic effect

slide-13
SLIDE 13

BIOMEDICAL FOUNDATION

 4MHz frequency is safest choice for bipolar RW  Cooling is not necessary, and in the same time needed power is available for the

maximal effect (max. 50W) and optimal results

 Energy penetrates into skin up to 6mm (for ST) or 20mm (for BS) before it is fully

absorbed by water molecules

 Maximal energy density is at 2 to 4mm for ST and 5 to 15 for BS (measured from the

surface of HP)

slide-14
SLIDE 14

BIOMEDICAL FOUNDATION

 Shape of the HP enables equal energy distribution and constant depth

  • f penetration on the whole active area of HP

, without regard of direction

  • f HP movement

 Equal Energy Distribution (EED) = minimal possibility of adverse

effects + stable and unique results

slide-15
SLIDE 15

BIOMEDICAL FOUNDATION

  • RING ELECTRODE eneables EED and constant depth of penetration
slide-16
SLIDE 16

BIOMEDICAL FOUNDATION

 Study conducted on 35 healthy women, 15 days after treatment

Before treatment After treatment

slide-17
SLIDE 17

BIOMEDICAL FOUNDATION– BS

 Energy generated with BS HP penetrates up to 20mm into body before it is

completely absorbed in water molecules

 Since fat tissue has highest impedance for RW, this RW energy transforms into heat  Heating fat tissue increases its potential energy causing triglyceride and diglyceride,

monoglyceride and free fat acids, which are, in contrast with lipids stored in adipocites, in liquid state

 Liquid fat is released in intercellular space causing fat cell shrinkage

slide-18
SLIDE 18

COUNTERINDICATIONS

 Malignancy  Pregnancy  Skin irritation  High blood pressure  Blood coagulation disorders  Active or recent use of accutane

slide-19
SLIDE 19

COUNTERINDICATIONS

 Pacemaker, defibrilator or other internal electrical device  Autoimmune disease  Multisystem diseases  Tooth implants  Fillers and botox (RW treatment speeds up dissolvment)

slide-20
SLIDE 20

SPECIAL ATTENTION

 Smokers  Alcohol, tea and coffee  Metal tooth implants  Recent surgical interventions  Current drug therapy

slide-21
SLIDE 21

CHOOSING THE CLIENTS

 Potential client is a healthy person with active aesthetic issues – skin

laxity, wrinkles, localized fat tissue and cellulite

 Client needs to be prepared for the treatment, with increased, balanced

fluid intake

slide-22
SLIDE 22

PROTOCOL

 For best and longterm results it is recommended to repeat 4 to 6 treatments once

a month for ST or twice a month for BS

 Treatment is dynamic, done by smooth circular movements, covering the whole area  There are two treatment phases:

I Pre-therapy- (until reaching tissue temperature up to 40 ° C) II Therapy - (depending of set power longer or shorter time treatment) Goal is to “deliver enough amount of energy into the treated area)

slide-23
SLIDE 23

TREATMENT PHASES

Pre-therapeutic phase Therapeutic phase

Time T°C

38°C 43°C

slide-24
SLIDE 24

PROTOCOL

 After RW treatment, there is light erythema and edema, which should disappear

after a few hours, rarely after a day or two

 Tissue is warm, smooth, firm and slightly more sensitive than after the treatment  Best results are expected after 2 weeks (BS) or 4 weeks (ST) after the treatment  ST treatmant should be repeated 3-6 times in intervals of 3-4 weeks  BS treatmant should be repeated 2-6 times in intervals of 2-3 weeks

slide-25
SLIDE 25

PROTOKOL

 Client should be prepared for the treatment by increased hydration

(water consumption) at least 3 days prior and 3 days after the treatment

 No special need is required after the treatment, on the treated area

thermal water or hydration cream for calming of the skin, or Aloe vera gel eg.

slide-26
SLIDE 26

APPLICATION EXAMPLE

slide-27
SLIDE 27

APPLICATION EXAMPLE

slide-28
SLIDE 28

RESULTS

slide-29
SLIDE 29

RESULTS

1st

slide-30
SLIDE 30

RESULTS

3Th

slide-31
SLIDE 31

RESULTS

3Th

slide-32
SLIDE 32

RESULTS

3Th

slide-33
SLIDE 33

RESULTS

2nd

slide-34
SLIDE 34

RESULTS

1st

slide-35
SLIDE 35

RESULTS

1st

slide-36
SLIDE 36

RESULTS

1st

slide-37
SLIDE 37

RESULTS

1st

slide-38
SLIDE 38

RESULTS

1st

slide-39
SLIDE 39

RESULTS

2nd

slide-40
SLIDE 40

RESULTS

slide-41
SLIDE 41

RESULTS