gdchillers.com info@gdchillers.com 1.800.555.0973 Meeting Overview Introductions Chiller sizing Selection/customization Components Maintenance Installation Piping gdchillers.com info@gdchillers.com


slide-1
SLIDE 1

gdchillers.com info@gdchillers.com 1.800.555.0973

slide-2
SLIDE 2

gdchillers.com info@gdchillers.com 1.800.555.0973

Meeting Overview

  • Introductions
  • Chiller sizing
  • Selection/customization
  • Components
  • Maintenance
  • Installation
  • Piping
slide-3
SLIDE 3

25 Years Experience in the Brewery Industry

slide-4
SLIDE 4

gdchillers.com info@gdchillers.com 1.800.555.0973

About us

  • Founded in 1993 in Eugene, Oregon
  • Started with Pacific Northwest winery & craft brewing booms
  • Now nationally renowned, with chillers in all 50 states and abroad
  • Privately held company
slide-5
SLIDE 5

gdchillers.com info@gdchillers.com 1.800.555.0973

About us

slide-6
SLIDE 6

CHILLER SIZING & SELECTION

Andy Backer– VP of Sales

slide-7
SLIDE 7

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Sizing Considerations

  • Brew House / Batch Size

→How many batches: Daily? Weekly?

  • CLT
  • Heat Exchangers
slide-8
SLIDE 8

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Sizing Considerations

  • 2 Stage Heat Exchanger
  • City Water Temperatures
  • Wort Knockout time
slide-9
SLIDE 9

gdchillers.com info@gdchillers.com 1.800.555.0973

Heat Exchanger Offerings

slide-10
SLIDE 10

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Sizing Considerations

Fermenters

  • Quantity
  • Size

Brite Tanks:

  • Quantity
  • Size
slide-11
SLIDE 11

gdchillers.com info@gdchillers.com 1.800.555.0973

Additional Sizing Considerations

  • Worst case scenario for city water supply
  • Ambient Temperatures
  • Walk-in cooler
  • Lagering
slide-12
SLIDE 12

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Selection

  • Thinking about the future:

→Do you have current plans for growth? →What is your total build out scenarios?

  • Chiller location matters
  • Is the chiller being tied into an existing chiller/system/reservoir?

Single Stage Chillers Multi Stage Chillers Vertical Air Chillers

slide-13
SLIDE 13

gdchillers.com info@gdchillers.com 1.800.555.0973

Common Customization

  • Remote Condenser
  • Remote Pump & Reservoir Stand
  • Cooling Tower / Onsite Chiller Build
slide-14
SLIDE 14

CHILLER COMPONENTS AND MAINTENANCE

John McCoy– General Manager

slide-15
SLIDE 15

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Components

  • 1. Fully coated steel frame
  • 2. Fully coated aluminum housing
  • 3. Fully insulated oversize stainless steel reservoir
  • 4. Various types of compressors depending on application
  • 5. Air cooled or water cooled condensers
  • 6. Brazed plate heat exchangers
  • 7. Adjustable bypass valves
  • 8. Pumps & variable frequency drives
slide-16
SLIDE 16

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Components

  • 1. Fully coated steel frame
  • 2. Fully coated aluminum housing
  • 3. Fully insulated oversize stainless steel reservoir
  • 4. Various types of compressors depending on application
  • 5. Air cooled or water cooled condensers
  • 6. Brazed plate heat exchangers
  • 7. Adjustable bypass valves
  • 8. Pumps & variable frequency drives

2 1 3

slide-17
SLIDE 17

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Components

  • 1. Fully coated steel frame
  • 2. Fully coated aluminum housing
  • 3. Fully insulated oversize stainless steel reservoir
  • 4. Various types of compressors depending on application
  • 5. Air cooled or water cooled condensers
  • 6. Brazed plate heat exchangers
  • 7. Adjustable bypass valves
  • 8. Pumps & variable frequency drives

4

slide-18
SLIDE 18

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Components

  • 1. Fully coated steel frame
  • 2. Fully coated aluminum housing
  • 3. Fully insulated oversize stainless steel reservoir
  • 4. Various types of compressors depending on application
  • 5. Air cooled or water cooled condensers
  • 6. Brazed plate heat exchangers
  • 7. Adjustable bypass valves
  • 8. Pumps & variable frequency drives

5 6

slide-19
SLIDE 19

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Components

  • 1. Fully coated steel frame
  • 2. Fully coated aluminum housing
  • 3. Fully insulated oversize stainless steel reservoir
  • 4. Various types of compressors depending on application
  • 5. Air cooled or water cooled condensers
  • 6. Brazed plate heat exchangers
  • 7. Adjustable bypass valves
  • 8. Pumps & variable frequency drives

7 8

slide-20
SLIDE 20

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Components

Electrical components

  • Non-proprietary ETL listed electrical components
  • Phase & Voltage monitor as standard
  • Multiple safety devices as standard
  • Single point electrical connection
  • Micro processing controls as standard
slide-21
SLIDE 21

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Components

slide-22
SLIDE 22

gdchillers.com info@gdchillers.com 1.800.555.0973

Chiller Maintenance

  • Glycol Level
  • Glycol Mixture
  • Condenser cleanliness
  • Periodic/annual maintenance schedule
  • Reputable refrigeration contractor
  • 24/7 support
slide-23
SLIDE 23

CHILLER INSTALLATION

Seth McEldowney – Senior Project Manager

slide-24
SLIDE 24

Chiller Installation

  • Placement & Rigging
slide-25
SLIDE 25

Electrical and Process Glycol Connections

slide-26
SLIDE 26

Breakside Brewing – PI- PVC80, Cu Von Ebert – GF CoolFit+, Cu

  • GF CoolFit+
  • PI- PVC80
  • Welded SS
  • Copper

Piping Materials

slide-27
SLIDE 27

Stony Creek Brewing – PI- PVC80 Ninkasi Brewing – GD CoolFit+

Piping Materials

slide-28
SLIDE 28

Reverse-Return Piping

  • Line Sizing
  • Flow Rate
  • Velocity
slide-29
SLIDE 29

Great Notion Brewing Pfriem Brewing

Pipe Racking and Support

slide-30
SLIDE 30

Tank and Equipment Piping

  • Parallel vs In Series
slide-31
SLIDE 31

Tank and Equipment Piping

  • Fan Coils

Breakside Brewing

slide-32
SLIDE 32

Flex Connections Heat Exchanger Piping

Tank and Equipment Piping

slide-33
SLIDE 33

Strainers and Backflow Prevention

slide-34
SLIDE 34

Strainers, Backflow Prevention, and Air Vents

slide-35
SLIDE 35

Pressure and Flow Regulation

  • Process Bypass Loops
slide-36
SLIDE 36

Pressure and Flow Regulation

  • Pressure regulating valves
  • VFDs
slide-37
SLIDE 37

Temperature and Flow Controls

slide-38
SLIDE 38

Field refractometer

System Commissioning

  • 3ph motor rotation
  • Pressure testing
  • Flushing
  • Glycol mixing
  • System testing
slide-39
SLIDE 39

gdchillers.com info@gdchillers.com 1.800.555.0973

Committed to Cold

  • 24/7 Support
  • No proprietary parts
  • Install support included with every chiller
  • Piping design and consultation free of charge

Watch how we build

https://gdchillers.com/applications/breweries/

slide-40
SLIDE 40

Q&A