SLIDE 11 EXIST ING WO O D SING LE DO UBLE-HUNG WINDO W WIT H MUNT IN
SC ALE : 1/ 2" = 1'-0"
EXIST ING ALUM. SING LE DO UBLE-HUNG WINDO W WIT HO UT MUNT IN
SC ALE : 1/ 2" = 1'-0"
EXIST ING WO O D SING LE DO UBLE-HUNG WINDO W WIT H MUNT IN
SC ALE : 1/ 2" = 1'-0"
EXIST ING ALUM. SING LE DO UBLE-HUNG WINDO W WIT HO UT MUNT IN
SC ALE : 1/ 2" = 1'-0"
EXIST ING WO O D SING LE DO UBLE-HUNG WINDO W WIT H MUNT IN
SC ALE : 1/ 2" = 1'-0"
EXIST ING WO O D SING LE DO UBLE - HUNG WINDO W
SC ALE : 1/ 2" = 1'-0"
± 1'-0" ± 4'-6" ± 1'-10" ± 4'-7" ± 4'-6" ± 4'-7" ± 4'-6" ± 3'-0" ± 5'-7" ± 3'-0" ± 5'-7"
SC ALE : 1/ 2" = 1'-0"
EXIST ING ALUM. SING LE DO UBLE-HUNG WINDO W WIT H MUNT IN
± 3'-0" ± 4'-0"
A B C D E F G
± 4'-0" ± 8" ± 2'-5" ± 4'-6" ± 4'-0" ± 2'-5" ± 1'-6" ± 4'-0" ± 4'-3" ± 2'-5" ± 4'-3" ± 2'-5" ± 4'-0" ± 2'-7" ± 4'-11" ± 3'-0" ± 2'-5" ± 4'-8" ± 3'-0" ± 2'-7" ± 3'-7" ± 2'-1"
SC ALE : 1/ 2" = 1'-0"
EXIST ING ALUM. SING LE DO UBLE-HUNG WINDO W WIT H MUNT IN
H
± 3'-0" ± 1'-7" ± 5'-7" ± 4'-11" ± 3'-0"
1 2 3 6 7 8 9 10 11 12 1 2 3 4 1 2 3 4 4 13 16 18 19 5
LPC -012 LPC -012 LPC -012 LPC -012 LPC -012 LPC -012 LPC -012 LPC -012 LPC -012
5
LPC -012 LPC -012 LPC -012 LPC -012 LPC -012
14
LPC -013 LPC -013 LPC -013 LPC -013 LPC -013 LPC -012 LPC -012 LPC -012 LPC -012
17
LPC -014 LPC -014 LPC -014 LPC -014
16 18 19 17
LPC -014 LPC -014 LPC -014 LPC -014
16 18 17
LPC -014 LPC -014 LPC -014
19
LPC -014
SIM.
EXIST ING ALUM. DO UBLE DO UBLE-HUNG WINDO W WIT H MUNT IN
SC ALE : 1/ 2" = 1'-0"
± 5'-9" ± 5'-7"
EXIST ING ALUM. SING LE FIXED WINDO W
SC ALE : 1/ 2" = 1'-0"
± 3'-4" ± 5'-7"
EXIST ING ALUM. DO UBLE FIXED WINDO W
SC ALE : 1/ 2" = 1'-0"
± 5'-9" ± 5'-7"
M L N
± 2'-9" ± 5'-0" ± 4'-11" ± 2'-1" ± 2'-1" ± 5" ± 2'-11" ± 4'-10" ± 2'-2" ± 2'-2" ± 3'-0" ± 5'-7" ± 2'-8" ± 4'-0" ± 11"
EXIST ING ALUM FIXED WINDO W
SC ALE : 1/ 2" = 1'-0"
O
18 19 16
LPC -014
17
LPC -014 LPC -014
21
LPC -014 LPC -014
20
LPC -014
22
LPC -014
24
LPC -014
23
LPC -014
25
LPC -014
22
LPC -014
24
LPC -014
23
LPC -014
23 24 22
LPC -014 LPC -014 LPC -014
EXIST ING ALUM. T RIPLE DO UBLE-HUNG WINDO W
SC ALE : 1/ 2" = 1'-0"
EXIST ING ALUM. T RIPLE DO UBLE-HUNG WINDO W WIT H T RANSO M
SC ALE : 1/ 2" = 1'-0" C O RRUG AT ED MET AL PANEL T O REMAI N
± 7'-9" ± 7 6 ± 7'-9" ± 8'-6"
FI XED FI XED
A/ C
P Q
± 1'-3" ± 4'-11" ± 3'-2" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 7'-7" ± 4'-6"
C O RRUG AT ED MET AL PANEL T O REMAI N C O RRUG AT ED MET AL PANEL T O REMAI N C O RRUG AT ED MET AL PANEL T O REMAI N
27 28 29 31 32 26 29 31 32 28 30
LPC -014 LPC -014 LPC -014 LPC -014 LPC -014 LPC -014
35
LPC -014 LPC -014 LPC -014 LPC -014 LPC -014 LPC -014
EXIST ING ALUM. DO UBLE DO UBLE-HUNG WINDO W WIT HO UT MUNT IN
SC ALE : 1/ 2" = 1'-0"
EXIST ING WO O D DO UBLE DO UBLE-HUNG WINDO W WIT H MUNT IN
SC ALE : 1/ 2" = 1'-0"
± 1'-10" ± 8" ± 1'-10" ± 4'-6" ± 5'-9" ± 5'-7"
J K
± 3'-10" ± 5'-3" ± 2'-5" ± 4'-11" ± 2'-1" ± 2'-1" ± 5" ± 2'-11"
10 11 12 13 15 21 16 17 18 19 14
LPC -013 LPC -013 LPC -013 LPC -013 LPC -013 LPC -013 LPC -014 LPC -014 LPC -014 LPC -014 LPC -014
EXIST ING ALUM. T RIPLE FIXED/ DO UBLE-HUNG WINDO W
SC ALE : 1/ 2" = 1'-0"
± 7'-9" ± 5'-10"
FI XED FI XED
R
± 2'-1" ± 2'-1" ± 2'-1" ± 4'-11" ± 3'-2"
17 23 22
LPC -014
16
LPC -014
24
LPC -014
28
LPC -014 LPC -014 LPC -014
18
LPC -014
EXIST ING ALUM. Q UADRUPLE DO UBLE-HUNG WINDO W
SC ALE : 1/ 2" = 1'-0"
EXIST ING ALUM. Q UADRUPLE FIXED/ DO UBLE-HUNG WINDO W
SC ALE : 1/ 2" = 1'-0"
A/ C
EXIST ING ALUM. Q UADRUPLE FIXED/ DO UBLE-HUNG WINDO W
SC ALE : 1/ 2" = 1'-0"
FI XED
± 12 -4 ± 12'-4" ± 10'-4" ± 10'-4" ± 10'-4" ± 13'-4"
FI XED FI XED FI XED FI XED FI XED FI XED FI XED
T U V
± 12'-5" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 11'-5" ± 3'-5" ± 3'-8" ± 2'-1" ± 2'-1" ± 2'-1" ± 2'-1" ± 11'-5" ± 3'-5"
C O RRUG AT ED MET AL PANEL T O REMAI N C O RRUG AT ED MET AL PANEL T O REMAI N C O RRUG AT ED MET AL PANEL T O REMAI N C O RRUG AT ED MET AL PANEL T O REMAI N
30 28 31 32 29 37 22 28 31 32 29 27
LPC -015 LPC -015 LPC -015 LPC -015 LPC -015 LPC -015 LPC -015 LPC -015 LPC -015 LPC -015 LPC -015 LPC -015 LPC -015
22
LPC -015
24 25 23
LPC -015 LPC -015 LPC -015
27 28
LPC -015
± 10'-4" ± 13'-4"
FI XED FI XED FI XED FI XED FI XED
± 2'-11" ± 3'-0" ± 2'-11" ± 12'-5"
C O RRUG AT ED MET AL PANEL T O REMAI N
EXIST ING ALUM. T RIPLE FIXED/ DO UBLE-HUNG WNIDO W
S
RELAT I VE SC ALE : 1/ 2" = 1'-0"
35 36 26 33 28 32
LPC -015 LPC -015
23
LPC -014 LPC -015 LPC -015 LPC -015 LPC -015
30
LPC -015
ENG INEERING & ARC HIT EC T URE, DPC
T
- EL. (212) 675-8844 / FAX (212) 691-7972
159 WEST 25T H ST REET NEW YO RK, NY 10001
BUILDING INFO RMAT IO N BLO C K: LO T : MAP: ZO NING DIST RIC T :
LANDMARK:
N
SIT E PLAN
WINDO W REPLAC EMENT MAST ER PLAN 39 WEST 67T H ST REET NEW YO RK, NY 10023 DO C KET # 16-2263 UPPER WEST SIDE-C ENT RAL PARK HIST O RIC DIST RIC T NO VEMBER 10, 2016
15
50' 100.42'
WEST 67T H ST REET WEST 68T H ST REET C O LUMBUS AVENUE C ENT RAL PARK WEST 39
±160'
1120 7 8C R8 YES EXIST ING WINDO W ELEVAT IO NS M140305
L PC - 010
PRIMARY FACADE PRIMARY FACADE