Panduit IA UPS Benefits for Zone Networks 4/15/2014 2 Panduit IA - - PowerPoint PPT Presentation

1 Panduit IA UPS Benefits for Zone Networks 4/15/2014 2 Panduit IA UPS Benefits for Zone Networks Improved availability Saves minutes of switch restart time after brief power interruptions Lower risk of downtime No Battery


slide-1
SLIDE 1

4/15/2014

Panduit IA UPS Benefits for Zone Networks

1

slide-2
SLIDE 2

Panduit IA UPS Benefits for Zone Networks

2

  • Improved availability

– Saves minutes of switch restart time after brief power interruptions

  • Lower risk of downtime

– No Battery eliminates the #1 cause of UPS failures – Maintenance-free removes dependency on preventative maintenance

Top root causes of downtime cited by data center professionals. Totals exceed 100 percent because data center professionals cited multiple root- causes over a period of two years.

slide-3
SLIDE 3

Panduit IA UPS Benefits for Zone Networks

3

  • Lower Cost of Ownership

– Maintenance-free saves time and costs of battery inspections, testing, replacement and disposal – Longer life, up to 20 years, with less derating at high temperatures

slide-4
SLIDE 4

Panduit IA UPS Benefits for Zone Networks

4

  • Improved Device Management

– No proprietary software to download, install, configure, learn and support – No need to “visit” each device with a laptop to check health – Remote management from office, plant floor or mobile devices – Multiple device management – Plug-and-play on FactoryTalk* networks

  • Predictive Monitoring

– Hold Time based on actual load consumption, whether in primary or secondary power supply path – “Life Time” remaining to 80% of original capacity, integrates temperature variations over time

*FactoryTalk is registered by Rockwell Automation in the Patent and Trademark Office of the United States.

slide-5
SLIDE 5

Panduit IA UPS Benefits for Zone Networks

5

  • Better Integration

– Smaller width saves valuable space on the DIN rail – Single device installs more easily without interconnections – Wide operating temperature from -40 to +60° C (-40 to +140°F) – No HazMat disposal of lead acid batteries – No chance of Hydrogen outgassing, no need to vent

  • Zone Monitoring

– Power Supply A and B outputs, and load current – Proxy for enclosure inside temperature

slide-6
SLIDE 6

6

UPS Faceplate on A-B HMI

  • Panduit UPS is the only DC UPS with an

Ethernet interface

– Alternatives are expensive rack mount, AC units intended for Data Center environments – Allows remote monitoring Zone Network “health” – Power Supplies and Temperature

  • EtherNet/IP CONFORMANCE TESTED*** for

easy plug-and-play integration with Rockwell Automation FactoryTalk* network devices

– EtherNet/IP** and FactoryTalk* Network support files downloadable

Remote Management with FactoryTalk* View Faceplate

*FactoryTalk is registered by Rockwell Automation in the Patent and Trademark Office of the United States. **EtherNET/IP is a trademark of ODVA. ***EtherNet/IP CONFORMANCE TESTED is a certification mark of ODVA.