Optiguide Optiguide - Company History Optiguide Optiguide - - - PowerPoint PPT Presentation

optiguide optiguide company history optiguide optiguide
SMART_READER_LITE
LIVE PREVIEW

Optiguide Optiguide - Company History Optiguide Optiguide - - - PowerPoint PPT Presentation

Optiguide Optiguide - Company History Optiguide Optiguide - Company History Company History Company History Established in 1997 in the Technology Incubator of the TECHNION Israel Institute Incubator of the TECHNION Israel


slide-1
SLIDE 1
slide-2
SLIDE 2

Optiguide Optiguide - Company History Company History Optiguide Optiguide - Company History Company History

  • Established in 1997 in the Technology

Incubator of the TECHNION – Israel Institute Incubator of the TECHNION – Israel Institute

  • f Technology.
  • Specialized in Controlled Humidity and Cooling

solutions.

  • Main Applications: Wineries, Distilleries, Post

Harvest (Cold Storage) and Industrial applications (Clean Rooms).

slide-3
SLIDE 3
  • Wine producers are losing

wine due to evaporation during the ageing process.

The Need The Need – – Reduce Topping Reduce Topping The Need The Need – – Reduce Topping Reduce Topping

  • Annual losses: 4% - 8%
  • Topping required

frequently

:

slide-4
SLIDE 4
  • High humidity reduces evaporation and

the need for topping.

  • Annual losses reduced from 4% - 8% to less

then 1%.

  • The following Table shows the Annual

Optiguide Controlled Humidity Optiguide Controlled Humidity Solutions for Wineries and Distilleries Solutions for Wineries and Distilleries Optiguide Controlled Humidity Optiguide Controlled Humidity Solutions for Wineries and Distilleries Solutions for Wineries and Distilleries

  • The following Table shows the Annual

losses as function of the Relative Humidity in the wine cellar. Relative Humidity in % Relative Humidity in %

Temp. 95 90 85 80 75 70 65 60 55 50 45 40

F C

0.63 1.01 1.39 1.77 2.15 2.52 2.90 3.28 3.86 4.04 4.42 4.78 50 10 0.72 1.15 1.58 2.02 2.45 2.88 3.31 3.74 4.18 4.51 5.04 5.47 53.6 12 0.82 1.31 1.80 2.29 2.79 3.28 3.77 4.26 4.76 5.25 5.74 6.23 57.2 14 0.92 1.48 2.04 2.60 3.18 3.72 4.28 4.84 5.40 5.96 6.52 7.06 60.8 16 1.05 1.68 2.32 2.95 3.59 4.22 4.86 5.50 6.13 6.77 7.40 8.04 64.4 18

slide-5
SLIDE 5

Optiguide Solution: Controlled High Optiguide Solution: Controlled High Relative Humidity reduces Annual Relative Humidity reduces Annual losses by more then losses by more then 75 75% Optiguide Solution: Controlled High Optiguide Solution: Controlled High Relative Humidity reduces Annual Relative Humidity reduces Annual losses by more then losses by more then 75 75%

slide-6
SLIDE 6

Optiguide Atomizer Optiguide Atomizer Optiguide Atomizer Optiguide Atomizer

  • Low-pressure air-assisted nozzle
  • Low-pressure air-assisted nozzle
  • Micro - Droplets provide “dry fog”
  • Up to 98% RH without wetness
  • Large orifice prevents clogging
  • Maintenance free
  • Simple piping and fittings
slide-7
SLIDE 7
  • Water outlet orifice diameter: 1.5 mm
  • Water is drawn by means of a Venturi principle
  • Very small droplet size (2-10 Micron)
  • Working air pressure 6 bars

Optiguide Atomizer Optiguide Atomizer Optiguide Atomizer Optiguide Atomizer

  • Working air pressure 6 bars

Time for Particle To Fall 10 Feet (seconds) Comparative Subject in Particle Size Particle Size Range (microns) Median Volume

1.1 1.6 Moderate Rain 1000 to 500 1.6 11 Light Rain 500 to 100 11 40 Misty Rain 100 to 50 40 1020 Wet Fog 50 to 10 1020 25400 Dry Fog 10 to 2.0 Suspended in Air Fumes 1.0 to 0.01

slide-8
SLIDE 8

Optiguide Humidistat Optiguide Humidistat Optiguide Humidistat Optiguide Humidistat

  • The Optiguide patented Humidistat

(RH Sensor) measures the Relative Humidity in the wine cellar and transmit the data to the Control Unit

  • f the System.
  • f the System.
  • Accurate measurement of RH at all

ranges (Up to 99%)

.

slide-9
SLIDE 9

Optiguide Control Unit Optiguide Control Unit Optiguide Control Unit Optiguide Control Unit

  • The Control Unit responsible

to maintain the required RH level in the wine cellar

  • The control Unit reads the data

from the RH Sensor and from the RH Sensor and

  • perates the Atomizers

accordingly.

  • PC connection and data

logging software are available.

slide-10
SLIDE 10

Partial list of satisfied Partial list of satisfied clients clients Partial list of satisfied Partial list of satisfied clients clients

Spain:

* Real Tesoro – Jerez de la Frontera, (producing wine, sherry & brandy)

* Masia Bach (Codorniu Group) - Villafranca del Penedes -Bar * Pedro Domecq winery - distillery (producing brandy) - Jerez De La frontiera

  • Pedro Domecq - DYC distillery (producing whisky)- Segovia
  • Gonzales Byass – Jerez de la Frontera
  • Sandeman – Jerez de la Frontera
  • Gaspar Florido – Cadiz

France:

  • Domaine du Prieure, Anjou
  • Chile
  • Domaine du Prieure, Anjou
  • Vignobles Rollet St Emilion
  • Château Branaire
  • Château Léooville Poyferré
  • Château Beaumont
  • Château Pavie Macquin
  • Château La Mondotte
  • Château Beychevelle
  • Château Lannessan

Italy:

* Fontodi - Panzano in Chianti

* Gruppo Italiano Vini - Cantine Lamberi - Verona * Antinori - Castello della Sala -Orvieto

  • Cantina Querciabella - Greve in Chianti
  • More then 500 successful installations world wide
  • Chile
  • Vina Mont Gras, Colchagua Valley

* Vina Concha y Toro, Maipo Valley * Pisco Capel, Lqui Valley

United States:

  • Robert Mondavi - California

* Hyatt Wineyards – Washington

slide-11
SLIDE 11

Tabor Israel

Selected Client Brands Selected Client Brands Selected Client Brands Selected Client Brands

Ca Del Bosco Italy Casa Pedro Domecq Mexico Real Tesoro Spain

slide-12
SLIDE 12

Optiguide's Solution Optiguide's Solution versus Competitor versus Competitor Optiguide's Solution Optiguide's Solution versus Competitor versus Competitor

  • Wetness all over the

cellar

  • Nylon covers

Optiguide Optiguide Without Without Optiguide Optiguide

  • Nylon covers
  • Wet Floor
  • Corrosion
  • Mold
slide-13
SLIDE 13
  • Tel. +33 5 56 99 11 09 Port : +33 6 77 09 45 27