New Bedford High School Question & Answer Meeting Thursday June - - PowerPoint PPT Presentation
New Bedford High School Question & Answer Meeting Thursday June - - PowerPoint PPT Presentation
New Bedford High School Question & Answer Meeting Thursday June 10, 2010 Agenda Role of the Citys Licensed Site Professional Updates/new developments/future activities New Bedford High School Exterior Soil and
Agenda
Role of the City’s Licensed Site Professional Updates/new developments/future activities
- New Bedford High School Exterior
- Soil and groundwater impacts
- New Bedford High School Interior
- PCB building materials only
- Dr. Paul F. Walsh Athletic Field
2
Role of City’s Licensed Site Professional (LSP)
3
LSP Responsibilities
310 CMR 40.0191 Accurate and Complete Record Keeping “No
person shall make, or cause any person to make, any false, inaccurate, incomplete or misleading statement in any document which that person keeps or is required to keep pursuant to M.G.L. c. 21E, 310 CMR 40.0000”
Disclosure of Material Facts (310 CMR 40.0015) ”identify in the LSP
Opinion the material facts, data and other information known … about the disposal site that is pertinent to the LSP Opinion”
Certification of Submittals (310 CMR 40.0009) “…attest under the
pains and penalties of perjury …the material information contained in this submittal is… true, accurate and complete…”
4
New Bedford High School Exterior
5
Update/Interim Comprehensive Site Assessment
Walsh Field/NBHS Campus
TRC Interim Comprehensive Site Assessment Report
- Submitted July 21, 2009 (5,000+ pages)
- Supported remediation analysis for
Walsh Field
- No current risk
- Comprehensive site assessment
currently being updated
6
Post-Comprehensive Site Assessment Report Investigation
Work Completed at NBHS Campus
Soil sampling (December 2008 – May 2010)
- Soil borings – 407
- Surface soil samples - 82
- Over 500 PCB soil analyses
- Approximately 300 PAH soil analyses
- Over 530 metals soil analyses
- Sixteen (16) chlorinated dioxin/dibenzofuran and PCB congener
analyses
- Data collected to support remedial planning and risk assessment
7
Mechanical room seep sampling (December/January/February 2010)
- Detected chlorinated volatile organic compounds.
- Two out of four seeps
- No benzene or related compounds detected
- Evaluated sewage-related impacts
Groundwater sampling (January 2010)
- Evaluated association with groundwater
- Evaluated potential for impacts associated with sewer
system
Update/Discovery and Reporting
Volatile Organic Compound (VOC) Investigation
8
Field screened mechanical room air (Jan. 2010)
- Photoionization detector (PID) and Draeger tubes
- No impacts detected
Modeled potential indoor air impacts (Jan. 2010)
- Based on VOC concentrations in seep
- No Imminent Hazard
Reported to MassDEP (January 29, 2009)
- 72-hour notice category
- Expedited response actions taken
Update/Discovery and Reporting
Volatile Organic Compound (VOC) Investigation
9
Conducted indoor air sampling (January 31, 2010)
- Five (5) locations including mechanical room and classroom space
- Detected chlorinated volatile organic compounds
- Detected non-chlorinated volatile organic compounds (e.g., benzene)
Indoor air risk assessment (February 2010)
- Keith Middle School protocol
- No significant risk
Published Fact Sheets/Posted on City Website
- First Fact Sheet - February 4, 2010
- Updated Fact Sheet - March 2010
Update/Initial Response Actions
Volatile Organic Compound (VOC) Investigation
10
Chemical inventory/MSDS Review (January/February/ March 2010) Building drawings review (Ongoing) Field survey of first floor drains/lines/ cracks/sinks (February/March/April 2010)
- A- and B-block
- Screening and evaluating for potential sealing
- Target for periodic trap management
Update/Follow-up Investigation
Volatile Organic Compound (VOC) Investigation
11
Seepage mitigation evaluation (Initiated Feb. 2010)
- Specialty vendor visits (April 2010)
Sampled 10 storm sewer manholes and five sanitary sewer manholes (Feb. 2010) HVAC, air flow, building pressure evaluations (February 2010)
- Certified Industrial Hygienist (CIH) system review
- Mitigation by routine operation of HVAC system
Update/Follow-up Investigation
Volatile Organic Compound (VOC) Investigation
12
Update/Follow-up Investigation
Volatile Organic Compound (VOC) Investigation
Nine new monitoring wells (February 2010) Sampled all new and existing NBHS monitoring wells - 16 total (February 2010)
- Limited number of wells with detects
- No benzene or related compounds detected.
- Revised groundwater elevation contour map
Installed five additional monitoring wells before the April vacation week (April 2010)
13
Update/Follow-up Investigation
Volatile Organic Compound (VOC) Investigation
Installed/sampled 11 temporary soil gas points (February 2010)
- Low concentration detections
- Chlorinated volatile organic compounds
- Benzene and related compounds
- No vinyl chloride detected
Installed 8 permanent soil gas points (February 2010)
- Previously installed vapor barrier encountered in all
locations
14
Update/Follow-up Investigation
Volatile Organic Compound (VOC) Investigation
Camera inspection of sanitary sewer line (March 2010) Collected 12 indoor air samples (April 2010)
- Low concentration detections
- Ten of twelve samples below screening thresholds
- Chlorinated and non-chlorinated (e.g., benzene) volatile organic
compounds
- No exceedance in Classroom A-3-112/No subsurface impacts
- Mechanical Room exceedances
- Lecture Room source requires further evaluation
- No Imminent Hazard condition or current chronic risk
15
Update/April Investigation
Volatile Organic Compound (VOC) Investigation
Sampled 8 permanent soil gas points (April 2010)
- Concurrent with indoor air sampling
- Mechanical Room vapor point sampled twice
- Concentration detections
- No VOCs above screening thresholds in six of eight vapor
points
- Detections:
- Chlorinated volatile organic compounds
- Benzene and related compounds
- Vinyl chloride detected in Mechanical Room samples only
16
Update/April Investigation
Volatile Organic Compound (VOC) Investigation
Sampled 10 groundwater monitoring wells (April 2010)
- Five existing and five newly installed monitoring wells
- No VOCs in excess of state standards in eight of ten
monitoring wells
- Low concentration detections
- Chlorinated volatile organic compounds (e.g., vinyl chloride)
- Relatively small source area of VOC impacts
- Supplemental groundwater elevation gauging
17
Assessment of Mechanical Room seep mitigation options
- Specialty vendor bids in and currently under review
- Three (3) floor drains plugged (April 2010)
- Two (2) floor cracks sealed (April 2010)
Evaluation of VOC sources (other than groundwater) in Mechanical Room and Auto Shop Additional indoor air sampling of select locations Evaluation of groundwater VOC remediation options As need additional sampling of other media (e.g., soil vapor and groundwater) Updated fact sheet (June 2010)
Current Activities
Volatile Organic Compound (VOC) Investigation
18
Update/Investigation Locations
Volatile Organic Compound (VOC) Investigation
Parker Street Pool East Gym West Gym
Flagpole Island Monitoring Well Indoor Air Sample Location
Seep Sample Location Temporary Soil Gas Sample Location Permanent Soil Gas Location Sanitary Sewer Line Sample Location Drain Line Sample Location
House 4 House 3 House 2 House 1
Auditorium
19
NBHS Soil Sampling for Dioxins (April 2010)
Summary of Investigative Technical Approach
Sampling approach
- Five soil borings
- Top foot, 1-3 feet, and fill
Analytical suite
- Chlorinated dioxins and dibenzofurans and PCB
congeners
- PAHs, Metals and PCB aroclors
- VOCs (other analyses) if warranted by screening
- Analytical data under evaluation
Selection based on review of database
20
NBHS Soil Sampling for Dioxins
Approximate Sample Locations
NBHS
HG-2 HF-14 HB-26 HF-31D HF-40
N
Dioxin soil sampling locations
21
NBHS-Liberty Street Drainage Line Sampling (May 2010)
Summary of Investigative Technical Approach
Sampling approach
- Eight soil borings (three on NBHS campus)
- Top foot, 1-3 feet, and depth of drainage line
- Sampled for PCB aroclors
EPA to review data to determine regulatory jurisdiction Drainage line to be installed in accordance with MCP Utility-Related Work Plan Currently scheduled for summer 2010
- Work will not be conducted while school is in session
22
New Bedford High School PCB-Containing Building Materials
23
Update/NBHS Building Materials
Anticipated Schedule for 2010
Action
- Removal/Abatement Plan (RAP)
- Plans and specs
- Implementation
Date/Time Frame
- March 2010
- Submitted to City March 2010
- Summer 2010
24
Update/NBHS Building Materials
2010 Response Actions
B-Block Univent removal and replacement Wall paint (Rooms B-230, A-211-3, A-213-4) Foam furnishings beyond useful lifetime Maintenance/covering (caulking, sealants, mastics) Incidental asbestos management Address per the regulations in consultation with EPA
25
Update/NBHS Building Materials/Other
Future Activities
Schedule further abatement per EPA regulations Collect data for remedial planning Continue maintenance measures
26
Community Questions
NBHS Building Materials
- Q. Provide a list of classrooms where PCB Bulk
Wastes have been removed as well as classrooms that remain to be addressed?
- A. During the summer of 2009, oversaw the removal of
the following building material items:
- Laminated cabinets (B-319-3, A-205-4, and B-240)
- Painted sheet rock walls (A-206-4)
- Furniture and gym mats with polyurethane foam (various
locations)
In Summer of 2010, B-Block Univents removal and replacement and wall paint (Rooms B-230, A-211-3, A-213-4).
27
- Q. What are the most current air quality test
results of the entire school with special consideration to the areas around the rooms where TRC has been conducting removal of PCB contaminated materials?
- A. Collected 24 interior air samples for PCBs in
February 2008. The results and accompanying letter dated April 2008 are posted on the City’s website.
Community Questions
NBHS Building Materials
28
- Q. How are the materials being contained within
the classrooms before being brought out?
- A. Work performed in negative pressure enclosure
with HEPA filtration to the exterior of the building. Dust monitoring immediately outside the Containment Area. Additional monitoring for fibers where asbestos containing materials (ACM) are involved. PCB Bulk Product Wastes double wrapped in plastic prior to transfer to staging area for disposal.
Community Questions
NBHS Building Materials
29
- Q. How are the tools used for this work
decontaminated before being brought out?
- A. Contaminated building materials were double
wrapped with 6 mil poly sheeting and sealed with duct tape. High-Efficiency Particulate Air (HEPA) filter equipped vacuums used to remove dust and
- debris. Areas wiped down with a tri-sodium
phosphate (TSP) cleaning solution and rags. Containment, wrapped contaminated materials, and equipment also wiped down with TSP cleaning solution.
30
Community Questions
NBHS Building Materials
- Q. If teachers/staff are worried about a particular
issue at the NBHS, whom should they contact?
- A. If you have questions or concerns, please contact
Cheryl Henlin, City of New Bedford Environmental Stewardship Department, at (508) 991-6188 or email cheryl.henlin@newbedford- ma.gov
31
Community Questions
NBHS Building Materials
Walsh Field
32
Walsh Field - Regulatory Process Update
Work Plans for Soil Management/Remediation
- Varsity Improvements
- Soil management associated with construction and
refurbishment activities
- Varsity field water line installation on June 10, 2010
- Walsh Field Soil Removal
- Varsity diamond scheduled for Summer 2010
33
Update/Walsh Field Remediation
Soil Excavation and Landfill Re-use
Regulatory Filing
- Work Plan - October 2009
- Completed public review
period
Actions Taken
- Excavated 1,052 tons of soil
- Soil accepted at Crapo Hill
Future Response Actions
- Summer 2010 – Varsity ball
field
Completion of activities
- Varsity response action
- Varsity improvements
Partial closure report to be prepared
- Activity and Use Limitation
34
Excavation Locations at the Walsh Field Athletic Complex
Varsity Baseball Field WFB-4 WFF-5 Previous Excavation WFD-6 SB-233 WFA-10 WFA-11 WFB-11 WFD-13 WFC-13 WFG-7 Softball Field JV Baseball Field Track Shot-put Cage Upcoming Varsity Infield Excavation JV-JJ Post-9 Post-10
Excavation Outlines Bleachers/Stands Buildings Field Outlines
Walsh Field Athletic Complex
High Jump Hut Storage Building
35
Community Questions - Walsh Field
- Q. Has the remediation work been completed at Paul
Walsh Field and if not, when?
- A. Response actions at Paul Walsh Field were initiated in
the Fall of 2009. Remaining field work includes the excavation of soil from the Varsity Field and associated restoration in Summer 2010.
- Q. When remediation work is completed, will the field
be perfectly safe for all human activities?
- A. The remediation at Paul Walsh Field will render the
field suitable for active and passive recreational activities.
36