HemoDialyzer Over 1.5 Million used in Europe Over 2 Million used in China Superior Clearance Levels Product pending FDA Approval Dimesol Dialyzer Membrane-Purema Uses a unique material produced from Polyethersulfone (PES) and


slide-1
SLIDE 1

HemoDialyzer

Over 1.5 Million used in Europe Over 2 Million used in China Superior Clearance Levels Product pending FDA Approval

slide-2
SLIDE 2

Dimesol Dialyzer

Membrane-Purema

Uses a unique material produced from Polyethersulfone (PES) and Polyvinylpyrrolidone(PVP)

BPA Free

Dimesol’s unique structure increases clearance performance by 7%

Dimesol has Ondulation Membrane versus a conventional Straight membrane

  • this enhances distribution of dialysate and increases effective surface area of

dialyzer

Exclusive Technology(Poly Ethylene Terephthalate) spacer yarns that helps dialysate distribute better

Dimesol’s uniquely designed Dialyzer has a higher clearance performance than Fresenius and Gambro

Superior biocompatibility profile compared to Fresenius and Gambro

slide-3
SLIDE 3

Main Structure

Componet Housing Dialysis Membrane Cover O-ring Sealant Protective Cap

Material Polycarbonate PES Membrane Polycarbonate Silicone Resin Polyurethane Polypropylene

slide-4
SLIDE 4

GAMBRO FMC DIMESOL

slide-5
SLIDE 5

Our PES membrane is BPA Free

slide-6
SLIDE 6

Standard Straight Membrane

Dimesol’s Ondulation Membrane- proves to be superior

  • Enhance the distribution of dialysate,

Increase the effective surface area of Dialyzer to get a better clearance performance 

Distribution and Flowing of dialysate in conventional dialyzer

Effective surface area of dialyzer can be reduced under this situation

slide-7
SLIDE 7

 Further enhances the distribution of dialysate,  Increase the effective surface area of dialyzer to get a better and stable

clearance performance

slide-8
SLIDE 8

Dialyzer with PET can get higher and more stable clearance

Because of PET, our clearance performance is 7% higher than others

EXCLUSIVE …TECHNOLOGY

slide-9
SLIDE 9

Dimesol High Flux Dialyzer

Compare with FMC, Gambro, ASAHI, the clearance performance of our dialyzer with 1.4M2 is equal to their dialyzer with 1.6M2 above in the clearance of small molecular.

slide-10
SLIDE 10

Almost No change in Dimesol’s Clearance from 30 min to 240 min Very Stable clearance in dialysis treatment during 30 minutes and 240 minutes.

slide-11
SLIDE 11

More uniform pore distribution Active surface management Steeper sieving curve More selective removal range from low to super flux

slide-12
SLIDE 12

Less Protein Adsorption reduces pore clogging which gives better clearance

Very less protein adsorption, reduce pore clogging , gain better clearance

slide-13
SLIDE 13

 Dimesol H High cytochrome C Clearance compared to FMC and Gambro GAMBRO

FMC DIMESOL

slide-14
SLIDE 14

GAMBRO FMC

DIMESOL

slide-15
SLIDE 15

DIMESOL

GAMBRO FMC

slide-16
SLIDE 16

GAMBRO FMC DIMESOL

slide-17
SLIDE 17

DIMESOL GAMBRO FMC

(white blood cell) (platelet) (Complement activation) (anticoagulant factor)