Estimating Urban CO 2 Fluxes at High Spatial Resolution from In Situ - - PowerPoint PPT Presentation

estimating urban co 2 fluxes at high spatial resolution
SMART_READER_LITE
LIVE PREVIEW

Estimating Urban CO 2 Fluxes at High Spatial Resolution from In Situ - - PowerPoint PPT Presentation

Estimating Urban CO 2 Fluxes at High Spatial Resolution from In Situ Observations Alexis Shusterman, UC Berkeley shusterman.alexis@berkeley.edu http://beacon.berkeley.edu BErkeley 465m Atmospheric CO 2 Observation Network 2km ~25


slide-1
SLIDE 1

Estimating Urban CO2 Fluxes at High Spatial Resolution from In Situ Observations

Alexis Shusterman, UC Berkeley

shusterman.alexis@berkeley.edu http://beacon.berkeley.edu

slide-2
SLIDE 2

BErkeley Atmospheric CO2 Observation Network

2km

~25 independent air quality sensing “nodes” on museum and elementary school rooftops

465m

PI: Ron Cohen

slide-3
SLIDE 3

from Choi et al. 2014

  • bservations

modeled fit 1σ variation range

Particulate Matter (co-emitted with CO2)

slide-4
SLIDE 4

Vaisala GMP343 NDIR CO2 Sensor Meteorological Sensors for T, P & RH Microcomputer w/ Cell Antenna

slide-5
SLIDE 5

BEACO2N Data Set 2013

Sites: Laurel Korematsu HeadRoyce Burckhalter Kaiser ODowd ElCerrito Prescott CollegePrep StLiz NOakland

slide-6
SLIDE 6

Performance Picarro G2301 Vaisala GMP343 Accuracy ± 1 ppm ± 7 ppm Precision ± < 0.2 ppm (5s) ± 3 ppm (2s) Drift ± 6 ppm/yr ± 8 ppm/yr Weight 58 lbs 0.8 lbs Price $50,000-100,000 $3,000

slide-7
SLIDE 7

2km

Port of Oakland

slide-8
SLIDE 8

Daily CO2 Levels at Port of Oakland

ships stationary ships in motion

3 PM 8 PM 10 AM 5 AM

slide-9
SLIDE 9

strike (Oct 21) working days

3 PM 8 PM 10 AM 5 AM

Daily CO2 Levels at Port of Oakland

“Last week’s work stoppage began before dawn on October 21, as roughly 100

  • wner-
  • perators set up demonstrations

around the port […] The shutdown lifted when longshoremen returned to their posts for the 7:00 p.m. shift that evening.”

  • OaklandNorth, UC Berkeley Grad.

School of Journalism

slide-10
SLIDE 10

3 PM 8 PM 10 AM 5 AM

strike (Oct 21) working days

Daily CO2 Levels Network Wide

slide-11
SLIDE 11

10 km 10 km 10 km

PRIOR POSTERIOR DIFFERENCE

Alex Turner

10 km

slide-12
SLIDE 12

1999-2000 Emissions Factors

light-duty passenger vehicles heavy-duty diesel

Harley et al. 2005

slide-13
SLIDE 13

Vaisala GMP343 NDIR CO2 Sensor Shinyei Grove Particulate Sensor Electrochemical O3, NO, NO2 & CO Sensors

slide-14
SLIDE 14

2km

 Sensitivity  Spatial Resolution  Temporal Resolution ☐Multi-Node Analysis ☐Chemical Speciation

slide-15
SLIDE 15

Thank you!