1 | Danfoss Drives | DKDD.EP.412.A1.02
PDANFOSS – ESCO PARTNERSHI P – FOR AN ENERGY EFFI CI ENT TOMORROW
DANFOSS ESCO PARTNERSHI P FOR AN ENERGY EFFI CI ENT TOMORROW 1 | - - PowerPoint PPT Presentation
P DANFOSS ESCO PARTNERSHI P FOR AN ENERGY EFFI CI ENT TOMORROW 1 | Danfoss Drives | DKDD.EP.412.A1.02 AGENDA DANFOSS GROUP GLOBAL & I NDI A SET-UP Energy Savings in HVAC SYSTEMS DANFOSS ESCO PARTNERSHI P EXPECTATI ONS
1 | Danfoss Drives | DKDD.EP.412.A1.02
PDANFOSS – ESCO PARTNERSHI P – FOR AN ENERGY EFFI CI ENT TOMORROW
3 | Danfoss Drives | DKDD.EP.412.A1.02
DANFOSS GROUP GLOBAL
CLI MATE
While meeting the global climate challenge, our products also contribute to human productivity and well-being indoors by
ENERGY
No matter what we do, the goal is to optimize performance, increase efficiency and minimize waste. This means that our technologies enable our customers and society as a whole to get more from less.
FOOD
Our solutions meet the constant need for more and better food by improving agricultural productivity and keeping food fresh all the way to consumers with minimum waste.
I NFRASTRUCTURE
We help build the roads, buildings and energy systems for the world’s growing cities and support progress for people, communities and businesses across the world.
4 | Danfoss Drives | DKDD.EP.412.A1.02
DANFOSS POW ER SOLUTI ONS DANFOSS COOLI NG DANFOSS HEATI NG DANFOSS DRI VES
Hydrostatics # 2 W ork Function # 1 Controls Division # 2 Autom atic Controls # 1 Com m ercial Com pressors # 2 I ndustrial Autom ation # 2 Low Voltage Drives # 2 Renew able # 1 Silicon Pow er # 6 Residential Heating # 1 District Energy # 1 Hydronic Balancing # 2
DANFOSS SEGMENTS
5 | Danfoss Drives | DKDD.EP.412.A1.02
1. Security Building 2. Main Receiving Station 3. R&D Admin Building 4. Service Building 5. RC Lab 6. RC/ CC Lab & RC Production Building 7. Warehouse 8. PE Production & Lab Building 9. RC EoU Production Building
2 1 3 4 5 6 7 8 9
6 | Danfoss Drives | DKDD.EP.412.A1.02 6 |
ESCO Organization Uderstanding & EU Expectation
1 . Enery Efficiency Audit 2 . Energy Saving - Measurem ent 3 . I nstallation, Operation & Maintainance Costs Savings 4 . Energy Perform ance and Operating Guarantees - Payback
7 | Danfoss Drives | DKDD.EP.412.A1.02
Energy Efficiency & Cost Saving
6 5 % of electricity is used by electric m otors and 8 0 % of cases Motors are Oversized causing in-efficiency Maintennace Cost can be reduced by 5 0 % utilizing VFD 4 0 % energy savings w ith Variable Speed Drives controlling fans & pum ps 2 0 % of electricity is lost through traditional m echanical control
8 | Danfoss Drives | DKDD.EP.412.A1.02
HVAC, 55%
OTHERS , 25%
LIGHTI NG, 20%
TYPI CAL ENERGY CONSUMPTI ON I N A COMMERCI AL BUI LDI NG
How to Reduce HVAC Energy Consumption?
HOW TO REDUCE ENERGY CONSUMPTI ON I N HVAC?
9 | Danfoss Drives | DKDD.EP.412.A1.02
Flow ∝ Speed Pressure ∝ (Speed) 2 Energy ∝ (Speed) 3
Compressors, Fans and Pumps
How does a VFD save Energy??
20% Reduction in Speed saves 50% Energy
1 0 | Danfoss Drives | DKDD.EP.412.A1.02
I nitial Cost Benefits of VFDs
1
Om it Pow er Factor Correction equipm ent Om it additional therm al overloads Om it kW h, Am ps, Volts, Hz m etering equipm ent Low er cable & fuse ratings only – to m atch FLC. Reduction in DG Sizing as inrush current equals FLA Om it contactors/ Starting equipm ent Om it Hand / Off / Auto Selector sw itches Reduction in physical I / O points on PLC No Need for special I nverter Grade m otors – suitable for all m otors and Retrofit applications
1 1 | Danfoss Drives | DKDD.EP.412.A1.02
BUI LDI NG APPLI CATI ONS
Danfoss Drives savings 1 5 -2 0 % Energy
1 2 | Danfoss Drives | DKDD.EP.412.A1.02
IP-55 VFD with Mains Disconnect Switch Patented Back Channel Cooling Design Highest Efficiency in HVAC industry – 98% + C1 Level - EMC filter for Airport/ Hospital Requirements Dual inbuilt DC chokes for Harmonic Mitigation
SUPPORTED BY 3 6 5 X 2 4 X 7 SALES & SERVI CE NETW ORK
1 3 | Danfoss Drives | DKDD.EP.412.A1.02
I P-5 5 w ith I nbuilt Mains Disconnect Sw itch
Protected against splashing water
& Heatsink – protect from dust, water & moisture
filters are not required – less maintenance
without derating
Lockable & integrated
I P-66 for roof top mounting
1 4 | Danfoss Drives | DKDD.EP.412.A1.02
No Need for special I nverter Grade m otors – suitable for all m otors
and Retrofit applications
No Special Motors Required
Motor Friendly Save cost due to correct magnetizing. Save Energy (98% efficiency) Save Space (No need of Output chokes, 150mtr cable length) No need to select higher rating motor. No need to select inverter grade Motor.
1 5 | Danfoss Drives | DKDD.EP.412.A1.02
Case Story – PVR Cinem as
1 6 | Danfoss Drives | DKDD.EP.412.A1.02
Think I nnovation – Ahead of tim e :Reliable Perform ance – Ensure Low cost of Ow nership.
1 0 0 % Factory tested I P-5 5 w ith Disconnect sw itch – FI T-N-FORGET SOLUTI ON Harm onic and EMC Com pliance as standard Reliable Perform ance ( MTBF 2 0 0 ,0 0 0 Running hours) I nnovative cooling concepts- Saving additional panel cost and AC cost Enhanced Fire Mode inbuilt for Safety needs User Friendly Graphical ( 6 line) and W ireless Display High efficiency & Low heat Loss Longer Motor Life – No Prem ature Failure Low Total cost of ow nership – Long hardw are life
VVC+ Motor friendly algorithm Less motor heat Water Poof, Dust Proof 85% Heat taken out of Room Less AC cost/ cooling cost
Inverter dc-coils
1 7 | Danfoss Drives | DKDD.EP.412.A1.02
IMPROVE
condition
Productivity
SAVE
SOLVE
(Technology Partner)
INCREASE
Sustainability thru : Energy Efficiency , Measurem ent & Autom ation
1 8 | Danfoss Drives | DKDD.EP.412.A1.02
Danfoss Drives is the leader in driving custom ers applications
2 0 | Danfoss Drives | DKDD.EP.412.A1.02