224 W 4th Street, New York, NY B+W Architecture D.P.C. Page Sidewalk ramp INDEX 1 - EXISTING CONDITIONS IN COLOR PHOTOS. PAGE 3 2 - EXISTING AND PROPOSED DIMENSIONED DRAWINGS (INCLUDING FINISHES): PLANS PAGES 4 SECTIONS PAGES 5
B+W Architecture D.P.C.
Page Sidewalk ramp 224 W 4th Street, New York, NY
INDEX 1 - EXISTING CONDITIONS IN COLOR PHOTOS. PAGE 3 2 - EXISTING AND PROPOSED DIMENSIONED DRAWINGS (INCLUDING FINISHES): PLANS PAGES 4 SECTIONS PAGES 5 ELEVATIONS PAGES 6 3 - EXISTING CONDITIONS COLOR PHOTOS OF: SURROUNDING ADJACENT PROPERTIES. PAGE 7 INSPIRATIONS OF THE PROPOSAL (DESIGN & FINISH). PAGE 8 4 - CONFIRMATION OF THE INABILITY OF LOWER THE SILL OF THE EXISTING OPENING. PAGE 9
B+W Architecture D.P.C.
Page Sidewalk ramp 224 W 4th Street, New York, NY
EXISTING CONDITIONS PHOTOS
2 - SIDEWALK @ 4TH W STREET & 7TH AVENUE 3 - SIDEWALK @ 4TH W STREET 1 - STOREFRONT 4 - SIDEWALK AT THE ENTRY 5 - INTERIOR
B+W Architecture D.P.C.
Page Sidewalk ramp 224 W 4th Street, New York, NY
SCALE: 1/8" = 1'-0"
EXISTING - DEMOLITION PLAN
SCALE: 1/8" = 1'-0"
PROPOSED PLAN
2.0% MAXIMUM SLOPE WITHIN ALL DIRECTIONS 8.3% MAXIMUM RUNNING SLOPE 2.0% MAXIMUM CROSSING SLOPE 2.0% MAXIMUM SLOPE WITHIN ALL DIRECTIONS A A' A A'
EXISTING SIDEWALK GRADE EXISTING TOP OF THE CURB 2.3% PROPOSED SIDEWALK GRADE EXISTING TOP OF THE CURB
B+W Architecture D.P.C.
Page Sidewalk ramp 224 W 4th Street, New York, NY
SCALE: 1/2" = 1'-0"
EXISTING SECTION
SCALE: 1/2" = 1'-0"
PROPOSED SECTION
NOT ADA COMPLIANT (2.0% MAX) ATM LOBBY ATM LOBBY
B+W Architecture D.P.C.
Page Sidewalk ramp 224 W 4th Street, New York, NY
SCALE: 1/8" = 1'-0"
EXISTING ELEVATION@WEST 4th STREET
SCALE: 1/8" = 1'-0"
PROPOSED ELEVATION@WEST 4th STREET
1 1/4" TO 1 1/2" HOT-DIPPED GREY MATE STEEL FINISH RAIL MATCHING THE STOREFRONT. 1 1/4" TO 1 1/2" HOT-DIPPED GREY MATE STEEL FINISH HANDRAIL MATCHING THE STOREFRONT. 1 1/4" TO 1 1/2" HOT-DIPPED GREY MATE STEEL FINISH RAIL MATCHING THE STOREFRONT. 24H ATM ENTRANCE SUBWAY ENTRANCE
B+W Architecture D.P.C.
Page Sidewalk ramp 224 W 4th Street, New York, NY
EXISTING CONDITIONS PHOTOS OF THE SURROUNDING ADJACENT PROPERTIES
226 W 4TH STREET 226 W 4TH STREET 228 W 4TH STREET 75 CHRISTOPHER STREET 75 CHRISTOPHER STREET 75 CHRISTOPHER STREET 230 W 4TH STREET 75 CHRISTOPHER STREET
B+W Architecture D.P.C.
Page Sidewalk ramp 224 W 4th Street, New York, NY
170 W 10TH STREET 125 CHRISTOPHER STREET
ADA RAMP PROPOSAL INSPIRATION
1 1/4" STEEL HANDRAIL 1 1/2" STEEL HANDRAIL CONCRETE ADA RAMP CONCRETE ADA RAMP
A A'
B+W Architecture D.P.C.
Page Sidewalk ramp 224 W 4th Street, New York, NY
CONFIRMATION OF THE INABILITY OF LOWER THE SILL OF THE EXISTING OPENING
SCALE: 1/2" = 1'-0"
EXISTING FACADE SECTION
EXISTING STRUCTURE EXISTING STRUCTURE EXISTING STRUCTURE
SCALE: 1/16" = 1'-0"
PROPOSED PLAN EXISTING STRUCTURE
PICTURES FROM THE CONSTRUCTION IN 2007
REASONS FOR INABILITY OF LOWER THE CURRENT SILL:
- THE ADA LOBBY HAVE TO BE ADA COMPLIANT AND THERE IS NOT ENOUGH SPACE IN THAT ROOM TO BUILD AN INTERIOR ADA
COMPLIANT RAMP. (SEE PLAN BELOW).
- LOWERING THE SILL WILL REQUIRED DEMOLISHING AND REBUILDING THE EXISTING INTERIOR STRUCTURE IN THE ATM LOBBY
(SEE SECTION AND PICTURES IN THIS SHEET).
- THIS ACCESS IS THE 24-HOUR ATM LOBBY ENTRANCE AND IT IS REQUIRED TO BE ADA COMPLIANT.
NOT ENOUGH INTERIOR SPACE FOR AN ADA COMPLAINT RAMP. 24 ATM ENTRANCE 5' TURNING ADA CLEARANCE BANK OF AMERICA ENTRANCE CLOSED DURING NON-BUSINESS HOURS.