A COUSTIC A SSESSMENT & N OISE A BATEMENT A CTION P LAN FOR S T - - PowerPoint PPT Presentation

a coustic a ssessment amp
SMART_READER_LITE
LIVE PREVIEW

A COUSTIC A SSESSMENT & N OISE A BATEMENT A CTION P LAN FOR S T - - PowerPoint PPT Presentation

A COUSTIC A SSESSMENT & N OISE A BATEMENT A CTION P LAN FOR S T . M ARYS C EMENT What well talk about today: Legislation Acoustic Assessment Noise Abatement Action Plan for St. Marys Cement Important legislative documents:


slide-1
SLIDE 1

ACOUSTIC ASSESSMENT & NOISE ABATEMENT ACTION PLAN

FOR

  • ST. MARYS CEMENT
slide-2
SLIDE 2

What we’ll talk about today:

Legislation Acoustic Assessment Noise Abatement Action Plan for St. Marys Cement

slide-3
SLIDE 3

Important legislative documents:

  • Environmental Protection Act – Section 9
  • Environmental Compliance Approval
  • Noise Guideline NPC-300

Bottom line: Every facility needs an Acoustic Assessment Report (AAR) to demonstrate that it meets Provincial noise limits

slide-4
SLIDE 4

Timeline of Actions

  • 2011 – Retained HGC Engineering
  • 2011 – Noise measurements conducted
  • 2012 – Acoustic Assessment Report completed – submitted to the Ministry of the Environment
  • 2015 – Updated Acoustic Assessment Report and application
  • 2017 – Environmental Compliance Approval issued by the Ministry
  • 2017 to present – implementation of Noise Abatement Action Plan
slide-5
SLIDE 5

Acoustic Assessment Report (AAR)

Follows rules of the Ministry of the Environment

Includes detailed source inventory Noise from every source is measured Considers predictable worst-case hour Uses standardized predictive methods (ISO 9613-2)

slide-6
SLIDE 6

Noise Abatement Action Plan

Stage Timeline Action Item Stage 1 2 years Redesign of Secondary Crusher Building Dryer plant silencer Stage 2 4 years Acoustic silencer for Main Kiln Stack Acoustic silencers for six baghouse exhausts Stage 3 6 years Acoustic silencers for 17 baghouse exhausts Acoustic enclosures for two pressure blowers and kiln motor Installation of several dedicated blowers for unloading cement trucks Stage 4 8 years Acoustic silencers for 23 kiln shell cooling fans Stage 5 10 years Replacement Clinker Cooler Fans Four acoustic silencers and three enclosures – miscellaneous

slide-7
SLIDE 7

Please ask any questions