Name of Landmark Building Type of Presentation Month xx, year
657 Greenwich Street, Borough of Manhattan How to Testify Via Zoom: - - PowerPoint PPT Presentation
657 Greenwich Street, Borough of Manhattan How to Testify Via Zoom: - - PowerPoint PPT Presentation
April 28 th , 2020 Name of Landmark Building Type of Presentation Month xx, year Public Hearing The current proposal is: Item 3, LPC-20-07474 657 Greenwich Street, Borough of Manhattan How to Testify Via Zoom:
St Luke’s School Outdoor Space Plan 2020-02-27 1
ST LUKE’S OUTDOOR SPACE PLAN Perimeter Wall Design Existing Conditions Christopher Street
St Luke’s School Outdoor Space Plan 2020-02-27 2
THREE STORY & BASEMENT BRICK THREE STORY & BASEMENT B R I C K No.491 No.489
5 1 52
N
- .
1 3 5 FOUR STORY BRICK N
- .
1 3 7 4
- 5
S T O R Y B R I C K & BSMT BRICK
2 9 30
& BSM'T T W O S T O R Y B R I C K
GUTTER EX NEW GRATE GUTTER EX E M (3)EX NORTHPerimeter Wall Existing Conditions
1
CHRISTOPHER ST H U D S O N S T
5 3 1 2 3 Project Area Christopher St - Spring 2019 2 1 5 3 Christopher St- Fall 2019 w/ Temporary Fence 2
St Luke’s School Outdoor Space Plan 2020-02-27 3
Existing Temporary Fence Extension Existing Chain Link Fence on Christopher Street
Upper School Basketball Hoop (10’ Rim)
EXISTING FENCE W/ TEMPORARY SCREEN 32’ EXISTING GATE 3’ EXISTING 9’ TALL FENCE W/ TEMPORARY SCREEN 40’ EXISTING TEMPORARY 12’ TALL FENCE EXTENSION W/ TEMPORARY SCREEN 40’ EXISTING 9’ TALL FENCE W/ TEMPORARY SCREEN 20’
Existing Fence Existing Fence Extension 1 2 1 2
HUDSON STREET
2" GALVANIZED STEEL FABRIC (9 1.66" O.D. TOP RAIL, TYP. 1.66" O.D. BOTTOM RAIL. 4" O.D. POST SLEEVE OVER TOP OF EXISTING CONCRETE 1.66" O.D. HORIZONTAL BRACES REQUIRED 1/2" O.D. DIAGONAL TRUSS ROD WITH TURNBUCKLE REQUIRED AT CHANGE OF 12'-0" PUBLIC SIDEWALK CONCRETE CURB TOP OF EXISTING POST TO REMAIN.. CUT POST AS REQUIRED FOR SLEEVE. CUT NO MORE THAN 50% OF POST HEIGHT. 9' PIER BEYOND 4" O.D. POST EXTENSION GROUT
May 01 2019 - 9:20am M:\18-981 St. Luke s School Outdoor Space Plan\dwg\09-sheets\L-402 SITE DETAILS - FENCE.dwg2" GALVANIZED STEEL FABRIC (9 GAUGE) 1.66" O.D. TOP RAIL, TYP. 1.66" O.D. BOTTOM RAIL. 4" O.D. POST SLEEVE OVER EXISTING POST TOP OF EXISTING CONCRETE CURB 9'-0" EXISTING FENCE 1.66" O.D. HORIZONTAL BRACES REQUIRED AT CHANGE OF FENCE HEIGHT 4'-6" 4'-6" 1/2" O.D. DIAGONAL TRUSS ROD WITH TURNBUCKLE REQUIRED AT CHANGE OF FENCE HEIGHT 3'-0" FENCE EXTENSION EXISTING FENCE PROPOSED FENCE PUBLIC SIDEWALK CONCRETE CURB TOP OF EXISTING POST TO REMAIN.. CUT POST AS REQUIRED FOR SLEEVE. CUT NO MORE THAN 50% OF POST 4" O.D. POST EXTENSION
May 01 2019 - 9:20am M:\18-981 St. Luke s School Outdoor Space Plan\dwg\09-sheets\L-402 SITE DETAILS - FENCE.dwgEXISTING FENCE EXTENSION
St Luke’s School Outdoor Space Plan 2020-02-27 4
Existing Temporary Fence Extension Custom Screen Printed Mesh on Christopher St. Fence
Manufacturer: Fence Screen Product Line: 311 Series Printed Fence Wrap Material: MAXFlex PVC vinyl coated mesh with custom
- graphics. Available in 80% and 100% view blockage.
Shown here in 80% view blockage. Existing fence screen
Name of Landmark Building Type of Presentation Month xx, year