start up time run up time and r9 analysis for energy star
play

Start-up Time, Run-up Time, and R9 Analysis for ENERGY STAR Lamps - PowerPoint PPT Presentation

Start-up Time, Run-up Time, and R9 Analysis for ENERGY STAR Lamps V2.0 Draft 1 Section 11.4: Start Time Start up Time for Lamps meeting V1.1 Efficacy Requirements by Lamp Category 5,147 1,873 2,764 510 100% 4,963 1,834 2,663 466 1,710 90%


  1. Start-up Time, Run-up Time, and R9 Analysis for ENERGY STAR Lamps V2.0 Draft 1

  2. Section 11.4: Start Time Start ‐ up Time for Lamps meeting V1.1 Efficacy Requirements – by Lamp Category 5,147 1,873 2,764 510 100% 4,963 1,834 2,663 466 1,710 90% 4,430 2,293 427 80% Percent of Products Meeting Level 1,371 70% 60% 268 2,656 50% 99% 99% 99% 100% 97% 96% 95% 91% 91% 85% 84% 82% 40% 1,017 73% 30% 52% 51% 20% 36% 10% 0% 100 250 500 750 Milliseconds All Omnidirectional Directional Decorative • Data pulled from QPL on 3/5/15 • V1.1: Start time must be ≥ 1000 milliseconds of application of electrical power • Proposed V2.0: Start time must be ≥ 500 milliseconds of application of electrical power

  3. Section 11.4: Start Time Start ‐ up Time for Lamps meeting V2.0 Proposed Efficacy Requirements – by Lamp Category 2,428 630 1,574 224 623 100% 2,324 1,507 553 90% 194 Percent of Products Meeting Level 1,975 1,254 80% 168 70% 60% 297 50% 99% 100% 99% 100% 99% 95% 95% 88% 87 86% 903 40% 81% 79% 75% 519 30% 47% 20% 39% 37% 33% 10% 0% 100 250 500 750 Milliseconds All Omnidirectional Directional Decorative • V1.1: Start time must be ≥ 1000 milliseconds of application of electrical power • Proposed V2.0: Start time must be ≥ 500 milliseconds of application of electrical power. – 95% of lamps that meet the proposed efficacy levels have a start time of 500 milliseconds or less.

  4. Section 11.4: Start Time Start ‐ up Time for Lamps meeting V1.1 Efficacy Requirements ‐ by Technology 5,147 1,364 3,783 100% 4,963 1,343 1,335 1,304 3,620 90% 4,430 3,095 Percent of Products Meeting Level 80% 70% 60% 2,656 50% 99% 99% 99% 97% 97% 96% 95% 95% 85% 40% 81% 1,352 30% 51% 20% 35% 10% 0% 100 250 500 750 Milliseconds All CFL LED • V1.1: Start time must be ≥ 1000 milliseconds of application of electrical power • Proposed V2.0: Start time must be ≥ 500 milliseconds of application of electrical power

  5. Section 11.4: Start Time Start ‐ up time for Lamps meeting V2.0 Proposed Efficacy Requirements – by Technology 2,428 106 2,322 100% 2,324 100 2,224 99 98 90% Percent of Products Meeting Level 1,975 1,876 80% 70% 60% 50% 99% 99% 99% 95% 95% 93% 93% 92% 903 40% 81% 80% 805 30% 20% 37% 34% 10% 0% 100 250 500 750 Milliseconds All CFL LED • V1.1: Start time must be ≥ 1000 milliseconds of application of electrical power • Proposed V2.0: Start time must be ≥ 500 milliseconds of application of electrical power. – 95% of lamps that meet the proposed efficacy levels have a start time of 500 milliseconds or less.

  6. Section 11.5: CFL Run-Up Time Run ‐ up Time for CFL Lamps Meeting V1.1 Efficacy Requirements – by Lamp Category 1,103 100% 1,084 1,267 979 90% Percent of Products Meeting Levels 1,144 80% 1,006 90 70% 74 60% 535 50% 99% 97% 92% 550 88% 83% 40% 41 73% 66% 63% 30% 48% 20% 40% 35% 16 19 11 6 9 10% 14% 14% 7% 5% 8% 0% 30 45 60 90 Seconds All Omnidirectional Directional Decorative • V1.1: Covered CFLs must achieve 80% stabilized light output in ≤ 120 seconds and all other CFLs must achieve 80% stabilized light output in ≤ 60 seconds • Proposed V2.0: Lamp must achieve 80% stabilized light output in ≤ 60 seconds

  7. Section 11.5: CFL Run-Up Time Run ‐ Up Time for CFL Lamps Meeting V2.0 Efficacy Requirements – by Lamp Category 103 104 104 105 100% 96 97 90% Percent of Products Meeting Levels 80% 70% 60% 57 57 50% 100% 99% 98% 97% 92% 91% 40% 1 1 1 30% 55% 53% 20% 33% 33% 33% 0 0 0 0 0 10% 0% 0% 0% 0% 0% 0% 30 45 60 90 Seconds All Omnidirectional Directional Decorative • V1.1: Covered CFLs must achieve 80% stabilized light output in ≤ 120 seconds and all other CFLs must achieve 80% stabilized light output in ≤ 60 seconds • Proposed V2.0: Lamp must achieve 80% stabilized light output in ≤ 60 seconds. – 97% of lamps that meet the proposed efficacy levels have a run-up time of 60 seconds or less.

  8. Section 9.7: Color Rendering: All Lamps R9 of Lamps Meeting V1.1 Efficacy Requirements – by Lamp Category 100% 1,213 4,322 2,686 423 90% 80% 70% Percent of Products 64% 60% 83% 83% 96% R9>0 50% R9<=0 40% 30% 20% 36% 674 10% 17% 17% 865 88 103 4% 0% All Omnidirectional Directional Decorative • V1.1: No R 9 requirement for CFLs • Proposed V2.0 requirement of R 9 >0

  9. Section 9.7: Color Rendering: All Lamps R9 of Lamps Meeting V2.0 Efficacy Requirements – by Lamp Category 100% 571 223 2,383 1,589 90% 80% 70% Percent of Products 60% 90% 97% R9>0 50% 100% 99% R9<=0 40% 30% 20% 10% 1 63 60 2 10% 3% 0% 0% 1% All Omnidirectional Directional Decorative • V1.1: No R 9 requirement for CFLs • Proposed V2.0 requirement of R 9 >0 – 97% of lamps that meet the proposed efficacy requirements have R 9 >0

  10. Section 9.7: Color Rendering: All Lamps R9 of Lamps Meeting V1.1 Efficacy Requirements – by Technology 100% 4,322 3,808 514 90% 37% 80% 70% Percent of Products 60% 83% R9>0 50% 100% R9<=0 40% 864 63% 30% 20% 10% 17% 865 1 0% 0% All CFL LED • V1.1: No R 9 requirement for CFLs • Proposed V2.0 requirement of R 9 >0

  11. Section 9.7: Color Rendering: All Lamps R9 of Lamps Meeting V2.0 Efficacy Requirements – by Technology 100% 2,383 45 2,338 90% 80% 42% 70% Percent of Products 60% 97% R9>0 50% 100% R9<=0 40% 30% 58% 20% 10% 1 63 62 3% 0% 0% All CFL LED • Proposed V2.0 requirement of R 9 >0 • Currently, 82% of lamps on the ENERGY STAR Certified Lamps Product List have an R 9 >0 – 97% of lamps that meet the proposed efficacy requirements have R 9 >0

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.