Our goal Our goal ABB Avangard is transforming from being a - - PowerPoint PPT Presentation

our goal our goal
SMART_READER_LITE
LIVE PREVIEW

Our goal Our goal ABB Avangard is transforming from being a - - PowerPoint PPT Presentation

Our goal Our goal ABB Avangard is transforming from being a traditional supplier to be a market partner with the intention to offer broad customised services not exclusively focusing on product sales ABB ABB Avangard Retrofit Retrofit


slide-1
SLIDE 1

ABB Avangard

ABB

Our goal Our goal

ABB Avangard is transforming from being a traditional supplier to be a market partner with the intention to offer broad customised services not exclusively focusing on product sales

slide-2
SLIDE 2

ABB Avangard

ABB

Exchange Replacement Modernization Rehabilitation

Upgrading existing, outdated systems with the most modern components to

  • ptimize

technical, reliability and profitability aspects of the system.

Increase in capacity Upgrading Refurbishing

Retrofit Retrofit

slide-3
SLIDE 3

ABB Avangard

ABB

Retrofit Retrofit

ABB Avangard performs following retrofit activities: retrofit of medium voltage switchgears Retrofit of secondary systems Retrofit of high voltage disconnectors by exchanging the existing operating mechanism with motor drive mechanism type SM 1500 Overhaul of oil - minimum circuit breaker type MMO

slide-4
SLIDE 4

ABB Avangard

ABB

Retrofit of medium voltage Retrofit of medium voltage switchgear switchgear

Movable parts: commutation apparatus

Fast physical and Fast physical and moral ageing moral ageing

slide-5
SLIDE 5

ABB Avangard

ABB

Retrofit of medium voltage Retrofit of medium voltage switchgear switchgear

Secondary commutation: relay protection control equipment measuring equipment

Fast moral ageing Fast moral ageing

slide-6
SLIDE 6

ABB Avangard

ABB

Retrofit of medium Retrofit of medium voltage switchgear voltage switchgear

Our range of services: replacing of the old breaker replacing disconnector switches replacing instrument transformers renewal of phase insulation renewal of bus bars and feeder bars fitting of protection devices

slide-7
SLIDE 7

ABB Avangard

ABB

Retrofit of medium Retrofit of medium voltage switchgear voltage switchgear

You gain: increased reliability and safety reduced maintenance costs increased remaining life time with minimum 20 years

slide-8
SLIDE 8

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

Thermo Plant Blagoevgrad, BG

Retrofit of Russian switchgear by replacing the old oil - minimum breaker with SF6 circuit breaker type HPA

slide-9
SLIDE 9

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

Retrofit of Russian switchgear by replacing the oil- minimum breaker with SF6 circuit breaker type HPA

slide-10
SLIDE 10

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

Retrofit of polish switchgear by replacing the oil - minimum breaker with vacuum breaker type VD4

slide-11
SLIDE 11

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

Retrofit of Russian switchgear by replacing of the airblast breaker with vacuum breaker type VM1 Retrofit of Russian switchgear by replacing the oil- minimum breaker with SF6 circuit breaker type HPA

slide-12
SLIDE 12

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

Retrofit of Russian switchgear by replacing the old

  • il-minimum circuit

breaker with vacuum breaker type VM1

slide-13
SLIDE 13

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

slide-14
SLIDE 14

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

NPP Kozloduy , BG

Retrofit of Russian switchgear by replacing the oil- minimum breaker with SF6 circuit breaker type HD4

slide-15
SLIDE 15

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

HPP Pirin, BG

Retrofit of Bulgarian switchgear by replacing the

  • il- minimum breaker with SF6

circuit breaker type HPA

slide-16
SLIDE 16

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

Kremikovtzi, BG

Retrofit of Russian switchgear by replacing the oil- minimum breaker with SF6 circuit breaker type HD4

slide-17
SLIDE 17

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

Bor’s Glass Plant , Russia

Retrofit of Russian switchgear by replacing the

  • il- minimum breaker with

SF6 circuit breaker type HD4 and HD4

slide-18
SLIDE 18

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

TPP Bobov Dol , BG

Retrofit of Polish switchgear by replacing the oil- minimum breaker with SF6 circuit breaker type VD4

slide-19
SLIDE 19

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

TPP Maritza II , BG

Retrofit of Russian switchgear by replacing the air breaker with vacuuv circuit breaker type VM1

slide-20
SLIDE 20

ABB Avangard

ABB

ABB Avangard ABB Avangard -

  • retrofit solutions

retrofit solutions

TPP Varna; BG

Retrofit of Russian switchgear by replacing the the oil- minimum breaker with vacuumcircuit breaker type VM1

slide-21
SLIDE 21

ABB Avangard

ABB

Reference List Reference List

1 Retrofit with SF6 circuit breaker type HPA 12 kV with cassette Maritsa East Mines, BG 7 1 Retrofit with SF6 circuit breaker type HPA 12 kV NPP Kozloduy, BG 6 86 Retrofit with SF6 circuit breakers type HPA 12 kV and HD4 12 kV Bor’s Glass Plant, Russia 5 112 Retrofit with vacuum circuit breaker type VM1 12 kV TPP Bobov dol, BG 4 2 Retrofit with SF6 circuit breaker type HPA 12 kV HPP Pirin, BG 3 1 Retrofit with SF6 circuit breaker type HPA 12 kV Power supply, Blagoevgrad, BG 2 4 Retrofit with SF6 circuit breaker type HPA 12 kV Heat supply, Sofia, BG 1

Q-ty Product description Customer No.

slide-22
SLIDE 22

ABB Avangard

ABB

Reference List Reference List

1 Retrofit with vacuum circuit breaker type VD4 12 kV Airport Vrajdebna, BG 14 1 Retrofit with vacuum circuit breaker type VD4 24 kV “Remotex”, Radnevo, BG 13 4 Retrofit with vacuum circuit breaker type VD4 24 kV ABB CalorEmag, Germany 12 126 Retrofit with vacuum circuit breaker type VM1 12 kV TPP Varna 11 1 Retrofit with vacuum circuit breaker type VD4 24 kV ATSA, BG 10 1 Retrofit with SF6 circuit breaker type HPA 12 kV Kremikovtzi, BG 9 2 Retrofit with vacuum circuit breaker type VM1 12 kV TPP Maritsa East II, BG 8

Q-ty Product description Customer No.

slide-23
SLIDE 23

ABB Avangard

ABB

Reference List Reference List

196 26 Retrofit of 6kV switchgear with

  • SF6 circuit breaker type HD4
  • Voltage transformers

NPP Kozloduy, BG 18 1 Retrofit with vacuum circuit breaker type VM1 Start Engineering,Varna, BG 17 2 Retrofit with SF6 circuit breaker type HPA24 ET “G.Tasev”, Pernik, BG 16 15 18 Retrofit with vacuum circuit breakers type VM1 12 kV Relay protections type SPA_ TPP “Deven”, BG 15

Q-ty Product description Customer No.