our goal our goal
play

Our goal Our goal ABB Avangard is transforming from being a - PowerPoint PPT Presentation

Our goal Our goal ABB Avangard is transforming from being a traditional supplier to be a market partner with the intention to offer broad customised services not exclusively focusing on product sales ABB ABB Avangard Retrofit Retrofit


  1. Our goal Our goal ABB Avangard is transforming from being a traditional supplier to be a market partner with the intention to offer broad customised services not exclusively focusing on product sales ABB ABB Avangard

  2. Retrofit Retrofit Upgrading existing, outdated systems with the most modern components to optimize technical, reliability and profitability aspects of the system. � Exchange � Increase in capacity � Replacement � Upgrading � Modernization � Refurbishing � Rehabilitation ABB ABB Avangard

  3. Retrofit Retrofit ABB Avangard performs following retrofit activities: � retrofit of medium voltage switchgears � Retrofit of secondary systems � Retrofit of high voltage disconnectors by exchanging the existing operating mechanism with motor drive mechanism type SM 1500 � Overhaul of oil - minimum circuit breaker type MMO ABB ABB Avangard

  4. Retrofit of medium voltage Retrofit of medium voltage switchgear switchgear Movable parts: � commutation apparatus Fast physical and Fast physical and moral ageing moral ageing ABB ABB Avangard

  5. Retrofit of medium voltage Retrofit of medium voltage switchgear switchgear Secondary commutation: � relay protection � control equipment � measuring equipment Fast moral ageing Fast moral ageing ABB ABB Avangard

  6. Retrofit of medium Retrofit of medium voltage switchgear voltage switchgear Our range of services: � replacing of the old breaker � replacing disconnector switches � replacing instrument transformers � renewal of phase insulation � renewal of bus bars and feeder bars � fitting of protection devices ABB ABB Avangard

  7. Retrofit of medium Retrofit of medium voltage switchgear voltage switchgear You gain: � increased reliability and safety � reduced maintenance costs � increased remaining life time with minimum 20 years ABB ABB Avangard

  8. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard Thermo Plant Blagoevgrad, BG Retrofit of Russian switchgear by replacing the old oil - minimum breaker with SF 6 circuit breaker type HPA ABB ABB Avangard

  9. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard Retrofit of Russian switchgear by replacing the oil- minimum breaker with SF 6 circuit breaker type HPA ABB ABB Avangard

  10. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard Retrofit of polish switchgear by replacing the oil - minimum breaker with vacuum breaker type VD4 ABB ABB Avangard

  11. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard Retrofit of Russian switchgear by Retrofit of Russian replacing of the switchgear by replacing airblast breaker the oil- minimum with vacuum breaker with SF 6 circuit breaker type VM1 breaker type HPA ABB ABB Avangard

  12. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard Retrofit of Russian switchgear by replacing the old oil-minimum circuit breaker with vacuum breaker type VM1 ABB ABB Avangard

  13. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard ABB ABB Avangard

  14. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard NPP Kozloduy , BG Retrofit of Russian switchgear by replacing the oil- minimum breaker with SF 6 circuit breaker type HD4 ABB ABB Avangard

  15. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard HPP Pirin, BG Retrofit of Bulgarian switchgear by replacing the oil- minimum breaker with SF 6 circuit breaker type HPA ABB ABB Avangard

  16. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard Kremikovtzi, BG Retrofit of Russian switchgear by replacing the oil- minimum breaker with SF 6 circuit breaker type HD4 ABB ABB Avangard

  17. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard Bor’s Glass Plant , Russia Retrofit of Russian switchgear by replacing the oil- minimum breaker with SF 6 circuit breaker type HD4 and HD4 ABB ABB Avangard

  18. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard TPP Bobov Dol , BG Retrofit of Polish switchgear by replacing the oil- minimum breaker with SF 6 circuit breaker type VD4 ABB ABB Avangard

  19. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard TPP Maritza II , BG Retrofit of Russian switchgear by replacing the air breaker with vacuuv circuit breaker type VM1 ABB ABB Avangard

  20. ABB Avangard - - retrofit solutions retrofit solutions ABB Avangard TPP Varna; BG Retrofit of Russian switchgear by replacing the the oil- minimum breaker with vacuumcircuit breaker type VM1 ABB ABB Avangard

  21. Reference List Reference List No. Customer Product description Q-ty Retrofit with SF6 circuit breaker type 1 Heat supply, Sofia, BG 4 HPA 12 kV Retrofit with SF6 circuit breaker type 2 Power supply, Blagoevgrad, BG 1 HPA 12 kV Retrofit with SF6 circuit breaker type 3 HPP Pirin, BG 2 HPA 12 kV 4 TPP Bobov dol, BG Retrofit with vacuum circuit breaker 112 type VM1 12 kV 5 Bor’s Glass Plant, Russia Retrofit with SF6 circuit breakers type 86 HPA 12 kV and HD4 12 kV 6 NPP Kozloduy, BG Retrofit with SF6 circuit breaker type 1 HPA 12 kV 7 Maritsa East Mines, BG Retrofit with SF6 circuit breaker type 1 HPA 12 kV with cassette ABB ABB Avangard

  22. Reference List Reference List No. Customer Product description Q-ty TPP Maritsa East II, BG Retrofit with vacuum circuit breaker 8 2 type VM1 12 kV Kremikovtzi, BG Retrofit with SF6 circuit breaker type 9 1 HPA 12 kV ATSA, BG Retrofit with vacuum circuit breaker 10 1 type VD4 24 kV 11 TPP Varna Retrofit with vacuum circuit breaker 126 type VM1 12 kV 12 ABB CalorEmag, Germany Retrofit with vacuum circuit breaker 4 type VD4 24 kV 13 “Remotex”, Radnevo, BG Retrofit with vacuum circuit breaker 1 type VD4 24 kV 14 Airport Vrajdebna, BG Retrofit with vacuum circuit breaker 1 type VD4 12 kV ABB ABB Avangard

  23. Reference List Reference List No. Customer Product description Q-ty TPP “Deven”, BG Retrofit with vacuum circuit breakers 15 15 type VM1 12 kV Relay protections type SPA_ 18 16 ET “G.Tasev”, Pernik, BG Retrofit with SF6 circuit breaker type 2 HPA24 17 Start Engineering,Varna, BG Retrofit with vacuum circuit breaker 1 type VM1 NPP Kozloduy, BG Retrofit of 6kV switchgear with 18 - SF6 circuit breaker type HD4 196 - Voltage transformers 26 ABB ABB Avangard

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.