isover multicomfort house students contest edition 2018
play

ISOVER MULTICOMFORT HOUSE STUDENTS CONTEST EDITION 2018 DRAFTERS: - PowerPoint PPT Presentation

ISOVER MULTICOMFORT HOUSE STUDENTS CONTEST EDITION 2018 DRAFTERS: VEIS ALINA MECHSHANOVA NURIYA CONSULTANT: YASKEVICH VLADIMIR KAZAKHSTAN/ SATBAYEV UNIVERSITY INSPIRATION CONCEPT GENERAL VIEW MASTER PLAN FLOOR PLAN AT THE LEVEL -5600 -


  1. ISOVER MULTICOMFORT HOUSE STUDENTS CONTEST EDITION 2018 DRAFTERS: VEIS ALINA MECHSHANOVA NURIYA CONSULTANT: YASKEVICH VLADIMIR KAZAKHSTAN/ SATBAYEV UNIVERSITY

  2. INSPIRATION

  3. CONCEPT

  4. GENERAL VIEW

  5. MASTER PLAN

  6. FLOOR PLAN AT THE LEVEL -5600 - Locker room - Parking - Pedestrian way - Recreation pavilion - Shop - Place for car - Boat rental - Mechanic area

  7. GENERAL VIEW

  8. GENERAL VIEW

  9. FLOOR PLAN AT THE LEVEL +4500 Short-term type of residence Long-term type of residence Permanent type of residence

  10. FLOOR PLAN AT THE LEVEL +4500 One-room apartment Two-room apartment Three-room apartment

  11. GENERAL VIEW

  12. GENERAL VIEW

  13. SCHEME OF ENERGY EFFICIENT SOLUTIONS

  14. AIRATIONAPARTAMENTS’ SCHEMES FOR DIFFERENT WEATHER

  15. SECTION A-A

  16. SECTION B-B

  17. AKUSTIC AND INSOLATION SCHEME

  18. AKUSTIC AND INSOLATION SCHEME

  19. MULTI-COMFORT DESIGNER A. PROJECT DATA I. OVERHEATING CALCULATION G. HVAC OBJECT MCH 1 EXTERIOR THERMAL TRANSMITTANCE 1161.30 HEAT RECOVERY SYSTEM: 95.00 CLIMATE ZONE DUBAI GROUND THERMAL TRANCMITTANCE: 26986.31 SUBSOIL HEAT EXCHANGER: 33.00 CONSTRUCTION: NEW VENTILATION TRANSMITTION AMBI… 937.86 BUILDING VENTILATION TRANSMITTION GRO… 0.00 H. SUMMER VENTILATION STRATEGY BUILDING TYPE: RESIDENTIAL SOLAR APERTURE: 141.68 USAGE FOR LIVING SUMMER AIR EXCHANGE RATE (… 0.20 FREQUENCY OF OVERHEATING: 47.82 DESIGN T( ºC) 22 B. AREA INPUT SUMMER AIR EXCHANGE RATE (… 0 WITH HEAT RECOVERY SYSTEM NO SUM OF LIVING AREA: 5280.00 NIGHT VENTILATION: FULLY OPEN WIND +‘(25%) 1h’ SUM OF HEATED SPACE VOLUME: 14210.00 DAY VENTILATION: TITED WINDOWS +‘(25%) 1h' A/V RATIO: 0.37 SUM OF THERMAL ENVELOPE: 3415.80 I. HEAT DEMAND CALCULATIONS C. OPAQUE ELEMENTS TRANSMISSION HEAT LOSSES: 1423.81 ROOF FLAT: 0.11 VENTILATION HEAT LOSSES: 418.94 WALL AGAINST AIR: 0.11 TOTAL HEAT LOSSES: 1842.74 SLAB AGAINST GROUND: 0.10 INTERNAL HEAT GAINS: 1333.56 D. WINDOWS/ DOORS AVAILABLE SOLAR HEAT GAINS: 2553.59 WINDOWS: 0.73 TOTAL HEAT GAINS: 1819.20 DOORS: 0.80 ANNUAL HEAT DEMAND: 23.55 SPECIFIC ANNUAL HEAT DEMAND: 0.00 E. QUALITY AIRTIGHTNESS RATE: 0.60 I. COOLING DEMAND CALCULATIONS THERMAL BRIDGE-FREE: YES Specific Annual Heat NEGATIVE HEAT LOADS: 28705.78 F. SHADING VENTILATION HEAT LOSSES: 26986.31 Demand : 0.00 kWh/a per m2 (STANDART + SUMMER SHADING) TOTAL HEAT LOSSES: 55692.09 315º 0.07 INTERNAL HEAT GAINS: 266.11 Specific Annual Cooling 225º 0.70 AVAILABLE SOLAR HEAT GAINS: 2553.59 135º 0.00 USEFULL HEAT LOSSES: 142.76 Demand : 10 . 52 kWh/a per m2 45º 0.70 USEFULL COOLING DEMAND: 55549.33 HORIZONTALº 0.70 SPECIFIC ANNUAL COOLING DEMAND: 10.52

  20. THANK YOU FOR YOUR ATTENTION

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.