Innovation in procedures for used oil sampling p p g Matteo Campatelli Mecoil Diagnosi Meccaniche s.r.l., Firenze, Italy Matteo Paoli Mecoil Diagnosi Meccaniche s.r.l., Firenze, Italy g , , y and Giuseppe Adriani How to improve sampling


  1. Innovation in procedures for used oil sampling p p g Matteo Campatelli Mecoil Diagnosi Meccaniche s.r.l., Firenze, Italy Matteo Paoli Mecoil Diagnosi Meccaniche s.r.l., Firenze, Italy g , , y and Giuseppe Adriani

  2. How to improve sampling procedures p p g p by Jim Fitch (Practicing Oil Analysis – Best Practices – July 1998) by Jim Fitch (Practicing Oil Analysis – Best Practices – July 1998) ANSWER: ANSWER: The Ultra Clean Vacuum Device or “U C V D ” patented by Mecoil is The Ultra Clean Vacuum Device, or U.C.V.D. , patented by Mecoil is the ideal device for easy and simple oil sampling procedures. The UCVD is hassles ‐ free and avoids contamination, messes, or spilling. UCVD is hassles free and avoids contamination, messes, or spilling. Thanks to this innovative vacuum patented technology, the procedure for obtaining a realistic sample is ready at your fingertips! Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  3. Current procedures for: “Clean Oil Sampling” Clean Oil Sampling Currently, it is recommended to use recommended to use a zip ‐ lock sandwich bag and tools like a bag and tools like a hand pump, in order to reduce the risk of to reduce the risk of cross ‐ contamination. Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  4. Technical Requirements (Internationally approved standard vessel size) Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  5. The Bright Idea g O i i Originated from the use t d f th of vacuum suction as a medical method for medical method for blood sampling Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  6. How does it work The oil is Sterile vacuum ‐ drawn inside proof tube the tube Progressive Filling The sample tube is 90% full tube filling completed completed Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  7. U.C.V.D. – Ultra Clean Vacuum Device Safety y S Special control i l t l cap valve Vacuum at 950 950 mbar b Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  8. U.C.V.D. – Ultra Clean Vacuum Device Oil is drawn Oil is drawn into the bottle Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  9. U.C.V.D. – Ultra Clean Vacuum Device • PETG PETG • 100 ml capacity • 85°C 85°C maximum operation i ti temperature • • International Patent Pending International Patent Pending • Applicable to any viscosity range Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  10. U.C.V.D. – Customization Two different bottle sizes and several cap colours to satisfy every customer’s request customer s request. Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  11. Testing on U.C.V.D. g Several vessels are under extended testing with vacuum with vacuum applied and monitored weekly Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  12. Sampling procedure; Suction test p g p ; Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  13. Sampling procedure; Suction test p g p ; Test with 10% vacuum (-0.9 bar) U.C.V.D. is U.C.V.D. is (90%) almost full Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  14. Suction Test: Results Viscosity grade: ISO VG 100 Room Temp : 19°C Room Temp.: 19 C Testing how the vacuum level can influence the r.h.: 36% amount (cm³) and flow rate (cm³/s) of the oil drawn. Tubing length: 50 cm Pressure Pressure Volume Volume Time Time Flow Flow n° [cm 3 ] [cm 3 /s] [bar] [s] 1 ‐ 0,919 , 123,6 , 85 1,45 , 2 ‐ 0,808 109,9 87 1,26 3 ‐ 0,712 98,1 100 0,98 4 ‐ 0,608 78,5 105 0,75 5 ‐ 0,511 66,7 115 0,58 6 ‐ 0,411 55,0 108 0,51 7 ‐ 0,314 43,2 100 0,43 Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  15. Suction Test: Summary 140,0 140 0 Time [s] Flow [cm3/s] / 1,60 120,0 150 1,40 100,0 1,20 130 me [cm3] 80,0 1,00 [s] 110 Volum 0 80 0,80 Time 60,0 0,60 90 40,0 0,40 70 20,0 0,20 0,0 50 0,00 ‐ 1 1 ‐ 0,8 0,8 ‐ 0,6 0,6 ‐ 0,4 0,4 ‐ 0,2 0,2 0 0 ‐ 1 1 ‐ 0 8 0,8 ‐ 0 6 0,6 ‐ 0 4 0,4 ‐ 0 2 0,2 0 0 Pressure [bar] Pressure [bar] A linear trend is observed for the amount of fluid and time (flow rate) depending on the applied vacuum. Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  16. Time vs. Viscosity Measuring time requested to draw 100 ml Measuring time requested to draw 100 ml of oil at a given temperature for different ISO VG. Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  17. Time vs. Viscosity Room Temp.: 21°C R h : 46% R.h.: 46% Tubing length: 50 cm Quantity: 100 ml V@15°C V@40°C V@100°C Bottle Bottle Bottle Vacuum Bottle Vacuum Oil Oil n° Oil Temperature V@ Oil Temp. Time Weight Vacuum Weight cSt cSt cSt g g ‐ g °C cSt s 1 Light Fuel 18,22 7,88 # 29,749 29,551 0,198 22 14,0 5 2 Gasoline 2,1 1,39 # 29,826 29,623 0,203 22 1,8 4 3 ISO VG 10 # 9,72 , 2,56 , 29,835 29,643 , , 0,192 , 22 18,5 , 5 4 ISO VG 22 # 20,51 4,13 29,866 29,660 0,206 22 44,9 9 5 ISO VG 32 # 30,71 5,48 29,836 29,621 0,215 22 71,2 12 6 6 ISO VG 46 ISO VG 46 # # 42 59 42,59 6 96 6,96 29,722 29,517 29 722 29 517 0 205 0,205 22 22 102,7 102 7 18 18 7 ISO VG 68 # 67,97 8,6 29,848 29,626 0,222 22 189,8 39 8 ISO VG 100 # 88,46 10,35 29,672 29,461 0,211 22 255,6 43 9 ISO VG 150 # 131,37 13,33 29,724 29,519 0,205 22 406,7 75 10 ISO VG 220 # 191,91 17,42 29,751 29,536 0,215 22 622,5 97 11 ISO VG 320 11 ISO VG 320 # # 333 55 333,55 23 71 23,71 29 883 29 629 29,883 29,629 0 254 0,254 22 22 1227 4 1227,4 173 173 Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  18. Time vs. Viscosity y = 0,149x ISO VG Time @40°C Time vs. Viscosity @ 22°C R² = 0,982 cSt s 180 170 10 <2 160 22 3 150 150 32 5 140 46 7 130 68 10 120 100 15 110 100 150 22 Time [s] 90 220 33 T 80 80 320 48 70 460 69 60 50 40 Draw time is due only to 30 viscosity 20 10 10 0 Time = 0.15 x Viscosity 0 200 400 600 800 1000 1200 Viscosity [cSt] Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  19. Accelerated leakage test g U d Under stress, pressure >1,5 t >1 5 bar, to check the leakage point Ext. Press. Ext Press Initial Press Initial Press. Time Time Finish Press. Finish Press n° bar bar day bar 1 1 1 5 1,5 ‐ 0 94 0,94 2 2 ‐ 0 93 0,93 2 1,5 ‐ 0,94 10 ‐ 0.93 Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  20. Weight & Pressure Correlation g Bottle average weight: 29.599 g y = 6,463x Negative Pressure vs. Weight R² = 0,987 1 0,95 ure [bar] Bottle & 0,9 Vacuum Pressure Delta Weight 0,85 0 85 Negative Pressu [g] [ ‐ bar] [g] 0,8 0,75 29,454 0,924 0,145 0,7 29 463 29,463 0,898 0 898 0,136 0 136 N 0,65 29,466 0,87 0,133 0,6 0,1 0,11 0,12 0,13 0,14 0,15 29,468 0,845 0,131 Delta Weight [g] Delta Weight [g] 29,47 0,819 0,129 Peso [g] Press. [bar] 0,001 0,006 29,477 0,794 0,122 0,002 0,013 29,479 0,772 0,12 0,003 0,003 0,019 0,019 29,482 0,748 0,117 0,004 0,026 Negative Pressure Level = 0,005 0,032 29,488 0,725 0,111 0,006 0,039 6.463* ∆ Weight 29 49 29,49 0,704 0 704 0 109 0,109 0,007 0,007 0,045 0,045 0,008 0,052 29,494 0,675 0,105 0,009 0,058 29,497 0,663 0,102 0,01 0,065 Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  21. How use the Ultra Clean Vacuum Device Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

  22. Why this the Right Choice y g • QUICK • QUICK drawn any practical viscosity in seconds drawn any practical viscosity in seconds. • EASY • EASY hands free sampling no other device is hands ‐ free sampling, no other device is required. • CLEAN pre ‐ charged vacuum allows a high cleanliness level cleanliness level. • SURE SURE no possible cross ‐ contamination. no possible cross contamination. • SAFE no oil spills, leaks, keeps oil away from p , , p y the user and the environment. Mecoil Diagnosi Meccaniche s.r.l. – OilDoc Conference 2011

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.