Compliance Inspection Programs How to get it funded! Eoin OGrady - - PowerPoint PPT Presentation

compliance inspection programs
SMART_READER_LITE
LIVE PREVIEW

Compliance Inspection Programs How to get it funded! Eoin OGrady - - PowerPoint PPT Presentation

Developing and Sustaining Compliance Inspection Programs How to get it funded! Eoin OGrady PhD CRSP Manager, Laboratory Safety and University Biosafety Officer Sep 18, 2019 Canadian Biosafety Symposium, Toronto Preparation for the new


slide-1
SLIDE 1

Developing and Sustaining Compliance Inspection Programs

How to get it funded!

Eoin O’Grady PhD CRSP Manager, Laboratory Safety and University Biosafety Officer

Sep 18, 2019 Canadian Biosafety Symposium, Toronto

slide-2
SLIDE 2

2012 Phase I, II Consultations 2013 Phase III Consultations 2014 Draft Regs & Stds 2014 0.25 FTE hired

2

Preparation for the new licencing regime…

slide-3
SLIDE 3

3

2015 saw lots of internal program changes…

slide-4
SLIDE 4

4

2015 saw lots of internal program changes…

slide-5
SLIDE 5

5

2015 saw lots of internal program changes…

slide-6
SLIDE 6

6

2015 saw lots of internal program changes…

slide-7
SLIDE 7

7

2015 saw lots of internal program changes…

slide-8
SLIDE 8

Dec 2015 Submitted Mar 2016 Needs Improvement Sep 2016 Non- compliance Oct 2016 Re- submitted

8

The licence application “needs improvement”...

“The University BSO has made a business case for additional personnel resources to be allocated to the Biosafety Program. That business case is under consideration at present. In the interim, a part-time Biosafety Program Advisor is hired to assist with compliance inspections.”

slide-9
SLIDE 9

9

UCalgary ranks 12th among U15 in terms of biosafety FTE

1 2 3 4 Calgary Dalhousie, Queens,… Western, Saskatchewan Simon Fraser Manitoba McGill UBC McMaster Toronto Alberta Total FTE U15 counterparts U15 X U15 Y U15 Z U15 …

slide-10
SLIDE 10

Inspections to cover diverse lab activities

Specific biohazards ? Biosafety labs (400) + Radioactive labs (50) Chemical labs (550)

slide-11
SLIDE 11

Purpose of biosafety compliance inspection program

  • Monitor compliance for specific biohazards
  • Improve compliance assurance
  • Improve and ensure consistency
  • Report on non-compliances
slide-12
SLIDE 12

Scope developed against criteria

slide-13
SLIDE 13

Let’s prioritize our biohazard risks

Specific Biohazard Types

1. HIV 2. Prion (CL2) 3. Aquatic pathogens (AQC2) 4. Sand fly (Arthropod) 5. Small Animal Containment (CL2-SA) 6. Small Animal-Prion Containment (CL2-SA-Prion) 7. Large Animal Containment (CL2-Ag)

slide-14
SLIDE 14

Adhere to annual inspection process

Notify Inspect Report Follow- up Close

14

slide-15
SLIDE 15

1 2 3 4 5 6 7 8 9 10 HMRB HRIC HSC BI KNB VSRS QB

# Laboratories Building

SA HIV Arthropod Prion SA-Prion Aquatic Ag

Variety and complexity of lab types across campuses

Foothills (15) Main (3) Spyhill (3)

slide-16
SLIDE 16

Floor plans help in understanding the facility

  • ffice

anteroom autoclave freezers work area

slide-17
SLIDE 17

Visuals help others unfamiliar with facility

slide-18
SLIDE 18

Visuals (Laboratory-specific)

slide-19
SLIDE 19

Central, staffed autoclave facilities are leaders…

slide-20
SLIDE 20

Laboratory-specific PPE keeps us safe (and it’s fun!)

slide-21
SLIDE 21

Common findings prompt further action

  • Fabric chairs
  • Open lab doors
  • Exposed wood
  • Housekeeping
  • Non-reproducible key to access labs
  • Training records
  • SOPs
  • Decontamination records
slide-22
SLIDE 22

Common Findings (Facilities-specific)

  • Eyewash, ceiling lights, floor/wall notches, sealant, fire extinguishers
slide-23
SLIDE 23

Sand fly facilities creates new challenges

  • Sand fly is “alien” – CFIA
  • Sand fly is a vector for Leishmania
  • Leishmania is a parasite – PHAC

23

slide-24
SLIDE 24

Sand fly facilities creates new challenges

  • Sand fly is “alien” – CFIA
  • Sand fly is a vector for Leishmania
  • Leishmania is a parasite – PHAC
  • What kind of SOP is needed for “Escaped sand flies”?!

24

slide-25
SLIDE 25

Sand fly facility has some performance problems

30 deficiencies in 2017 including:

  • Material to buy/install
  • SOPs
  • Medical surveillance
  • Training records

24% 0% 10% 6% 76% 100% 90% 94%

OCT-17 MAY-17 OCT-18 CURRENT

  • N. PETERS LAB

(SAND FLY, HRIC 4B37A)

Non-Compliances Compliances Oct 16

slide-26
SLIDE 26

Sand fly facility has some performance problems

30 deficiencies in 2017 including:

  • Material to buy/install
  • SOPs
  • Medical surveillance
  • Training records

13 deficiencies in 2018 including:

  • SOPs
  • Housekeeping
  • Training records

24% 0% 10% 6% 76% 100% 90% 94%

OCT-17 MAY-17 OCT-18 CURRENT

  • N. PETERS LAB

(SAND FLY, HRIC 4B37A)

Non-Compliances Compliances Oct 16

slide-27
SLIDE 27

Find deficiencies before the regulators – HIV (RG3)

7 deficiencies including:

  • Housekeeping
  • Minor SOP updates
  • Eyewash maintenance
slide-28
SLIDE 28

Find deficiencies before the regulators – HIV (RG3)

7 deficiencies including:

  • Housekeeping
  • Minor SOP updates
  • Eyewash maintenance
slide-29
SLIDE 29

Double the deficiencies vs other HIV (RG3) lab

15 deficiencies including:

  • Doors stoppers
  • Doors kept open
  • Training records
  • Decontamination records
slide-30
SLIDE 30

Prion facility has significant wear and tear

32 deficiencies including:

  • Sealant broken
  • Access control
  • Training records
  • HACF/Lab manual/SOPs update
  • Decontamination process
slide-31
SLIDE 31

Year-over-year improvements are realized

5 deficiencies including:

  • Housekeeping
  • Labelling for transport
  • Training
  • Gasket repair
slide-32
SLIDE 32

Year-over-year improvements are realized

Oct 2016 - the business case for a part-time, permanent position is endorsed by:

  • Director, EHS
  • AVP, Risk
  • AVP, Research
  • University Veterinarian
  • Chair, Biosafety Committee
slide-33
SLIDE 33

Year-over-year improvements are realized

Oct 2016 - the business case for a part-time, permanent position is endorsed by:

  • Director, EHS
  • AVP, Risk
  • AVP, Research
  • University Veterinarian
  • Chair, Biosafety Committee

Dec 2018, position is funded

slide-34
SLIDE 34

Purpose of biosafety compliance inspection program

  • Monitor compliance for specific biohazards
  • Improve compliance assurance
  • Improve and ensure consistency
  • Report on non-compliances
slide-35
SLIDE 35

Purpose of biosafety compliance inspection program

  • Monitor compliance for specific biohazards
  • Improve compliance assurance
  • Improve and ensure consistency
  • Report on non-compliances