Aperture studies for dAu on Feb. 24 We started put in DX angle for the yellow beam, then apply the D0 offset and angle to reduce the angle. The DX BPMs showed we did reduce the angle, however, we saw loss any time we implement changes. We


  1. Aperture studies for dAu on Feb. 24

  2. ● We started put in DX angle for the yellow beam, then apply the D0 offset and angle to reduce the angle. The DX BPMs showed we did reduce the angle, however, we saw loss any time we implement changes. We scan the angle, only be able to achieve 0.5 mrad instead of 1.1 mrad (on Feb 10). Therefore this was due to beam with a suspected large transverse emittance. We also tested +/- 3mm separation bumps. Beam lifetime at injection was fine with that separation with 12 yellow bunches and full blue ring. This is intent to gain aperture with reduced separation.

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.