Webinar on..... Earthquake Resistant Construction of Buildings Date - - PowerPoint PPT Presentation

webinar on
SMART_READER_LITE
LIVE PREVIEW

Webinar on..... Earthquake Resistant Construction of Buildings Date - - PowerPoint PPT Presentation

Webinar on..... Earthquake Resistant Construction of Buildings Date :- 28/07/2020 Time :- 4:00 to 5:20 Session :- 3 Regulation & Enforcement Bldg. Codes & Safety Codes pertaining to seismic zone. Building Bye-Laws.


slide-1
SLIDE 1

Webinar on.....

Earthquake Resistant Construction of Buildings

 Date :- 28/07/2020  Time :- 4:00 to 5:20  Session :- 3  Regulation & Enforcement

  • Bldg. Codes & Safety Codes pertaining to seismic

zone.

  • Building Bye-Laws.
  • Licensing & Certification of Engineers & Architects.
  • Technical Audit & Monitoring.

T

  • pic Conducted By......
  • Er. C.B.Bhatt, Surveyor, Bhuj ADA, Bhuj-Kutchh

1

slide-2
SLIDE 2

Bldg Codes & Safety Codes Pertaining to Seismic Zone

Indian Standards on Earthquake Engineering :-

  • National Standard Body of India, is a Statutory Organization under the

Bureau of Indian Standards Act 1986.

  • Formulation of Indian Standards on different subjects of Engineering through

various Division Councils.

  • The Civil Engineering Division Council :- standardization in the field of Civil

Engineering including

A) Structural Engineering, B) Building materials and components, C) Planning Design D) Construction and Maintenance of Civil Engineering Structures E) Construction Practices F) Safety in Building etc.

  • These standards are evolved based on consensus principle through a

network of technical committee comprising representatives from Govt. & Non Govt Organizations.

2

slide-3
SLIDE 3

 IS 1893:1984 Criteria for Earthquake

Resistant Design of Structures

 Deals with earthquake resistant design of

structures and is applicable to buildings; elevated structures; bridges; dams etc.

 Also gives a map which divides the country

into five seismic zones based on the seismic intensity.

Bldg Codes & Safety Codes Pertaining to Seismic Zone

3

slide-4
SLIDE 4

 IS 1893(Part 1):2002 Criteria for Earthquake Resistant

Design of Structures : Part 1 General provisions and Buildings’ :-

 Contains provisions that are general in nature and applicable to all

structures.

 Also contains provisions that are specific to buildings only.  Covers general principles and design criteria, combinations, design

spectrum, main attributes of buildings, dynamic analysis, apart from seismic zoning map and seismic coefficients of important towns, map showing epicenters, map showing tectonic features and lithological map

  • f India.

Bldg Codes & Safety Codes Pertaining to Seismic Zone

4

slide-5
SLIDE 5

 IS 1893(Part 4):2005 `Criteria for

Earthquake Resistant Design of Structures: Part 4 Industrial Structures Including Stack Like Structures

 This standard deals with earthquake

resistant design of the industrial structures (plant and auxiliary structures) including stack-like structures such as process industries, power plants, textile industries,

  • ff-shore structures and

marine/port/harbour structures. Bldg Codes & Safety Codes Pertaining to Seismic Zone

5

slide-6
SLIDE 6

 IS 4326:1993 Earthquake Resistant Design and

Construction of Buildings - Code of Practice

 Provides guidance in selection of materials, special features of

design and construction for earthquake resistant buildings including masonry construction, timber construction, prefabricated construction etc.

 In this standard, it is intended to cover the specified features of

design and construction for earthquake resistance of buildings of conventional types.

 The general principles to be observed in the construction of such

earthquake resistant buildings as specified in this standard are Lightness, Continuity

  • f

Construction, avoiding/reinforcing Projecting and suspended parts, Building configuration, strength in various directions, stable foundations, Ductility

  • f

structure, Connection to non-structural parts and fire safety of structures.

Bldg Codes & Safety Codes Pertaining to Seismic Zone

6

slide-7
SLIDE 7

 IS 13827:1993 Improving Earthquak

e Resistance of Earthen Buildings – Guidelines

 The guidelines covered in this standard

deal with the design and construction aspects for improving earthquake resistance of earthen houses, without the use of stabilizers such as lime, cement, asphalt, etc.

Bldg Codes & Safety Codes Pertaining to Seismic Zone

7

slide-8
SLIDE 8

 IS 13828:1993 Improving Earthquak

e Resistance of Low Strength Masonry Buildings – Guidelines

 Covers the special features of design and

construction for improving earthquake resistance of buildings of low-strength masonry.

Bldg Codes & Safety Codes Pertaining to Seismic Zone

8

slide-9
SLIDE 9

 IS 13920:1993 Ductile Detailing of Reinforced

Concrete Structures Subjected to Seismic Forces – Code of Practice

 Covers the requirements for designing and detailing of

monolithic reinforced concrete buildings so as to give them adequate toughness and ductility to resist severe earthquake shocks without collapse.

 Material specifications are indicated for lateral force resisting

elements of frames.

 The provisions are also given for detailing of reinforcement

in the wall web, boundary elements, coupling beams, around

  • penings, at construction joints, and for the development,

splicing and anchorage of reinforcement.

Bldg Codes & Safety Codes Pertaining to Seismic Zone

9

slide-10
SLIDE 10

 IS 13935:2009 Seismic Evaluation,

Repair and Strengthening of Masonry Buildings – Guidelines

 Covers

the selection

  • f

materials and techniques to be used for repair and seismic strengthening of damaged buildings during earthquakes.

 Also covers the damageability assessment

and retrofitting for upgrading of seismic resistance

  • f

existing masonry buildings covered under IS 4326 and IS 13828. Bldg Codes & Safety Codes Pertaining to Seismic Zone

10

slide-11
SLIDE 11

 SP 7 : 2016  National Building Code of India 2016 (NBC 2016)

 First published -1970 at the instance of Planning Commission  First revised -1983.  Three major amendments were issued to the 1983 version, two in 1987 and

the third in 1997. S

 Second revision - 2005, to which two amendments were issued in 2015.  The National Building Code of India (NBC), a comprehensive building Code, is

a national instrument providing guidelines for regulating the building construction activities across the country.

 Serves as a Model Code for adoption by all agencies involved in building

construction works be they Govt or Non Govt agencies.

 Mainly contains administrative regulations, development control rules and

general building requirements; fire safety requirements; stipulations regarding materials, structural design and construction (including safety); building and plumbing services; approach to sustainability; and asset and facility management.

Bldg Codes & Safety Codes Pertaining to Seismic Zone

11

slide-12
SLIDE 12

Building Bye Laws :

  • Earlier there are different Dev. Control Regulations in different

Urban areas of state

  • In year 2017 Govt. introduced CGDCR-2017 to avail ease &

uniformity in interpretation & appropriated enforcement

  • f

Development Control Regulations.

  • Government has prepared a comprehensive document for smooth

implementation & interpretation of Regulations under Gujarat Town Planning & Urban Development Act - 1976

  • It is called as Comprehensive General Development Control

Regulations – 2017, which is finalized wide Govt. Notification Dt.03/10/2019

  • All urban Development Authorities, Area Development Authorities

& Municipal Corporations classified in D1 to D10 categories

  • Which is divided in three parts
  • Part I :- Procedure Regulations
  • Part II :- Planning Regulations
  • Part III :-Performance Regulations

12

slide-13
SLIDE 13
  • CGDCR – 2017
  • Part I :- Procedure Regulations (Legal Part)
  • Definitions
  • Dev. Permission & B.U. Permission
  • Responsibilities of Owner &/or Developer & POR
  • Procedure during construction
  • Schedules & Forms

Building Bye Laws :

13

slide-14
SLIDE 14
  • CGDCR – 2017
  • Part II :- Planning Regulations (Enforcement Part)
  • General Planning & Dev. Regulations
  • FSI, Margin, Parking, Dev. of Land etc.,
  • Gamtal & Core Walled city
  • Other than Gamtal & Core Walled city
  • Mining, quarrying & Brick Inn
  • Advertising Display & Communication Infrastructure

Building Bye Laws :

14

slide-15
SLIDE 15

New Construction on 9mts Road in Gamtal New Construction on 12mts Road in Gamtal

TOWN PLANNING SCHEMES

slide-16
SLIDE 16

BHUJ DEVELOPMENT PLAN

slide-17
SLIDE 17 OFFICE TREASURY MOHAMMAD PANAH MASJID ALFRED HIGH SCHOOL PROPOSED 24 M WIDE DEVELOPMENT PLAN ROAD

Before re-planning the area

TOWN PLANNING SCHEMES

slide-18
SLIDE 18 OFFICE TREASURY MOHAMMAD PANAH MASJID 12 M T S. W I D E R O A D 12 M T S. W I D E R O A D 1 2 M T S . W I D E R O A D 12 M T S. W I D E R O A D 7 . 5 M T S . W I D E R O A D W I D E R O A D 7.5 M T S. W I D E R O A D 7.5 M T S. 7 . 5 M T S . W I D E R O A D 7 . 5 M T S . W I D E R O A D 6 M T S. W I D E R O A D 6 M T S. W I D E R O A D 6 M T S . W I D E R O A D 6 M T S . W I D E R O A D 4.5 M T S. W I D E R O A D 4.5 M T S. W I D E R O A D 4.5 M T S. W I D E R O A D 4.5 M T S. W I D E R O A D 3 M T S. W I D E R O A D 4.5 M T S. W I D E 6 M T S. W I D E R O A D 4.5 M T S. W I D E R O A D 4 . 5 M T S . W I D E R O A D 4.5 M T S. W I D E R O A D 4.5 M T S. W I D E 3 M T S . W I D E R O A D 4.5 M T S. W I D E 4 . 5 M T S . W I D E 4.5 M T S. W I D E 3 M T S. W I D E R O A D 6 M T S. W I D E R O A D 3M T S. W I D E 3 M T S. W I D E R O A D 4.5 M T S. W I D E R O A D 3 M T S. W I D E 3 M T S . W I D E R O A D 3 M T S . W I D E 3 M T S. W I D E 3 M T S. W I D E R O A D 3 M T S. W I D E 2.5 M T S. W I D E R O A D 9 M T S . W I D E R O A D 12 M T S. W I D E R O A D 9 M T S. W I D E R O A D 3 M T S. W I D E 4.5 M T S. W I D E R O A D 3 M T S. W I D E 3 M T S . W I D E 3 M T S. W I D E 4 . 5 M T S . W I D E 6 M T S . W I D E R O A D 4.5 M T S. W I D E R O A D 4.5 M T S. W I D E 3 M T S. W I D E 4 . 5 M T S . W I D E R O A D 3 M T S. W I D E ALFRED HIGH SCHOOL 4.5 M T S. W I D E R O A D 6 M T S. W I D E R O A D P R O P O S E D D E V E L O P M E N T P L A N R O A D
  • 2
4 M W I D E

    

After re-planning the area

TOWN PLANNING SCHEMES

slide-19
SLIDE 19

Ravalwadi Relocation Site

slide-20
SLIDE 20

Mundra Relocation Site

slide-21
SLIDE 21
  • CGDCR – 2017
  • Part III :- Performance Regulations (Enforcement Part)
  • Building & Infrastructure
  • Architectural Elements, Parkign, Lighting, Ventilation,

Drainage etc.,

  • Fire Prevention & Safety
  • Special Buildings performance Regulations
  • Structural Safety
  • Environmental Management
  • Pollution Control
  • Maintenance & Up gradation
  • Conformity to other ACTs & Regulations
  • Quality Control & Inspection

Building Bye Laws :

21

slide-22
SLIDE 22

Licensing & Certification of Engineers & Architects

  • Responsibilities of Owner And/ Or Developer and Persons of

Record (POR) is summarized in Chaper 4 of CGDCR-2017, Part I (Procedure Regulations)

  • POR- Engineer of Record, Developer on Record, Clerk of Works
  • n Record,Architect on Record, Stru. Engineer on Record.....
  • Contains minimum qualifications & Competence Requirement for

POR

  • Duties & Responsibilities.....
  • POR

can be registered through Online portal https://enagar.gujarat.gov.in/

  • POR, who is registered with Any one authority in District can work

as a consultant in all authorities & Municipalities of District.

  • POR, who is registered with any Municipal Corporation or UDA

can work as a consultant in all Municipal corporations & Urban development Authorities of State.

22

slide-23
SLIDE 23

T echnical Audit & Monitoring

  • As per provisions of CGDCR – 2017.........
  • EOR Or/ And AOR – Responsible to make planning according to

CGDCR-2017 & other Regulations.

  • SEOR – Responsible to make design of structure in accordance with I.S.

codes.

  • SOR & COWOR – Responsible to ensure the construction should be as

per plan approved by Authority & Structural Design provided by SEOR

  • POR has to ensure to make plan according to Regulations and to

implement construction on site as per approved plan approved by Authority & Design by Structural Designer.

  • Authority makes cross check at every stage of the construction i.e. Plinth,

Lintel, Slab level.

  • After completion of the construction authority inspect the building on

submission of completion by POR which should be as per approved plan after satisfactory arrangements of rain water harvesting, drainage, tree plantation etc., authority issue Building Use Permission for the Approved Building.

23

slide-24
SLIDE 24

 Query?  Questions??  Suggestions.......  Thank

You......

  • Er. C.B.Bhatt

 E-Mail :- cbbhatt_bhatt@yahoo.com  (M) :- 9427289141

24