the vermont residential energy code 2015 workshop content
play

THE VERMONT RESIDENTIAL ENERGY CODE 2015 WORKSHOP CONTENT T - PowerPoint PPT Presentation

THE VERMONT RESIDENTIAL ENERGY CODE 2015 WORKSHOP CONTENT T he E ne rg y Co de Ba c kg ro und / Ove rvie w Whic h b uilding s, whe n? Ob lig a tio ns o f the b uilde r Wha t s Re q uire d? Ba sic Re q uire me


  1. THE VERMONT RESIDENTIAL ENERGY CODE 2015

  2. WORKSHOP CONTENT • T he E ne rg y Co de • Ba c kg ro und / Ove rvie w • Whic h b uilding s, whe n? • Ob lig a tio ns o f the b uilde r • Wha t’ s Re q uire d? • Ba sic Re q uire me nts • Pe rfo rma nc e Re q uire me nts • F iling the Pa pe rwo rk 4/7/2015 2

  3. TODAY’S PRESENTATION Spo nso re d b y L a Va lle y Building Supply De live re d b y E ffic ie nc y Ve rmo nt 4/7/2015 3

  4. MAJOR CHANGES FOR 2015 • Co mplia nc e with Stre tc h c o de re q uire d fo r Ac t 250 pro je c ts • Ne w insula tio n re q uire me nts a nd pa c ka g e s • ASHRAE 62.2 o ptio n fo r ve ntila tio n • Ma ke up a ir re q uire me nts fo r e xha ust ho o ds • Air tig htne ss re duc e d fro m 5 to 3 ACH50 • 75% o f lig hts must b e hig h e ffic a c y 4/7/2015 4

  5. THE LEGISLATION -- ACT 20 OF 1997 “RESIDENTIAL BUILDING ENERGY STANDARDS” • Ba se d o n I nte rna tio na l E ne rg y Co nse rva tio n Co de • Pe rfo rma nc e -b a se d sta nda rd • So me Ve rmo nt-spe c ific a dditio ns/ e xe mptio ns • Se lf-c e rtific a tio n b y b uilde r • T hre e -ye a r re visio n c yc le • Pub lic re vie w pro c e ss • 2015 c o de a pplie s to a ll pro je c ts tha t sta rt c o nstruc tio n o n o r a fte r Ma rc h 1, 2015 4/7/2015 5

  6. WHICH BUILDINGS MUST COMPLY? • Ne w c o nstruc tio n, lo w-rise re side ntia l • One a nd two fa mily dwe lling s • Multifa mily ho using thre e sto rie s o r le ss • Do e s no t inc lude c o mme rc ia l b uilding s • But do e s inc lude re side ntia l pa rt o f mixe d-use • E xisting lo w-rise re side ntia l b uilding s • Additio ns • Only the a dditio n ne e ds to c o nfo rm • Re no va tio ns, windo w & e q uipme nt re pla c e me nt 4/7/2015 6

  7. ALTERATIONS & RENOVATIONS • Applie s to a dditio ns, a lte ra tio ns, re no va tio ns o r re pa irs to a n e xisting b uilding , b uilding syste m o r po rtio n the re o f (una lte re d po rtio ns ne e d no t c o mply) • Applie s to c ha ng e o f unc o nditio ne d to c o nditio ne d spa c e • Applie s to insula tio n pro je c ts • Re pla c e me nt windo ws must c o mply • Sto rm windo ws a nd g la ss re pla c e me nt e xe mpt 4/7/2015 7

  8. ALTERATIONS & RENOVATIONS • Wa lls e xe mpt if c a vitie s a re no t e xpo se d o r if the y a re a lre a dy full o f insula tio n • Re ro o fing e xe mpt unle ss she a thing o r insula tio n is e xpo se d a nd c a vity is e mpty • Re pla c e me nt o f le ss tha n 50% o f lig ht fixture s a nd re pla c e me nt o f b ulb & b a lla st in e xisting fixture s is e xe mpt 4/7/2015 8

  9. LOG HOMES • Ve rmo nt c o de disting uishe s b e twe e n lo g ho me s a nd e ve rything e lse • I n g e ne ra l, lo g ho me s a re a llo we d to b e le ss e ffic ie nt • But the re a re mo re string e nt re q uire me nts fo r o the r pa rts o f the b uilding to pa rtia lly ma ke up fo r the diffe re nc e 4/7/2015 9

  10. EXEMPTIONS • E xtre me lo w e ne rg y use • le ss tha n 1 wa tt pe r sq ua re fo o t pe a k lo a d • Mo b ile ho me s • T itle VI , Na tio na l Ma nufa c ture d Ho using Co nstruc tio n & Sa fe ty Sta nda rds Ac t o f 1974 • Site -c o nstruc te d c o mpo ne nts still must c o mply • Building s (o r a re a s) no t he a te d o r c o o le d • Hunting Ca mps • Histo ric b uilding s c a n a pply fo r e xe mptio n 4/7/2015 10

  11. OWNER/BUILDER PROJECTS • Spe c ific a lly e xe mpte d fro m me e ting the te c hnic a l re q uire me nts o f the c o de • Owne r must dire c t the de ta ils o f c o nstruc tio n, inc luding e ne rg y ite ms, must live in the b uilding • Must do c a lc ula tio ns, c o mple te a nd file the Owne r/ Builde r Disc lo sure Sta te me nt • Must disc lo se in writing to po te ntia l b uye rs b e fo re purc ha se a nd sa le a g re e me nt 4/7/2015 11

  12. LIABILITY • Ho me o wne r ma y ta ke c ivil a c tio n a g a inst pe rso n c e rtifying b uilding • Da ma g e s ma y inc lude inc re a se d e ne rg y c o sts a nd c o sts to b ring the b uilding into c o mplia nc e (a s we ll a s c o urt, a tto rne ys’ fe e s) • Cla ims must b e file d within six ye a rs 4/7/2015 12

  13. THERMAL REQUIREMENTS • T he ne xt fe w slide s o utline the the rma l re q uire me nts o f the ne w c o de • F o r a ve ra g e ho use s, insta lling the se le ve ls will me e t the c o de • But the c o de re q uire s o ve ra ll pe rfo rma nc e , a nd the re a re ma ny wa ys to g e t the re • So yo u c a n insta ll a sse mb lie s le ss e ffic ie nt tha n this, b ut yo u ha ve to ma ke up fo r it so me whe re e lse in the b uilding , a nd yo u ha ve to use a me tho d tha t a c c o mmo da te s tha t tra de -o ff 4/7/2015 17

  14. Thermal Requirements WINDOWS • F e ne stra tio n (e xc e pt skylig hts) • Ma ximum 0.32 U-va lue (0.30 fo r lo g ho me s) • Skylig hts • Ma ximum 0.55 U-va lue • Gla zing a re a • Ma ximum 20% • Up to 15 sq ft o f g la zing a nd o ne do o r is e xe mpt 4/7/2015 18

  15. Thermal Requirements INSULATION • Ce iling s • Minimum R-49 • F o r fla t c e iling s, R-38 de e me d to me e t R-49 if full he ig ht unc o mpre sse d o ve r to p wa ll pla te • Slo pe d c e iling s OK @ R-30 if no t mo re tha n 500 sq ft o r 20% o f c e iling a re a , whic he ve r is le ss • I nsta lle r must c e rtify de ta ils, sig n, po st in c o nspic uo us lo c a tio n. De pth ma rke rs re q uire d fo r b lo wn a ttic s 4/7/2015 19

  16. Thermal Requirements INSULATION • Wo o d fra me wa lls • Minimum R-25 • R-13 c a vity insula tio n plus R-10 insula te d she a thing de e me d to c o mply. • Ma ss wa lls • Minimum R-15 • R-20 re q uire d if mo re tha n ha lf o f the insula tio n is o n the inte rio r • (L o g ho me s e xe mpt fro m wa ll R-va lue re q uire me nt) 4/7/2015 20

  17. Thermal Requirements INSULATION • F lo o rs • Minimum R-30 (R-38 fo r lo g ho me s) • Minimum R-20 OK if it fills the who le c a vity • Must ma inta in pe rma ne nt c o nta c t with unde rside o f sub flo o r 4/7/2015 21

  18. Thermal Requirements INSULATION • Ba se me nt wa lls • Minimum R-15 c o ntinuo us o r R-20 c a vity • F ro m to p o f wa ll to 10 ft b e lo w g ra de o r to b a se me nt flo o r, whic he ve r is le ss • E xte rio r insula tio n must ha ve pro te c tive c o ve ring 4/7/2015 22

  19. Thermal Requirements INSULATION • Unve nte d c ra wl spa c e : • Minimum R-15 c o ntinuo us o r R-20 inte rio r c a vity • Pe rma ne ntly fa ste ne d to wa ll do wn to flo o r a nd the n ve rtic a lly a nd/ o r ho rizo nta lly fo r a t le a st a n a dditio na l 24 inc he s • Must ha ve Cla ss I va po r b a rrie r o n flo o r, a tta c he d to wa ll, se a ms ta pe d • No ve nts to o utside • Ve nte d c ra wl spa c e • I nsula te flo o r a b o ve 4/7/2015 23

  20. Thermal Requirements INSULATION • Sla b e dg e • Minimum R-15 pe rime te r • F o ur fe e t hig h o r hig h + wide to ta l • He a te d sla b • Minimum R-15 unde rne a th c o ntinuo us • E xpo se d e xte rio r insula tio n must ha ve a pro te c tive c o ve ring 4/7/2015 24

  21. WHAT’S REQUIRED? • Ba sic Re q uire me nts • Pe rfo rma nc e Re q uire me nts -- T hre e Me tho ds  “F a st T ra c k” me tho d  RE S c he c k So ftwa re  Ho me E ne rg y Ra ting • Ce rtific a tio n 4/7/2015 27

  22. WHEN TO DO THE ANALYSIS • No t re q uire d until a fte r, b ut... • Sho uld de te rmine whe re yo u sta nd b e fo re c o mmitting to a de sig n • Or e spe c ia lly, b e fo re fra ming & b a c kfilling 4/7/2015 28

  23. BASIC REQUIREMENTS • Air T ig htne ss • Va po r Re ta rde r • Duc ts • T he rmo sta ts • So lid F ue l Applia nc e s • Ve ntila tio n & Co mb ustio n Air • Windo w U-va lue • Pipe I nsula tio n • L ig hting • E q uipme nt Sizing 4/7/2015 29

  24. Basic Requirements AIR LEAKAGE • Air le a ka g e lo c a tio ns must b e se a le d • Applie s to le a ka g e po ints b e twe e n: • Co nditio ne d spa c e a nd o utside • Co nditio ne d a nd unc o nditio ne d spa c e s • T e sting o ptio n • L e ss tha n 3 ACH @ 50 Pa • E ve rything o pe n e xc e pt c himne y da mpe rs, c o ntinuo usly o pe ra ting ve nt syste m, a djusta b le pa ssive ve nts • Visua l inspe c tio n o ptio n 4/7/2015 31

  25. Basic Requirements VISUAL AIR BARRIER INSPECTION • Co ntinuo us, dura b le a ir b a rrie r • Bre a ks o r jo ints in the a ir b a rrie r se a le d • Spa c e b e twe e n fe ne stra tio n ja mb s a nd fra ming se a le d with minimum e xpa nding fo a m • All plumb ing a nd wiring pe ne tra tio ns sha ll b e se a le d to the a ir b a rrie r 4/7/2015 32

  26. Basic Requirements VISUAL AIR BARRIER INSPECTION • Junc tio ns o f the fo unda tio n a nd sill pla te , sill pla te a nd rim-b a nd, a nd rim b a nd a nd sub flo o r, a nd to ps o f wa lls se a le d • Whe n a ir pe rme a b le insula tio n is insta lle d a t the rim jo ist, a dura b le , rig id inte rio r a ir b a rrie r sha ll b e insta lle d • Air b a rrie r sha ll b e insta lle d a t a ny e xpo se d e dg e o f flo o r insula tio n. 4/7/2015 33

Download Presentation
Download Policy: The content available on the website is offered to you 'AS IS' for your personal information and use only. It cannot be commercialized, licensed, or distributed on other websites without prior consent from the author. To download a presentation, simply click this link. If you encounter any difficulties during the download process, it's possible that the publisher has removed the file from their server.