Infill Code Revisions Cottage Housing, Pocket Residential & Compact Lot Standards November 2, 2017 Community Assembly my.spokanecity.org/projects/ infill-housing-strategies-infill-development/ Background Growing Population


slide-1
SLIDE 1

Infill Code Revisions

Cottage Housing, Pocket Residential & Compact Lot Standards

November 2, 2017 Community Assembly

my.spokanecity.org/projects/ infill-housing-strategies-infill-development/

slide-2
SLIDE 2
  • Growing Population

– Projected 20,000 increase by 2037

  • Housing Shortage

– Rental vacancy under 2% – Single-family housing supply

  • Code Challenges

– Difficult to achieve densities envisioned in Comp Plan

Background

slide-3
SLIDE 3
  • 2016 Infill Task Force

– Multi-disciplinary Steering Committee – Series of Focus Group Meetings

  • Final Report – November, 2016
  • Priorities

– Developable Lands Mapping Tool – Infill Development Education – Land Aggregation Entity – Code Amendments

Infill Task Force

slide-4
SLIDE 4
  • Enable development that achieves Comp

Plan densities

– RSF 4 -10 Dwelling Units per Acre – Increased densities around Centers & Corridors

  • Efficient use of developable lands

– Enable development of smaller, irregularly shaped, or challenging development sites

  • Expanding ownership opportunities
  • Compatibility with existing neighborhood

Code Amendment Goals

slide-5
SLIDE 5
  • Comprehensive Plan Land Use Policy

– Single-family residential areas

  • 4 to 10 units per acre
  • Provisions for alternative processes for

additional housing types

– Public realm

  • Public or private area where people interact

– Efficient use of land in proximity to mixed-use centers and corridors

Adopted Policy

slide-6
SLIDE 6

Adopted Policy

  • Comprehensive Plan

Urban Design Policy

– Design new construction to support desirable behaviors and create a positive perception of Spokane

slide-7
SLIDE 7

1st Phase Infill Code Amendments

  • Compact Residential Lot Standards
  • Pocket Residential Development
  • Cottage Housing
  • Alternative Residential Subdivisions

my.spokanecity.org/projects/infill-housing-strategies-infill-development/

slide-8
SLIDE 8
  • RSF-C Zone provides

compact lot standards

– Reduced front & rear yard setback – Minimum lot size of 3000

  • sq. ft.
  • Within ¼ mile of CC core

land use & transitional sites

  • Requires a rezone

Compact Residential Standards

  • Min. Rear

Setback 25 ft. 15 ft.

  • Min. Lot Width:

40 ft. 36 ft. Example Lot

slide-9
SLIDE 9

Existing RSF- C Eligible Distance – CC Core

RSF zone CC/DT zones

slide-10
SLIDE 10
  • Compact Lot Standards Established for RSF-C

zone (Table 17C.110-3 & SMC 17C.110.209)

  • Apply standards to RSF within ¼ mile of CC

zoning without rezone

  • Apply to transitional sites without a rezone
  • Create a new category “Compact Lot

Standards” in Table 17C.110-3

  • Revise the “applicability” of Compact lot

standards in 17C.110.209(B)

Proposed Changes

slide-11
SLIDE 11

Development Standards Table 17C.110-3

  • p. 9
slide-12
SLIDE 12

Distance from CC zones + CC3 overlays, Compared with CC Core

RSF zone CC/DT zones

slide-13
SLIDE 13

Detached Residences with Frontage on Walkway or Private Access Attached Residences

slide-14
SLIDE 14

Pocket Residential Development

  • Allow some flexibility consistent with

underlying zoning density

  • Where can this tool be used?

– Sites less than 1.5 acres in most residential and commercial zones

Residential Zones Commercial Zones Center & Corridor CC1-4

RA RSF RSF-C RTF RMF RHD O OR NR CB GC

slide-15
SLIDE 15

Pocket Residential Development Allowed outright in Residential Single- family (RSF), or with a conditional use permit, rather than through a zoning change to RSF- Compact (RSF-C).

– Buffer/Transition – Integration into Code

Street Shared Private Access

CONCEPT ILLUSTRATION

Steering Committee Recommendation

slide-16
SLIDE 16
  • Pocket Residential Development -

SMC 17C.110.360 – Proposed amendment to allow in RSF zone (subdivision required) – Only parent site must have street frontage – Enhanced design standards to ensure compatibility with neighborhood – Companion amendment to driveway standards

Pocket Residential Development

slide-17
SLIDE 17

Proposed Changes

Common Driveway Unit Fronting

  • nto a Street

Unit Fronting

  • nto a Private

Street, Drive, or Walkway

slide-18
SLIDE 18
  • Alternative Residential

Subdivisions - SMC

17G.080.065 – Rename “unit lot subdivisions” – Applies to 9 or fewer lots – Align with pocket residential standards – Applies to pocket residential, cottage housing, and similar – Supported by updated driveway standards

Unit Lot Subdivisions

Public sidewalk Internal sidewalk

slide-19
SLIDE 19

Steering Committee Recommendation Cottage Housing should allow for a portion

  • f units with a higher maximum size and the

ability to attach units and mix housing types.

– Location – Buffer/Transition – Past Work and Integration

cottagecompany.com

slide-20
SLIDE 20

Cottage Housing SMC 17C.110.350 What’s not changing:

– Type II conditional use – Overall amount of required open space

Cottage

slide-21
SLIDE 21

Key changes:

– Allow subdivision – New housing types

  • Attached unit homes (up to 2

units)

  • Carriage units (located above

a garage structure)

– Increase floor area to 1,200 sq. ft. – Increase rear setback to 15 feet – Enhanced design standards to improve compatibility

Cottage Attached unit Carriage unit

Cottage Housing SMC 17C.110.350

slide-22
SLIDE 22
  • Requirements (R)

– Must be satisfied by any plan prior to building permit approval. – An applicant may seek a deviation from certain requirements through the design departure process.

  • Presumptions (P)

– Presumptions are guidelines that are meant to be applied, but with some flexibility. – Can be overcome if applicant proposes an alternative that achieves the intent of the presumption.

  • Considerations (C)

– Features and concepts that an applicant should consider in preparing a plan. – May assist in overcoming certain presumptions and in gaining acceptance for a plan.

Cottage Housing Design Guidelines and Standards - SMC 17C.110.350(E)

slide-23
SLIDE 23

Cottage Housing Site Development Standards - SMC 17C.110.350(D)

slide-24
SLIDE 24

Cottage Housing Design Guidelines and Standards - SMC 17C.110.350(E)

slide-25
SLIDE 25

Cottage Housing Design Guidelines and Standards - SMC 17C.110.350(E)

slide-26
SLIDE 26

Cottage Housing Design Guidelines and Standards - SMC 17C.110.350(E)

slide-27
SLIDE 27

Public Participation Events

  • Virtual Open House

– Date TBD

  • Plan Commission workshop

– November 8

  • Plan Commission hearing (tentative)

– December 13

my.spokanecity.org/projects/infill-housing-strategies-infill-development/

slide-28
SLIDE 28
  • Cottage Housing & Pocket Residential

– Oct/Nov Public Outreach – December Plan Commission Hearing – January City Council Hearing & Adoption

  • Dimensional & Transitional Requirements

– Dec/Jan Public Outreach – February Plan Commission Hearing

  • Buildable Area in Hillside Developments

– February Public Outreach

Phase 1 Code Revisions

my.spokanecity.org/projects/infill-housing-strategies-infill-development/