Circuit Solver TM THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS www.CircuitSolver.com Circuit Solver THERMOSTATIC RECIRCULATION VALVE FOR DOMESTIC HOT WATER SYSTEMS TM The Problem The Solution Install a Circuit Solver


slide-1
SLIDE 1

Circuit Solver

TM

THERMOSTATIC RECIRCULATION VALVE

FOR DOMESTIC HOT WATER SYSTEMS

www.CircuitSolver.com

slide-2
SLIDE 2

Therm-Omega-Tech, Inc.

353 IVYLAND ROAD, WARMINSTER, PA 18974-2205 PAGE 2 TEL: 215-674-9992 TOLL FREE: 1-877

  • 379-8258 FAX: 215-674-8594

WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM

Circuit Solver

TM

THERMOSTATIC RECIRCULATION VALVE

FOR DOMESTIC HOT WATER SYSTEMS

The Problem The Solution Design Features

When entering water temperature is below the Circuit Solver™ setpoint, the thermal actuator will begin to open the valve to establish a fmow rate that will achieve the set point. If the water temperature exceeds the set point by 3°F , the valve will begin to throttle back to fjnd the current equilibrium point. Continuously operating at the

  • ptimum temperature minimizes system heat-loss thereby saving energy.

This constant, automatic response to water temperature enables each hot water branch to quickly and consistently deliver the right temperature of hot water to each connected fjxture.

  • Stainless steel body with NPT female connections
  • Meets ANSI/AWWA C800
  • Stainless valve plug, thermal actuator piston and

return spring

  • Complies with California AB1953
  • Thermal actuator develops 40 lbs. of thrust

to keep valve orifjce free of deposits

  • Removable thermal actuator
  • Rated for at least 200,000 cycles
  • NSF-61 Compliant

Water fmows to the path

  • f least resistance.

Many buildings require multiple branches off the hot water supply line. Hot water use is hyper-dynamic, so the path of least resistence constantly changes. Manual fmow control valves cannot effjciently resolve these issues.

1 2 3 4

Install a Circuit Solver™ on each hot water supply branch line immediately downstream of the last runout to a hot tap.

slide-3
SLIDE 3

Therm-Omega-Tech, Inc.

353 IVYLAND ROAD, WARMINSTER, PA 18974-2205 PAGE 3 TEL: 215-674-9992 TOLL FREE: 1-877

  • 379-8258 FAX: 215-674-8594

WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM

Circuit Solver

TM

THERMOSTATIC RECIRCULATION VALVE

FOR DOMESTIC HOT WATER SYSTEMS

Multi-Branch Hot Water Recirculation Diagram Other advantages of installing the Circuit Solver™

EXP. TANK

Z

TMV

Eliminates the need to oversize system recirculating pumps to create constant fmow through manually adjusted balancing valves. Lowers GPM fmow in hot water return lines, minimizing erosion-corrosion problems caused by excessive velocity. Minimizes heat-loss by reducing fmuctuations in average temperature and GPM of the common return line.

1 2 3

With the Circuit Solver™ Thermal Recirculation Valve you get hot water where you need it at every turn of the tap automatically, reliably and economically

slide-4
SLIDE 4

Therm-Omega-Tech, Inc.

353 IVYLAND ROAD, WARMINSTER, PA 18974-2205 PAGE 4 TEL: 215-674-9992 TOLL FREE: 1-877

  • 379-8258 FAX: 215-674-8594

WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM

CIRCUIT SOLVER™ APPLICATION GUIDE

Circuit Solver

TM

THERMOSTATIC RECIRCULATION VALVE

FOR DOMESTIC HOT WATER SYSTEMS

MUL TI-BRANCH COMESTIC HOT WATER SYSTEM

TEMPERED WATER HOT WATER COLD WATER COLD WATER

TMV

SINGLE CONTINUOUS DOMESTIC HOT WATER SUPPL Y LOOP (NO BRANCHES) TO CONSERVE ENERGY

The Circuit Solver™ will modulate fmow to precisely match system heat-loss. Install Circuit Solver™ in the hot water supply line as soon as it becomes a hot water return line (i.e., downstream of the last fjxture served by the hot water supply line). Note: Why use Circuit Solver™ when there are no branch lines?

slide-5
SLIDE 5

Therm-Omega-Tech, Inc.

353 IVYLAND ROAD, WARMINSTER, PA 18974-2205 PAGE 5 TEL: 215-674-9992 TOLL FREE: 1-877

  • 379-8258 FAX: 215-674-8594

WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM

CIRCUIT SOLVER™ APPLICATION GUIDE

Circuit Solver

TM

THERMOSTATIC RECIRCULATION VALVE

FOR DOMESTIC HOT WATER SYSTEMS

From Water Heater To Water Heater

BUILDINGS WITH WIDEL Y SPACED RANDOM FIXTURE LOCATIONS

Install Circuit Solver™ where hot water supply lines randomly interconnect to automatically assure even temperature distribution.

slide-6
SLIDE 6

Therm-Omega-Tech, Inc.

353 IVYLAND ROAD, WARMINSTER, PA 18974-2205 PAGE 6 TEL: 215-674-9992 TOLL FREE: 1-877

  • 379-8258 FAX: 215-674-8594

WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM

CIRCUIT SOLVER™ APPLICATION GUIDE

Circuit Solver

TM

THERMOSTATIC RECIRCULATION VALVE

FOR DOMESTIC HOT WATER SYSTEMS

CIRCUIT SOLVER™ MODEL NUMBER SELECTION

Match the pipe size. Select the desired return water temperature.

1 2

OPTIMUM ACCEPTABLE

INSTALLATION SCHEMATIC

For Example

  • 1. Branch hot water line is 3/4” IPS.
  • 2. Return temperature is 110°F
  • 3. Select Model Number CS-3/4-110

COMMENTS AND CAUTIONS

Circuit Solver™ will evenly distribute hot water temperature to every fjxture as long as hot water is available. However, that cannot happen if...

There is a cross connection joining cold water to hot water. The recirculation pump is not working properly. There is signifjcant pressure differential between the cold and hot water distribution systems.

1 2 3

slide-7
SLIDE 7

Therm-Omega-Tech, Inc.

353 IVYLAND ROAD, WARMINSTER, PA 18974-2205 PAGE 7 TEL: 215-674-9992 TOLL FREE: 1-877

  • 379-8258 FAX: 215-674-8594

WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM

Circuit Solver

TM

THERMOSTATIC RECIRCULATION VALVE

FOR DOMESTIC HOT WATER SYSTEMS

INLET OUTLET Item Description Material 1 Valve Body 303 SS 2 Valve Plug 303 SS 3 Spring Stainless Steel 4 Thermal Actuator 303 SS 5 Carrier 303 SS 6 All Shaded Area Water Passage

Note: The valve plug is shown in the fully open position. As temperature rises, the thermal actuator moves it to the right towards the inlet port to limit fmow to a trickle as temperature exceeds the set point.

GPM@1 PSI Δ P Diameter Length Weight Max Pressure Max Temp Model No. Cv NPT In. In. lbs. PSIG °F CS- ½ -XXX 1.2 ½ 1.13 2.75 0.06 200 300 CS- ¾ -XXX 1.7 ¾ 1.38 3.13 0.07 200 300 CS-1-XXX 3.2 1 1.75 3.38 1.60 200 300 CS-1¼-XXX 5.0 1¼ 2.13 4.60 2.70 200 300 CS-1½-XXX 7.5 1½ 2.38 4.60 3.80 200 300 CS-2-XXX 14.0 2 3.00 4.88 5.60 200 300

Model Number Selection XXX refers to the desired return water temperature. Use that temperature to complete the model number. For example, if you want 110°F return water and the Circuit Solver™ is to be installed on a 3/4” line, the model number would be CS-3/4-110.

6 5 4 3 1 2

slide-8
SLIDE 8

Therm-Omega-Tech, Inc.

353 IVYLAND ROAD, WARMINSTER, PA 18974-2205 PAGE 8 TEL: 215-674-9992 TOLL FREE: 1-877

  • 379-8258 FAX: 215-674-8594

WWW.CIRCUITSOLVER.COM | CS@CIRCUITSOLVER.COM

Circuit Solver

TM

THERMOSTATIC RECIRCULATION VALVE

FOR DOMESTIC HOT WATER SYSTEMS

Resources

Circuit Solver Home Page

www.CircuitSolver.com

Circuit Solver Video

youtu.be/8aDFhWAOhDk

Download This Brochure

http://bit.ly/PgDXi1

Recirculation Pump Guide

http://bit.ly/RcFNTC

Energy Savings Related to Circuit Solver

http://bit.ly/Uzkxdz